+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Lack of effect of small high-dose volumes on the dose-response relationship for the development of fibrosis in distant parts of the ipsilateral lung in mini-pigs



Lack of effect of small high-dose volumes on the dose-response relationship for the development of fibrosis in distant parts of the ipsilateral lung in mini-pigs



International Journal of Radiation Biology 76(4): 477-485



Purpose: Multi-field radiation therapy for intrathoracic tumours results in a heterogeneous dose distribution in lung tissue. This study investigated whether irradiation of small lung volumes with high fibrogenic doses affects the dose-response relationship for development of fibrosis in distant parts of the ipsilateral lung of mini-pigs. Materials and methods: The whole right lung of 26 'Mini-Lewe' pigs was irradiated with homogeneous doses of between 25 Gy and 40 Gy given in five equal fractions using opposing anterior-posterior portals and a linear accelerator. Another 32 animals were irradiated with a constant dose of 35 Gy to a small house-shaped high-dose field (base 3.0 cm, height 4 cm) located 3 cm caudolateral to the right hilus, while the surrounding right lung received either no irradiation or homogeneous doses of between 20 Gy and 30 Gy. The radiation fields were simulated and port films were obtained for each of the 10 fields in all pigs. Fibrosis was quantified 9 months after irradiation by determination of the hydroxyproline (HP) content of the 32 high-dose volumes and in the lung apex and the basolateral lung of all 58 pigs. Based on the reference value for the HP-ratio, i.e. the HP-concentration of the right lung over the left lung, obtained in 12 unirradiated control animals, the experimental results were converted into quantal data for probit analysis, a responder being an animal with an HP-ratio > 1.33. Results: A dose-response relationship for the HP-ratio was obtained in the different lung sites and irradiation groups. For a given dose level the mean HP-ratios and response rates did not differ systematically between the lung apex and the basolateral lung. Probit analysis of the pooled data produced ED50 values of 21.8 Gy (95% CI 12-37) for irradiation without a high-dose volume and 25.9 Gy (24-28) for irradiation with a high-dose volume. These values are not significantly different. The results from both irradiation groups could be well fitted by a common dose-response curve with an ED50 value of 26.1 Gy. Unexpectedly, the response rates in the high-dose volume increased with increasing dose to the surrounding right lung. Analysis of the port films provided an explanation for this finding: inaccuracies in daily field positioning. When this error was corrected for by use of the mean dose to the high-dose volume, a dose-response curve with an ED50 of 25.2 Gy (22-29) was determined for the high-dose volume. Conclusions: The results of the study indicate that the irradiation of a small lung volume with high fibrogenic doses does not affect the dose-response relationship for development of fibrosis in distant parts of the ipsilateral lung.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 010906680

Download citation: RISBibTeXText

PMID: 10815627

DOI: 10.1080/095530000138475


Related references

Steep Holm wildlife. Unknown, 1990

Radiotherapy in Conjunction with 7-Hydroxystaurosporine: A Multimodal Approach with Tumor pO2 as a Potential Marker of Therapeutic Response. Radiation Research 172(5): 592-597, 2009

In vivo assessment of coronary stents with 64-row multidetector computed tomography: analysis of metal artifacts. Journal of Computer Assisted Tomography 34(6): 921-926, 2010

Dosimetric analysis of organs at risk during expiratory gating in stereotactic body radiation therapy for pancreatic cancer. International Journal of Radiation Oncology Biology Physics 85(4): 1090-1095, 2013

A randomized study of granulocyte colony-stimulating factor applied during and after chemotherapy in patients with poor risk myelodysplastic syndromes: a report from the HOVON Cooperative Group. Dutch-Belgian Hemato-Oncology Cooperative Group. Leukemia 13(8): 1207-1213, 1999

The dose response relation of tolbutamide and ro 6 4563 glibornuride in beagle dogs. Dubach, U C And A Bueckert (Ed ) Recent Hypoglycemic Sulfonylureas Mechanisms Of Action And Clinical Indications Symposium 333p Illus Hans Huber: Bern, Switzerland 64-68, 1971

PET-based compartmental modeling of (124)I-A33 antibody: quantitative characterization of patient-specific tumor targeting in colorectal cancer. European Journal of Nuclear Medicine and Molecular Imaging 42(11): 1700-1706, 2015

Radiation-induced lung damage: dose-time-fractionation considerations. RadioTherapy and Oncology 14(1): 55-69, 1989

Focal experimental injury leads to widespread gene expression and histologic changes in equine flexor tendons. Plos one 10(4): E0122220, 2015

Linear diterpene with antimitotic activity from the brown alga Bifurcaria bifurcata. Phytochemistry (oxford). 34(6): 1585-1588, 1993

High-dose methotrexate in osteogenic sarcoma adjuvant chemotherapy and limb salvage results. Cancer Treatment Reports 65(Suppl. 1): 99, 1981

Hypothalamic-pituitary-thyroid system activity during lithium augmentation therapy in patients with unipolar major depression. Journal of Psychiatry and Neuroscience 28(3): 210-216, 2003

High-dose cyclophosphamide and dexamethasone in paraquat poisoning: a prospective study. Human and Experimental Toxicology 11(2): 129-134, 1992

High-dose pegylated interferon-α and ribavirin in nonresponder hepatitis C patients and relationship with IL-28B genotype (SYREN trial). Gastroenterology 141(1): 119-127, 2011

Lack of efficacy of a new antidepressant (bupropion) in the treatment of panic disorder with phobias. Journal of Clinical Psychopharmacology 3(1): 28-31, 1983