+ Site Statistics
References:
52,654,530
Abstracts:
29,560,856
PMIDs:
28,072,755
+ Search Articles
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ PDF Full Text
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Translate
+ Recently Requested

Tradeoffs between motion and stability in posterior substituting knee arthroplasty design



Tradeoffs between motion and stability in posterior substituting knee arthroplasty design



Journal of Biomechanics 28(10): 1155-1166



The purpose of this study was to examine how changes in component geometry of posterior substituting knees affect tibiofemoral kinematics and prosthesis stability. Most posterior cruciate ligament substituting prostheses rely on an articulation between a femoral cam and tibial spine to provide anterior-posterior stability of the knee. Failure of this ligament substitution mechanism has resulted in knee dislocations with several different posterior substituting designs. A computer model of a generic posterior substituting prosthesis was altered to analyze the effects of five design parameters (tibial spine height, spine anterior-posterior position, femoral component posterior radius, and femoral cam anterior-posterior and distal-proximal position) on prosthesis stability, tibiofemoral kinematics, and maximum obtainable knee flexion. Prosthesis stability was characterized by a 'dislocation safety factor', defined as the vertical distance from the bottom of the femoral can to the top of the tibial spine. Computer simulations revealed that posterior substituting knees are most likely to dislocate at maximum knee flexion. Prosthesis stability can be improved by increasing the tibial spine height and moving the femoral cam posteriorly. Our results suggest there is a tradeoff between maximum knee flexion and prosthesis stability. We found that relatively small gains in maximum knee flexion, made through design changes, may cause substantial decreases in prosthesis stability.

(PDF emailed within 0-6 h: $19.90)

Accession: 009659574

Download citation: RISBibTeXText

PMID: 8550634

DOI: 10.1016/0021-9290(94)00172-z


Related references

Kinematic gait parameters changes in patients after total knee arthroplasty. Comparison between cruciate-retaining and posterior-substituting design. Acta of Bioengineering and Biomechanics 18(3): 137-142, 2016

Anteroposterior translation and range of motion after total knee arthroplasty using posterior cruciate ligament-retaining versus posterior cruciate ligament-substituting prostheses. Knee Surgery, Sports Traumatology, Arthroscopy 25(11): 3536-3542, 2016

High-flexion posterior-substituting versus cruciate-retaining prosthesis in total knee arthroplasty: functional outcome, range of motion and complication comparison. Archives of Orthopaedic and Trauma Surgery 135(1): 119-124, 2015

Changes in femoral posterior condylar offset and knee flexion after PCL-substituting total knee arthroplasty: comparison of anterior and posterior referencing systems. Knee Surgery, Sports Traumatology, Arthroscopy 24(8): 2483-2488, 2015

Similar stability and range of motion between cruciate-retaining and cruciate-substituting ultracongruent insert total knee arthroplasty. Knee Surgery, Sports Traumatology, Arthroscopy 23(6): 1638-1643, 2015

The stability of the cemented tibial component of total knee arthroplasty: posterior cruciate-retaining versus posterior-stabilized design. Journal of Arthroplasty 19(6): 775-782, 2004

In vivo knee kinematics during high flexion after a posterior-substituting total knee arthroplasty. International Orthopaedics 34(4): 497-503, 2010

Posterior cruciate ligament-substituting total knee arthroplasty in young rheumatoid patients with advanced knee involvement. Journal of Arthroplasty 19(1): 49-55, 2004

In vivo Kinematics of the Knee after a Posterior Cruciate-Substituting Total Knee Arthroplasty: A Comparison between Caucasian and South Korean Patients. Knee Surgery & Related Research 28(2): 110-117, 2016

Increase of patellofemoral height has decreased maximum knee flexion after total knee arthroplasty of posterior cruciate-substituting prosthesis in a clinical series. Journal of Orthopaedic Science 21(4): 458-462, 2016

No difference in range of motion between ultracongruent and posterior stabilized design in total knee arthroplasty: a randomized controlled trial. Knee Surgery, Sports Traumatology, Arthroscopy 25(11): 3515-3521, 2016

Fluoroscopic motion study confirming the stability of a medial pivot design total knee arthroplasty. Knee 22(6): 522-526, 2016

Why posterior cruciate-retaining and substituting total knee replacements have similar ranges of motion. The importance of posterior condylar offset and cleanout of posterior condylar space. Journal of Bone and Joint Surgery. American Volume 88 Suppl 4: 182-188, 2006

Posterior cruciate ligament removal contributes to abnormal knee motion during posterior stabilized total knee arthroplasty. Journal of Orthopaedic Research 26(11): 1494-1499, 2008

Posterior cruciate-substituting and -sacrificing total knee arthroplasty. Morrey, B F Reconstructive surgery of the joints, Vols 1 and 2, Second edition: 1409-1416, 1996