Proposed strategies for reducing user error in capillary blood glucose monitoring



Proposed strategies for reducing user error in capillary blood glucose monitoring



Diabetes Care 16(2): 493-498



For individuals with diabetes mellitus, CBGM provides a more accurate picture of daily glucose fluctuation than urine glucose testing (1-9). As a result, CBGM is the preferred method to assess short-term glucose control and provide data for management decisions and insulin adjustment (10-16). Moreover, the wide availability of glucose monitoring systems designed for patient use has made SMBG the standard of care in diabetes management for all capable persons with insulin-requiring diabetes and an appropriate management tool for persons with non-insulin-requiring diabetes (13-20). In spite of the relative accuracy of current CBGM systems in measuring blood glucose levels, a recent study by the FDA suggests that user-procedural errors can cause inaccurate results (21). Inaccurate data affect patients efforts to achieve good metabolic control and, if used as the basis for regimen adjustment, may endanger health (21-42). Therefore, until reliable, technique-free systems are available, the accuracy of data with this technology must be improved through reduction of user error. This article presents strategies to accomplish this goal recommended by a national group of experts, the NSCQA in CBGM.

(PDF emailed within 0-6 h: $19.90)

Accession: 009261044

Download citation: RISBibTeXText

DOI: 10.2337/diacare.16.2.493



Related references

Proposed strategies for reducing user error in capillary blood glucose monitoring. The National Steering Committee for Quality Assurance in Capillary Blood Glucose Monitoring. Diabetes Care 16(2): 493-498, 1993

User's guide for self-monitoring of capillary blood glucose levels. Cmaj 140(1): 25-26, 1989

Clinical and technical evaluation of a new self-monitoring blood glucose meter: Assessment of analytical and user error. Diabetes Research & Clinical Practice 53(2): 121-128, August, 2001

User error in blood glucose monitoring. The National Steering Committee for Quality Assurance Report. Diabetes Care 16(6): 946-948, 1993

Variability of capillary blood glucose monitoring measured on home glucose monitoring devices. Indian Journal of Endocrinology and Metabolism 16(Suppl 2): S248-S251, 2013

No difference between venous and capillary blood sampling and the Minimed continuous glucose monitoring system for determining the blood glucose response to food. Nutrition research 26(8): 403-408, 2006

A comparison between capillary blood sampling and the MinimedReg. Continuous Glucose Monitoring System GoldTM for determining the blood glucose response of foods. Proceedings of the Nutrition Society of New Zealand 30: 71-74, 2005

Self-monitoring of blood glucose: impact of a time delay between capillary blood sampling and glucose measurement. Journal of Diabetes Science and Technology 8(6): 1239-1240, 2015

Performance Evaluation of Three Blood Glucose Monitoring Systems Using ISO 15197: 2013 Accuracy Criteria, Consensus and Surveillance Error Grid Analyses, and Insulin Dosing Error Modeling in a Hospital Setting. Journal of Diabetes Science and Technology 10(1): 85-92, 2016

Accuracy, precision and user-acceptability of self blood glucose monitoring machines. Diabetes Research & Clinical Practice. 36(2): 91-104, 1997

Accuracy and user performance evaluation of a blood glucose monitoring system. Diabetes Technology & Therapeutics 17(3): 152-158, 2015

How well do self-monitored capillary glucose measurements predict the mean blood glucose from 24-hour continuous monitoring in endocrine practice?. Endocrine Practice 20(7): 650-656, 2016

Related importance of user apparatus interaction in home blood glucose monitoring. IRCS (International Research Communications System) Medical Science 13(10): 1021-1022, 1985

Identifying sources of error in self-monitoring of blood glucose. Diabetes Care 11(10): 791-794, 1988