Sleep structure correlates of continuous positive airway pressure variations during application of an autotitrating continuous positive airway pressure machine in patients with obstructive sleep apnea syndrome



Sleep structure correlates of continuous positive airway pressure variations during application of an autotitrating continuous positive airway pressure machine in patients with obstructive sleep apnea syndrome



Chest 121(3): 759-767



Study objectives: To evaluate the relationship between sleep structure and continuous positive airway pressure (CPAP) delivered by an automatic CPAP (auto-CPAP) machine in patients with obstructive sleep apnea syndrome (OSAS). Design: Nocturnal polysomnography was performed during CPAP administration by an auto-CPAP machine (Autoset Clinical 1; ResMed; Sydney, Australia). Setting: Sleep-disorders center in a research institute. Patients: Fifteen subjects with newly diagnosed OSAS deserving home CPAP treatment. Measurements and results: During the night, in most cases, the lowest CPAP level was recorded during a prolonged nonrapid eye movement (NREM) sleep period uninterrupted by arousals, whereas the highest level during wake-sleep transitions or NREM sleep fragmented by arousals. In four subjects, rapid eye movement sleep was always associated with increasing CPAP. Sleep efficiency was negatively correlated with CPAP variability, evaluated as the SD of the mean nocturnal CPAP level averaged epoch by epoch (r = 0.63, p < 0.02). Eighty-eight percent of rapid CPAP augmentations (increases by at least 2 cm H2O in ltoreq 2 min) were observed during sleep-wake transitions or after arousals/awakenings (Ar/Aw); 63% of such Ar/Aw were not preceded by any detectable respiratory abnormality. Conclusions: CPAP levels and variations during auto-CPAP application may be mainly related to sleep continuity and efficiency. The recording of a highly variable pressure during auto-CPAP administration in an unattended environment must raise the question whether the patient's sleep quality was acceptable. A poor sleep quality during an autotitration night could lead to an undesirable overestimation of the CPAP level needed for use with fixed-level CPAP machines.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 011368364

Download citation: RISBibTeXText

PMID: 11888957

DOI: 10.1378/chest.121.3.759


Related references

Associations Between Sleep Quality, Sleep Architecture and Sleep Disordered Breathing and Memory After Continuous Positive Airway Pressure in Patients with Obstructive Sleep Apnea in the Apnea Positive Pressure Long-term Efficacy Study (APPLES). Sleep Science 11(4): 231-238, 2019

Validity Of Apnea-Hypopnea Index Determined By Autotitrating Continuous Positive Airway Pressure Device In Patients With Obstructive Sleep Apnea-Hypopnea Syndrome. Chest 132(4): 648-1, 2007

Practice parameters for the use of autotitrating continuous positive airway pressure devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome: An update for 2007. Sleep 31(1): 141-147, 2008

The current status of autotitrating continuous positive airway pressure systems in the management of obstructive sleep apnea. Canadian Respiratory Journal 12(5): 271-276, 2005

Effect of continuous positive airway pressure vs placebo continuous positive airway pressure on sleep quality in obstructive sleep apnea. Chest 116(6): 1545-1549, 1999

Compliance of obstructive sleep apnea patients in a randomized, double-blind trial Continuous positive airway pressure vs proportional positive airway pressure. Sleep 24(Abstract Suppl.): A256, 2001

Autotitration positive airway pressure therapy in patients with obstructive sleep apnea who are intolerant of fixed continuous positive airway pressure. Sleep and Breathing 12(3): 235-241, 2008

Frequency of upper airway symptoms before and during continuous positive airway pressure treatment in patients with obstructive sleep apnea syndrome. Respiration; International Review of Thoracic Diseases 80(6): 488-494, 2010

Should sleep laboratories have their own predictive formulas for continuous positive airway pressure for patients with obstructive sleep apnea syndrome?. Journal of the Chinese Medical Association 77(6): 283-289, 2014

Day-night variations of serum interleukin-6 in patients with severe obstructive sleep apnea syndrome before and after continuous positive airway pressure (CPAP). Chronobiology International 25(5): 827-834, 2008

The immediate effects of nasal continuous positive airway pressure treatment on sleep pattern in patients with obstructive sleep apnea syndrome. Electroencephalography & Clinical Neurophysiology 63(1): 10-17, 1986

Do personality traits in obstructive sleep apnea syndrome (OSAS) patients affect their purchase motivation of continuous positive airway pressure (CPAP) machine?. Sleep Medicine 16: S77-S78, 2015

Upper airway anatomical balance contributes to optimal continuous positive airway pressure for Japanese patients with obstructive sleep apnea syndrome. Journal of Clinical Sleep Medicine 10(2): 137-142, 2014

Application of continuous positive airway pressure through the nose in the treatment of obstructive sleep apnea syndrome. Annali Italiani di Medicina Interna 1(2): 131-140, 1986

Incidence and influencing factors of continuous positive airway pressure treatment-emergent central sleep apnea in the patients with obstructive sleep apnea syndrome at high altitude. Zhonghua Yi Xue Za Zhi 97(12): 915-919, 2017