EurekaMag.com logo
+ Site Statistics
References:
53,869,633
Abstracts:
29,686,251
+ Search Articles
+ Subscribe to Site Feeds
EurekaMag Most Shared ContentMost Shared
EurekaMag PDF Full Text ContentPDF Full Text
+ PDF Full Text
Request PDF Full TextRequest PDF Full Text
+ Follow Us
Follow on FacebookFollow on Facebook
Follow on TwitterFollow on Twitter
Follow on LinkedInFollow on LinkedIn

+ Translate

Preliminary experience with the Endovascular Technologies bifurcated endovascular aortic prosthesis in a calf model



Preliminary experience with the Endovascular Technologies bifurcated endovascular aortic prosthesis in a calf model



Journal of Vascular Surgery 22(4): 370-9; Discussion 379-81



Purpose: The purpose of this study was to develop a bifurcated endoluminal prosthesis for transfemoral placement in the aortoiliac position with a large-animal model that would simulate human implantation. Methods: Fifteen calves (160 to 200 kg) underwent bilateral femoral artery exposure and transfemoral placement in the aortoiliac position of a bifurcated Dacron prosthesis, inserted through a 26F sheath with an over-the-bifurcation guide wire to retrieve the contralateral limb and secured proximally and distally with self-expanding attachment systems. The preferred location was determined before implantation and compared with final implant location by caliper measurements and angiography. Events during implantation, maneuvers used to accomplish accurate deployment, and final results, as judged by angiography and clinical evaluation, were recorded. Four animals survived and were used for chronic evaluation and healing by gross and microscopic studies. Results: All grafts (n = 15) were patent at the end of the procedure. AU (n = 7) noncrimped grafts had minor kinks in areas of curvature, whereas eight of eight crimped grafts (device modification) had none. Torque control of the body and individual limbs was necessary to correct twists before deployment in 10 of 15 grafts, with two greater than 30-degree twists remaining, which did not appear to affect flow. One implant was entirely deployed in the aorta because of parallax error, subsequently avoided by use of a marker board placed dorsally. Three premature deployments occurred, corrected by attachment system lock modification. The mean final implant position was within 2.9 +- 1.4 mm (aortic), 1.6 +- 1.1 mm, and 1.5 +- 0.8 mm (contralateral and ipsilateral iliac limbs, respectively) of the intended position. Three of four animals intended for long-term evaluation were killed prematurely because of clinically evident spinal cord ischemia. Histologic sections at 2 weeks showed early wall repair without inflammatory cells and pannus ingrowth across the anastomosis. Conclusion: We conclude that implantation of a bifurcated endovascular prosthesis through the bilateral femoral approach is possible, provided the intended aortic implantation site (neck) is at least 12 mm in length (mean +- 2 SD each direction). Torque control of each portion of the device will be needed in the majority of instances, with attention to parallax effect necessary for optimal placement. This animal model is not suitable for chronic graft evaluation because of its sensitivity for spinal cord ischemia. Healing data suggest graft incorporation similar to that of a surgically placed prosthesis.

(PDF emailed within 1 workday: $29.90)

Accession: 009231888

Download citation: RISBibTeXText

PMID: 7563398



Related references

Immediate and late explantation of endovascular aortic grafts: The endovascular technologies experience. Journal of Vascular Surgery 29(2): 309-316, 1999

Continued expansion of aortic necks after endovascular repair of abdominal aortic aneurysms. EVT Investigators. EndoVascular Technologies, Inc. Journal of Vascular Surgery 28(3): 422-30; Discussion 430-1, 1998

Clinical experience with a bifurcated endovascular graft for abdominal aortic aneurysm repair. Journal Of Vascular Surgery. 24(4): 655-666, 1996

Bifurcated stent-grafts for endovascular repair of abdominal aortic aneurysm. Preliminary case reports. Surgical Endoscopy 8(7): 800-802, 1994

Endovascular aneurysm repair with a bifurcated endovascular graft at a primary referral center: influence of experience, age, gender, and aneurysm size on suitability. Journal of Vascular Surgery 38(4): 758-761, 2003

Seven years' single center experience of Powerlink unibody bifurcated endograft for endovascular aortic aneurysm repair. Journal of Cardiovascular Surgery 48(1): 13-19, 2007

Endovascular reconstruction of the infrarenal abdominal aortic aneurysm--experiences with 3 endovascular stent prosthesis systems. Langenbecks Archiv für Chirurgie. Supplement. Kongressband. Deutsche Gesellschaft für Chirurgie. Kongress 115: 1227-1229, 1999

Clinical consequences of periprosthetic leak after endovascular repair of abdominal aortic aneurysm. Endovascular Technologies Investigators. Journal of Vascular Surgery 27(4): 606-613, 1998

Embolotherapy of persistent endoleaks after endovascular repair of abdominal aortic aneurysm with the ancure-endovascular technologies endograft system. Journal of Vascular and Interventional Radiology 10(9): 1175-1182, 1999

Endovascular split-tube bifurcated graft prosthesis and an implantation method for such a prosthesis. Official Gazette of the United States Patent & Trademark Office Patents 1244(2), Mar 13, 2001

A self-expanding bifurcated endovascular graft for abdominal aortic aneurysm repair. An initial study in a canine model. Asaio Journal 42(5): M386-M393, 1996

Endovascular treatment of endoleaks after endovascular abdominal aortic aneurysm repair: personal experience. La Radiologia Medica 112(3): 409-419, 2007

Endovascular abdominal aortic aneurysm repair with percutaneous transfemoral prostheses deployment under local anaesthesia. Initial experience with a new, simple-to-use tubular and bifurcated device in the first 27 cases. European Journal of Vascular and Endovascular Surgery 17(3): 202-207, 1999

A mathematical model to predict the in vivo pulsatile drag forces acting on bifurcated stent grafts used in endovascular treatment of abdominal aortic aneurysms (AAA). Journal of Biomechanics 37(7): 1087-1095, 2004