Clinical and technical evaluation of a new self-monitoring blood glucose meter: Assessment of analytical and user error



Clinical and technical evaluation of a new self-monitoring blood glucose meter: Assessment of analytical and user error



Diabetes Research & Clinical Practice 53(2): 121-128, August



Our study aimed to validate (against the standards of the American Diabetes Association and the International Organization for Standardization) the analytical and clinical accuracy of the new MediSense Precision Plus Electrodes on the QID system when compared with a reference method using the Abbott Vision glucose analyzer. Previous studies have shown that the overall accuracy of the device also depends on the proficiency of the operator, so we also assessed the 'ease of use' of the MediSense system, by comparing the results obtained by the patient and health care professional. Accuracy of the self-monitored blood glucose measurements was evaluated over a wide range of glucose readings (2.6-20.0 mmol/l). Between-run CVs (using the manufacturer's quality control material) were found to be 7% at 2.7 mmol/l and 4.8% at 15.5 mmol/l (n=380). We used the error-grid analysis with target range blood glucose, then separated the data into different subsets. We found that 100% of all measurements were in the clinically acceptable zones of A and B. All measured values of the MediSense QID system complied with the requirements for 'blood glucose monitoring meters', as proposed by the International Organization for Standardization. The rating of the patient questionnaire showed a good to very good overall rating and acceptance with a short instruction time. The results indicate that that the MediSense QID/Precision Plus Electrodes is a reliable and easy to use device, which can be recommended for the majority of patients with diabetes mellitus.

(PDF emailed within 0-6 h: $19.90)

Accession: 010328795

Download citation: RISBibTeXText

PMID: 11403861

DOI: 10.1016/s0168-8227(01)00248-0



Related references

Estimating maximum allowable analytical error in whole blood glucose meter measurements from meter downloads of 35 former-DCCT study. Clinical Chemistry 44(6 PART 2): A156, June, 1998

Effect of ambient temperature on analytical and clinical performance of a blood glucose monitoring system: Omnitest Sensor glucose meter. Annals of Clinical Biochemistry 38(Pt 6): 676-683, 2001

Technical and clinical evaluation of the exact tech blood glucose meter. Diabetologia 33(SUPPL): A118, 1990

Evaluation of clinical and analytical accuracy of a new home blood glucose meter Glucomen. Clinical Chemistry & Laboratory Medicine 37(SPEC SUPPL ): S382, June, 1999

Proposed strategies for reducing user error in capillary blood glucose monitoring. The National Steering Committee for Quality Assurance in Capillary Blood Glucose Monitoring. Diabetes Care 16(2): 493-498, 1993

Technical and clinical accuracy of three blood glucose meters: clinical impact assessment using error grid analysis and insulin sliding scales. Journal of Clinical Pathology 69(10): 899-905, 2016

Technical and clinical accuracy of five blood glucose meters: clinical impact assessment using error grid analysis and insulin sliding scales. Journal of Clinical Pathology 68(9): E3-E3, 2015

Proposed strategies for reducing user error in capillary blood glucose monitoring. Diabetes Care 16(2): 493-498, 1993

User error in blood glucose monitoring. The National Steering Committee for Quality Assurance Report. Diabetes Care 16(6): 946-948, 1993

Analytical Performance Evaluation of Infopia Elementâ„¢ Auto-coding Blood Glucose Monitoring System for Self-Monitoring of Blood Glucose. Journal of Clinical Laboratory Analysis 30(6): 849-858, 2016

New approach to technical and clinical evaluation of devices for self-monitoring of blood glucose. Diabetes Care 11(8): 619-629, 1988

Advanced meter features improve postprandial and paired self-monitoring of blood glucose in individuals with diabetes: results of the Actions with the CONTOUR Blood Glucose Meter and Behaviors in Frequent Testers (ACT) study. Diabetes Technology & Therapeutics 14(10): 851-857, 2013

Analytical evaluation of the Optium Xido blood glucose meter. Clinical Chemistry and Laboratory Medicine 46(1): 143-147, 2007

Evaluation of the analytical performance of the coulometry-based Optium Omega blood glucose meter. Journal of Diabetes Science and Technology 5(6): 1612-1617, 2012