+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Cardiac rhythm disturbances in the obstructive sleep apnea syndrome: effects of nasal continuous positive airway pressure therapy



Cardiac rhythm disturbances in the obstructive sleep apnea syndrome: effects of nasal continuous positive airway pressure therapy



Chest 118(3): 591-595



Study objectives: A high incidence of nocturnal cardiac rhythm disturbances among patients with obstructive sleep apnea (OSA) syndrome has been described in some reports, but not in others. We wished to examine the prevalence of significant cardiac rhythm disturbance in patients with established moderate to severe OSA syndrome and, in particular, to assess the impact of nasal continuous positive airway pressure (nCPAP) therapy. Design and setting: A prospective study of consecutive eligible patients in a dedicated sleep disorders unit of a university teaching hospital. Measurements and results: Holter monitoring was performed for 18 h in 45 patients with previously diagnosed OSA syndrome (mean (SD) apnea/hypopnea frequency (AHI) of 50 (23)/h) and repeated within 2 to 3 days after institution of nCPAP therapy. Investigators were blinded to the patients' treatments during data analysis. Thirty-five patients were found to have some cardiac rhythm disturbance, but only 8 had pathologically significant disturbances (ventricular tachycardia or fibrillation, complex ventricular, ectopy, new-onset supraventricular tachycardia other than sinus tachycardia, pauses of > 2 s, and second- or third-degree heart block). Significant rhythm disturbances occurred only during the nighttime, and there was a significant correlation between OSA severity and the severity of rhythm disturbance (p = 0.04, r = 0.301). No significant correlation was found between OSA severity and any other anthropometric parameter measured. nCPAP therapy resulted in abolition of rhythm disturbance in seven of these eight patients; the eighth patient was found to have coexisting severe aortic valve disease requiring valve replacement. Conclusion: The data indicate that OSA syndrome predisposes to clinically significant cardiac rhythm disturbances that can be successfully controlled by nCPAP therapy.

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 010277249

Download citation: RISBibTeXText

PMID: 10988177


Related references

Cardiac disturbances in patients with obstructive sleep apnea effect of nasal continuous positive airway pressure. American Journal of Noninvasive Cardiology 6(1): 47-54, 1992

Effect of nasal continuous positive airway pressure on nighttime and daytime cardiac disturbances in obstructive sleep apnea. American Review of Respiratory Disease 141(4 Part 2): A864, 1990

Effects of nasal continuous positive airway pressure therapy on respiratory parameters of upper airway patency in patients with obstructive sleep apnea syndrome. Chest 114(3): 691-696, 1998

Impact of nasal continuous positive airway pressure on heart rhythm in patients with obstructive sleep apnea/hypopnea syndrome. Minerva Medica 105(3): 255-260, 2014

Effects of long-term nasal continuous positive airway pressure therapy on morphology, function, and mucociliary clearance of nasal epithelium in patients with obstructive sleep apnea syndrome. Laryngoscope 114(8): 1431-1434, 2004

Nasal continuous positive airway pressure therapy in obstructive sleep apnea syndrome. Zhonghua Jie he He Hu Xi Za Zhi 14(4): 225-7 256, 1991

Histology of nasal mucosa in untreated obstructive sleep apnea syndrome and during nasal continuous positive airway pressure therapy. FASEB Journal 16(4): A359-A360, 2002

Nasal continuous positive airway pressure therapy of obstructive sleep apnea syndrome Effects on rhinoflow, mucosal surface temperature and water loss. FASEB Journal 16(5): A1148, 2002

Daytime sleepiness and nasal continuous positive airway pressure therapy in obstructive sleep apnea syndrome patients: Effects of chronic treatment and 1-night therapy withdrawal. Sleep 18(3): 195-201, 1995

Effects of nasal continuous positive airway pressure on patients with obstructive sleep apnea syndrome. Journal of the Formosan Medical Association 90(3): 296-299, 1991

The immediate effects of nasal continuous positive airway pressure treatment on sleep pattern in patients with obstructive sleep apnea syndrome. Electroencephalography & Clinical Neurophysiology 63(1): 10-17, 1986

Therapy with nasal CPAP (continuous positive airway pressure) in patients with obstructive sleep apnea syndrome (OSAS). II: Side-effects of nCPAP therapy. Effect on long-term acceptance. Laryngo- Rhino- Otologie 76(10): 608-613, 1998

Nasal continuous positive airway pressure (CPAP) therapy for obstructive sleep apnea in Hallermann-Streiff syndrome. Clinical Pediatrics 29(2): 122-124, 1990

Effects of nasal obstruction on continuous positive airway pressure treatments in obstructive sleep apnea syndrome. Sleep and Biological Rhythms 2(1): 89-91, 2004

The effects of nasal continuous positive airway pressure on platelet activation in obstructive sleep apnea syndrome. Chest 125(5): 1768-1775, 2004