Effect of ambient temperature on analytical and clinical performance of a blood glucose monitoring system: Omnitest Sensor glucose meter



Effect of ambient temperature on analytical and clinical performance of a blood glucose monitoring system: Omnitest Sensor glucose meter



Annals of Clinical Biochemistry 38(Pt 6): 676-683



The effect of ambient temperature on the analytical and clinical performance of a glucose meter was examined. A total of 114 venous whole blood samples were analysed for glucose by a reference method, and by a glucose meter at 21-22 degrees C, room temperatures, 26-27 degrees C and 33-34 degrees C. Glucose meter readings at each temperature were compared with the reference values and evaluated by analysis of variance, Spearman's correlation, the percentage of glucose meter readings within +/- 10% of the reference value and error grid analysis. Analysis of covariance was used to determine the effect of temperature on glucose meter readings. There were no significant differences in the glucose meter readings and in accuracy of the meter readings between different temperatures. Temperature was not a significant independent determinant of the glucose meter readings. For each glucose concentration, the precision of the meter and clinical performance were comparable between the different temperatures. In conclusion, ambient temperature does not affect the accuracy, precision and clinical performance of the Omnitest Sensor.

(PDF emailed within 0-6 h: $19.90)

Accession: 010516633

Download citation: RISBibTeXText

PMID: 11732650

DOI: 10.1258/0004563011901091



Related references

Effect of ambient temperature on analytical performance of self-monitoring blood glucose systems. Diabetes Technology & Therapeutics 13(9): 883-892, 2012

Analytical Performance Evaluation of Infopia Elementâ„¢ Auto-coding Blood Glucose Monitoring System for Self-Monitoring of Blood Glucose. Journal of Clinical Laboratory Analysis 30(6): 849-858, 2016

Performance of FreeStyle navigator against standards for continuous glucose monitoring systems and ISO15197 system accuracy blood glucose meter guidelines. 2007

How Should Blood Glucose Meter System Analytical Performance Be Assessed?. Journal of Diabetes Science and Technology 10(1): 178-184, 2016

Analytical performance of glucose monitoring systems at different blood glucose ranges and analysis of outliers in a clinical setting. Journal of Diabetes Science and Technology 8(3): 466-472, 2015

Clinical and technical evaluation of a new self-monitoring blood glucose meter: Assessment of analytical and user error. Diabetes Research & Clinical Practice 53(2): 121-128, August, 2001

Effects of simulated altitude on blood glucose meter performance: implications for in-flight blood glucose monitoring. Journal of Diabetes Science and Technology 6(4): 867-874, 2013

A glucose monitoring system for on line estimation in man of blood glucose concentration using a miniaturized glucose sensor implanted in the subcutaneous tissue and a wearable control unit. Diabetologia. 36(7): 658-663, 1993

Calibration in dogs of a subcutaneous miniaturized glucose sensor using a glucose meter for blood glucose determination. Biosensors & Bioelectronics 7(8): 587-592, 1992

Influence of ambient temperature on the correlation between self-monitoring of blood glucose and plasma glucose values in diabetes management. Journal of Primary Health Care 4(4): 294-298, 2013

The effect on blood glucose levels of low temperature measured by home glucose monitoring system. Journal of the Japan Diabetes Society 29(7): 639-642, 1986

Advanced meter features improve postprandial and paired self-monitoring of blood glucose in individuals with diabetes: results of the Actions with the CONTOUR Blood Glucose Meter and Behaviors in Frequent Testers (ACT) study. Diabetes Technology & Therapeutics 14(10): 851-857, 2013

2008 resource guide. Blood glucose monitoring and data management systems. Before you buy a blood glucose monitor (also known as a blood glucose meter), check with your doctor and diabetes educator. Make sure the one you choose is well suited to your particular needs. Diabetes Forecast 61(1): Rg31-2, Rg34-48, 2008

Comparison of a continuous glucose monitoring system with a portable blood glucose meter to determine insulin dose in cats with diabetes mellitus. Journal of Veterinary Internal Medicine 25(5): 1084-1088, 2012

Clinical performance of the TRUE2go blood glucose system--a novel integrated system for meter and strips. Diabetes Technology & Therapeutics 11(10): 649-655, 2010