+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Vibro-acoustic stimulation in high-risk pregnancies; maternal perception of fetal movements, fetal heart rate and fetal outcome



Vibro-acoustic stimulation in high-risk pregnancies; maternal perception of fetal movements, fetal heart rate and fetal outcome



Journal of Perinatal Medicine 20(4): 267-274



Maternal perception of fetal movement in response to vibro-acoustic stimulation was compared with antenatal fetal heart rate monitoring as a test of fetal well-being in a population of gravidae with high-risk pregnancies (n = 517), admitted to the high-risk ward at Danderyd Hospital, Karolinska Institutet; a total of 2,015 tests were performed. The sensitivity and the specificity of the test compared to the fetal heart rate tracing was 81% and 89% respectively. If the test was performed within 24 hours of delivery, its predictive value for fetal asphyxia (i.e. a 5-minute Apgar score < 7) was 14% (7/49). Ten per cent of the patients felt no fetal movement in response to stimulation (irrespective of gestational age). In five cases where fetal heart rate tracings were pathological, stimulation nonetheless produced fetal movement and fetal outcome was good. Pathological heart rate tracings and no fetal movement in response to stimulation were present in 30 cases (out of 251 with no fetal movements at stimulation), in seven of which the infants had 5-minute Apgar scores < 7. Although many patients underwent repeated vibro-acoustic stimulation, there was no evidence of fetal habituation to the test. On 24 occasions (i.e. 1.2%), the patient denied vibro-acoustic stimulation, mostly because of previous discomfort due to vigorous fetal response. Where resources are limited, maternal perception of fetal movements in response to vibro-acoustic stimulation might be a useful alternative for preliminary screening of high-risk pregnancies.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 009723985

Download citation: RISBibTeXText

PMID: 1432550

DOI: 10.1515/jpme.1992.20.4.267


Related references

Fetal vibro-acoustic stimulation: magnitude and duration of fetal heart rate accelerations as a marker of fetal health. Obstetrics and Gynecology 72(4): 621-626, 1988

Hourly fetal urinary production rate and blood velocity waveforms in the fetal renal artery relative to fetal heart rate pattern and fetal eye movements in normal pregnancies at 30-32 weeks of gestation. Early Human Development. 38(1): 27-34, 1994

Abnormal antepartum fetal heart rate in high risk pregnancies with good fetal outcome. Asia-Oceania Journal of Obstetrics and Gynaecology 14(3): 267-273, 1988

Demonstration of fetal habituation and patterns of fetal heart rate response to vibroacoustic stimulation in normal and high-risk pregnancies. Journal of Perinatology 11(1): 25-29, 1991

Effects of maternal cigarette smoking on fetal trunk movements fetal breathing movements and the fetal heart rate. British Journal of Obstetrics & Gynaecology 91(7): 657-661, 1984

Vibro-acoustic stimulation does not alter the duration of high and low fetal heart rate variability episodes. Journal of Perinatal Medicine 20(5): 331-336, 1992

Fetal heart rate patterns and vibro acoustic stimulation in labor. Archives of Gynecology 237(Suppl.): 56-57, 1985

Clinical experience with the Hewlett-Packard M-1350A fetal monitor: Correlation of Doppler-detected fetal body movements with fetal heart rate parameters and perinatal outcome. American Journal of Obstetrics and Gynecology 170(2): 650-655, 1994

Intrapartum fetal heart rate responses to vibroacoustic stimulation versus fetal blood pH studies to predict fetal outcome in labor. American Journal of Obstetrics & Gynecology 180(1 Part 2): S91, 1999

The clustering of fetal heart rate changes and fetal movements in pregnancies between 20 and 30 weeks of gestation. American Journal of Obstetrics and Gynecology 143(8): 952-957, 1982

Fetal heart rate accelerations and fetal movements in twin pregnancies. American Journal of Obstetrics & Gynecology 152(6 Part 1): 686-687, 1985

The association between fetal heart rate patterns and fetal movements in pregnancies between 20 and 30 weeks' gestation. American Journal of Obstetrics and Gynecology 143(3): 243-249, 1982

Maternal perception of sound-provoked fetal movements in low-risk pregnancies during the third trimester. British Journal of Obstetrics and Gynaecology 96(5): 566-567, 1989

Influence of maternal heart rate and gross fetal body movements on the daily pattern of fetal heart rate near term. American Journal of Obstetrics and Gynecology 144(5): 533-538, 1982

Maternal Self-administered Fetal Heart Rate Monitoring and Transmission From Home in High-Risk Pregnancies. Yearbook of Obstetrics Gynecology and Women's Health 2006: 113-114, 2006