+ Site Statistics
References:
52,654,530
Abstracts:
29,560,856
PMIDs:
28,072,755
+ Search Articles
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ PDF Full Text
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Translate
+ Recently Requested

Effects of active compression-decompression cardiopulmonary resuscitation with the inspiratory threshold valve in a young porcine model of cardiac arrest



Effects of active compression-decompression cardiopulmonary resuscitation with the inspiratory threshold valve in a young porcine model of cardiac arrest



Pediatric Research 51(4): 523-527



Active compression-decompression (ACD) cardiopulmonary resuscitation (CPR) with the inspiratory threshold valve (ITV) has been recently recommended by the American Heart Association for treatment of adults in cardiac arrest (class IIb: alternative, useful intervention), but this new technique has never been used in a pediatric population. Thus, this study was designed to evaluate ACD + ITV CPR in a young porcine model of cardiac arrest. After 10 min of ventricular fibrillation, and 8 min of standard CPR, ACD + ITV CPR was performed in seven 4- to 6-wk-old pigs (8-12 kg); defibrillation was attempted 8 min later. Within 2 min after initiation of ACD + ITV CPR, mean (+/- SEM) coronary perfusion pressure increased from 18 +/- 2 to 24 +/- 3 mm Hg (p = 0.018). During standard versus ACD + ITV CPR, mean left ventricular myocardial and total cerebral blood flow was 59 +/- 21 versus 126 +/- 32 mL.min(-1).100 g(-1), and 36 +/- 7 versus 60 +/- 15 mL.min(-1).100 g(-1), respectively (p = 0.028). Six of seven animals were successfully defibrillated, and survived >15 min. In conclusion, the combination of ACD + ITV CPR significantly increased both coronary perfusion pressure and vital organ blood flow after prolonged standard CPR in this young porcine model of ventricular fibrillation.

(PDF emailed within 0-6 h: $19.90)

Accession: 010544077

Download citation: RISBibTeXText

PMID: 11919340

DOI: 10.1203/00006450-200204000-00020


Related references

Vasopressor response in a porcine model of hypothermic cardiac arrest is improved with active compression-decompression cardiopulmonary resuscitation using the inspiratory impedance threshold valve. Anesthesia & Analgesia 95(6): 1496-1502, December, 2002

Comparison of standard cardiopulmonary resuscitation versus the combination of active compression-decompression cardiopulmonary resuscitation and an inspiratory impedance threshold device for out-of-hospital cardiac arrest. Circulation 108(18): 2201-2205, 2003

Rapid induction of cerebral hypothermia is enhanced with active compression-decompression plus inspiratory impedance threshold device cardiopulmonary resusitation in a porcine model of cardiac arrest. Journal of the American College of Cardiology 47(4): 835-841, 2006

Combined active compression-decompression cardiopulmonary resuscitation and inspiratory impedance threshold devices may improve survival after out-of-hospital cardiac arrest. Cardiology Journal 18(2): 207-209, 2013

The effects of positive end-expiratory pressure during active compression decompression cardiopulmonary resuscitation with the inspiratory threshold valve. Anesthesia and Analgesia 92(4): 967-974, 2001

Improving active compression decompression cardiopulmonary resuscitation with an impedance threshold valve in patients in cardiac arrest. Circulation 98(17 SUPPL ): I477, Oct 27, 1998

Improving standard cardiopulmonary resuscitation with an inspiratory impedance threshold valve in a porcine model of cardiac arrest. Anesthesia and Analgesia 93(3): 649-655, 2001

Comparison of an active versus sham impedance threshold valve on survival in patients receiving active compression decompression cardiopulmonary resuscitation for out-of-hospital cardiac arrest. Circulation 104(17 Supplement): II 765, October 23, 2001

A comparison of standard cardiopulmonary resuscitation and active compression-decompression resuscitation for out-of-hospital cardiac arrest. French Active Compression-Decompression Cardiopulmonary Resuscitation Study Group. New England Journal of Medicine 341(8): 569-575, 1999

Inspiratory impedance during active compression-decompression cardiopulmonary resuscitation: a randomized evaluation in patients in cardiac arrest. Circulation 101(9): 989-994, 2000

Head and thorax elevation during active compression decompression cardiopulmonary resuscitation with an impedance threshold device improves cerebral perfusion in a swine model of prolonged cardiac arrest. Resuscitation 121: 195-200, 2017

Improved cerebral perfusion pressures and 24-hr neurological survival in a porcine model of cardiac arrest with active compression-decompression cardiopulmonary resuscitation and augmentation of negative intrathoracic pressure. Critical Care Medicine 40(6): 1851-1856, 2012

Treatment of non-traumatic out-of-hospital cardiac arrest with active compression decompression cardiopulmonary resuscitation plus an impedance threshold device. Resuscitation 84(9): 1214-1222, 2014

Evaluation of an impedance threshold device in patients receiving active compression-decompression cardiopulmonary resuscitation for out of hospital cardiac arrest. Resuscitation 61(3): 265-271, 2004

Use of an inspiratory impedance threshold device on a facemask and endotracheal tube to reduce intrathoracic pressures during the decompression phase of active compression-decompression cardiopulmonary resuscitation. Critical Care Medicine 33(5): 990-994, 2005