Image quality of digital rotational panoramic x-ray imaging system with charge-coupled device sensor. Comparisons with conventional analog image



Image quality of digital rotational panoramic x-ray imaging system with charge-coupled device sensor. Comparisons with conventional analog image



Shikwa Gakuho 100(10): 977-991



Image quality in digital rotational panoramic radiography using a charge-coupled device sensor was compared with conventional analog radiograph. The panoramic x-ray machine used in this study was a Veraviewepocs (J. Morita Co.), which is available for both digital and analog radiography. For each of them, the central plane and the focal trough were determined visually using a phantom made of steel spheres. The signal detection rates with digital and analog images were compared using aluminum test objects. Scores for the image clarity of 6 anatomical landmarks in panoramic images of a head phantom were also compared. Both phantoms were exposed at a tube current varying from 1 to 9 mA. The central plane and the focal trough in digital and analog radiography were almost identical. The signal detection rates and the scores for image clarity with the digital image increased gradually with the increase in the tube current, whereas those with the analog image increased markedly. The digital image showed significantly higher detection rates below the tube current of 5mA. Above 7mA, the rates of both images became comparable. The digital image also showed higher scores for image clarity below the tube current of 3mA. Above 5mA, higher scores were obtained with the analog image. However, the scores of the digital image were sufficiently high and no significant difference was found in almost all landmarks. Therefore, it can be concluded that a digital image can produce an identical diagnostic accuracy to an analog radiograph, with a half radiation exposure.

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 010792005

Download citation: RISBibTeXText


Related references

Distortion within the image layer of a panoramic radiographic system using a charge-coupled device receptor Experiences with the DigiPan. Farman, A G , Ruprecht, A , Gibbs, S J , Scarfe, W C International Congress Series; IADMFR/CMI'97 Advances in maxillofacial imaging : 283-290, 1997

Evaluation of CRT-displayed and printout image quality in digital rotational panoramic radiography system Comparison between images obtained by the Orthophos DS CCD-based digital radiography system and analogue images on film. Shikwa Gakuho 100(9): 833-842, 2000

Analysis on the Effect of Sensor Views in Image Reconstruction Produced by Optical Tomography System Using Charge-Coupled Device. IEEE Transactions on Image Processing 27(4): 1689-1696, 2018

The subjective image quality of direct digital and conventional panoramic radiography. Clinical Oral Investigations 4(3): 162-167, 2000

The comparison of subjective image quality in conventional and digital panoramic radiography. Indian Journal of Dental Research 20(1): 21-25, 2009

A comparison of image characteristics and convenience in panoramic radiography using charge-coupled device, storage phosphor, and film receptors. Journal of Digital Imaging 14(2 Suppl 1): 48-51, 2001

The subjective image quality of conventional and digital panoramic radiography among 6 to 10 year old children. Journal of Clinical Pediatric Dentistry 31(2): 109-112, 2007

Image quality assessment in panoramic dental radiography: a comparative study between conventional and digital systems. Quantitative Imaging in Medicine and Surgery 3(1): 43-48, 2013

Two-dimensional polarimeter with a charge-coupled-device image sensor and a piezoelastic modulator. Applied Optics 33(19): 4254-4260, 1994

Charge-coupled device image sensor as a demodulator in a 2-D polarimeter with a piezoelastic modulator. Applied Optics 29(8): 1186-1190, 1990

The loss of image quality in digital panoramic radiography using image compression. Farman, A G, Ruprecht, A, Gibbs, S J, Scarfe, W C International Congress Series; IADMFR/CMI'97 Advances in maxillofacial imaging: 299-305, 1997

Digital slot-scan charge-coupled device radiography versus AMBER and Bucky screen-film radiography: comparison of image quality in a phantom study. Radiology 235(3): 857-866, 2005

A comparative study of image quality and radiation exposure for dental radiographs produced using a charge-coupled device and a phosphor plate system. International Endodontic Journal 42(10): 900-907, 2009

Evaluation of CRT-displayed and printout image quality in digital rotational panoramic radiography system Comparison between images obtained by the Combi-X and Paxorama2000 computed radiography systems and analogue images on film, and effects of unsharp masking filter. Shikwa Gakuho 100(9): 843-857, 2000

A comparison of panoramic image quality between a digital radiography storage phosphor system and a film-based system. Journal of Contemporary Dental Practice 11(1): E009-E016, 2010