Is there a better right-sided tube for one-lung ventilation? A comparison of the right-sided double-lumen tube with the single-lumen tube with right-sided enclosed bronchial blocker



Is there a better right-sided tube for one-lung ventilation? A comparison of the right-sided double-lumen tube with the single-lumen tube with right-sided enclosed bronchial blocker



Anesthesia and Analgesia 86(4): 696-700



Anatomic variation between tracheal canna and the takeoff of the right upper bronchus often makes the use of a right-sided double-lumen tube (R-DLT) or a single-lumen tube with right-sided enclosed bronchial blocker tube (R-UBB) (Univent) undesirable. This study compared the R-DLT with the R-UBB to determine whether there was any advantage of one over the other during anesthesia with one-lung ventilation (OLV) for right-sided thoracic surgeries. Forty patients requiring right lung deflation were randomly assigned to one of two groups. Twenty patients received a right-sided BronchoCath double-lumen tube, and 20 received a Univent tube with a bronchial blocker placed in the tight mainstem bronchus. The following were studied: 1) time required to position each tube until satisfactory placement was achieved; 2) number of times that fiberoptic bronchoscopy was required (including one with the patient supine and one in lateral decubitus position); 3) number of malpositions after initial confirmation of tube placement; 4) time required until lung collapse; 5) surgical exposure; and 6) cost of tubes per case. No differences were found with any of these variables except that the cost of acquisition overall was greater for the R-UBB than for the R-DLT. No right upper lobe collapse was observed in the postoperative period in the chest radiograph in any of the patients studied. We conclude that either tube can be used safely and effectively for right-sided thoracic surgeries that require anesthesia for OLV. Implications: In this study, right-sided double-lumen tubes were compared with the Univent with right-sided bronchial blockers. The results indicate that either tube can be used for right-sided thoracic surgery.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 008921282

Download citation: RISBibTeXText

PMID: 9539585

DOI: 10.1097/00000539-199804000-00003


Related references

Is there a better tube for one lung ventilation? Comparison of the modified bronchocath double-lumen tube vs single-lumen tube with enclosed bronchial blocker. Anesthesiology 85(3A): A424, 1996

Comparison of a modified double-lumen endotracheal tube with a single-lumen tube with enclosed bronchial blocker. Anesthesia and Analgesia 83(6): 1268-1272, 1996

The incidence of right upper-lobe collapse when comparing a right-sided double-lumen tube versus a modified left double-lumen tube for left-sided thoracic surgery. Anesthesia and Analgesia 90(3): 535-540, 2000

A comparison of the deflecting-tip bronchial blocker with a wire-guided blocker or left-sided double-lumen tube. Journal of Cardiothoracic and Vascular Anesthesia 23(4): 501-505, 2009

Efficiency, efficacy, and safety of EZ-blocker compared with left-sided double-lumen tube for one-lung ventilation. Anesthesiology 118(3): 550-561, 2013

Comparison of the double-lumen endotracheal tube and the Arndt bronchial blocker used by inexperienced anesthesiologists in right- and left-sided thoracic surgery. Revista Espanola de Anestesiologia Y Reanimacion 54(10): 602-607, 2008

Comparison of Arndt-endobronchial blocker plus laryngeal mask airway with left-sided double-lumen endobronchial tube in one-lung ventilation in thoracic surgery in the morbidly obese. Brazilian Journal of Medical and Biological Research 51(2): E6825, 2018

Lung isolation in the morbidly obese patient: a comparison of a left-sided double-lumen tracheal tube with the Arndt® wire-guided blocker. British Journal of Anaesthesia 109(4): 630-635, 2012

Selection of an appropriate left-sided double-lumen tube size for one-lung ventilation among Asians. Annals of Cardiac Anaesthesia 20(1): 28-32, 2017

Lung isolation during port-access cardiac surgery: double-lumen endotracheal tube versus single-lumen endotracheal tube with a bronchial blocker. Journal of Cardiothoracic and Vascular Anesthesia 17(6): 725-727, 2003

Bronchial rupture with a left-sided polyvinylchloride double-lumen tube. Acta Anaesthesiologica Scandinavica 47(5): 622-625, 2003

Airway management during anesthesia for double-lung transplantation using a single-lumen endotracheal tube with an enclosed bronchial blocker. Journal of Cardiothoracic and Vascular Anesthesia 6(2): 204-207, 1992

Right bronchial intubation using a left-sided double-lumen tube in a patient with situs inversus. Masui. Japanese Journal of Anesthesiology 56(12): 1411-1413, 2007

Time to tracheal intubation over a fibreoptic bronchoscope using a silicone left double-lumen endobronchial tube versus polyvinyl chloride single-lumen tube with bronchial blocker: a randomized controlled non-inferiority trial. Journal of Thoracic Disease 11(3): 901-908, 2019

Use of a right-sided double lumen tube for lung isolation in a patient with Kartagener's syndrome. Anaesthesia and Intensive Care 44(1): 119-121, 2016