EurekaMag.com logo
+ Site Statistics
References:
53,869,633
Abstracts:
29,686,251
+ Search Articles
+ Subscribe to Site Feeds
EurekaMag Most Shared ContentMost Shared
EurekaMag PDF Full Text ContentPDF Full Text
+ PDF Full Text
Request PDF Full TextRequest PDF Full Text
+ Follow Us
Follow on FacebookFollow on Facebook
Follow on TwitterFollow on Twitter
Follow on LinkedInFollow on LinkedIn

+ Translate

Crossover study of three methods for low-level white blood cell counting on two types of flow cytometer



Crossover study of three methods for low-level white blood cell counting on two types of flow cytometer



Cytometry. Part B, Clinical Cytometry 54(1): 39-45



Background: Flow cytometric methods were previously shown to be preferable to microscopic and volumetric methods for counting residual white blood cells (WBCs). In this study, three flow cytometric, low-level WBC counting methods were cross compared using two flow cytometers. Methods: Double-filtered red cell and platelet concentrates were spiked with different amounts of WBC to obtain panels of unspiked and 0.3, 1.0, 3.3, and 10.0 WBC/mul. The methods of BD Biosciences (BDB), Beckman-Coulter (BC), and an in-house method were performed on flow cytometers from BDB and BC. Samples were measured in ninefold. We required that (a) r2 be at least 0.98 (linearity), (b) at least 80% of observations fell within 20% of expected values (accuracy), and (c) the coefficients of variation be at least 20% (precision) for samples containing at least 3.3 WBC/mul. Results: For the red cell panel, our requirements were met by the BDB method on both flow cytometers and by the BC and in-house methods on the BDB flow cytometer only. For the platelet panel, our requirements were met on all combinations of methods and flow cytometers, except for the in-house method on the BDB flow cytometer. Intra-assay variation was lowest for the BDB method, irrespective of the type of flow cytometer used. Conclusion: Based on accuracy and precision, the BDB method on the BDB flow cytometer produced the best results for counting low-level WBCs.

(PDF emailed within 0-6 h: $19.90)

Accession: 010398042

Download citation: RISBibTeXText

PMID: 12827666

DOI: 10.1002/cyto.b.10015



Related references

Blood T-cell quantitation Comparison of the three color methods of the Coulter XL flow cytometer/multiprep and the Becton Dickinson FACScan flow cytometer/FACSlyse systems. American Journal of Clinical Pathology 101(3): 397, 1994

White blood cell differentiation using a solid state flow cytometer. Cytometry 14(6): 589-594, 1993

Counting and differentiation of blood corpuscles with a simple flow cytometer. Zeitschrift für Medizinische Laboratoriumsdiagnostik 30(2): 128-131, 1989

Multicenter evaluation of two flow cytometric methods for counting low levels of white blood cells. Transfusion 44(9): 1319-1324, 2004

Evaluation of an easy and affordable flow cytometer for volumetric haematopoietic stem cell counting. Blood Transfusion 12(3): 416-420, 2015

Flow cytometer nozzle and flow cytometer sample handling methods. Official Gazette of the United States Patent & Trademark Office Patents 1248(4), July 24, 2001

Low propidium iodide intensity in flow cytometric white blood cell counting as a marker of cell destruction?. Transfusion 45(2): 228-233, 2005

Hematology: automated white blood cell differential counting flow-analysis. Clinics in Laboratory Medicine 1(1): 127-150, 1981

Flow cytometric white blood cell differential using CytoDiff is excellent for counting blasts. Annals of Laboratory Medicine 35(1): 28-34, 2016

A comparative study of the white blood cell pipette method and the makler counting chamber method of counting spermatozoa. South African Medical Journal 58(13): 536-538, 1980

Determination of Stent Frame Displacement After Endovascular Aneurysm Sealing. Journal of Endovascular Therapy 1526602817745513-1526602817745513, 2017

A rapid high-precision flow cytometry based technique for total white blood cell counting in chickens. Veterinary Immunology and Immunopathology 145(1-2): 86-99, 2012

Platelet counting with the BD Accuri(TM) C6 flow cytometer. Platelets 25(3): 175-180, 2015

Comparative study of differential white cell counting with histochemical hemalog d and morphological methods. Israel Journal of Medical Sciences 13(4): 444-445, 1977

Reducing costs in flow-cytometric counting of residual white blood cells in blood products: utilization of a single-platform bead-free flow-rate calibration method. Transfusion 51(7): 1431-1438, 2011