+ Site Statistics
References:
54,258,434
Abstracts:
29,560,870
PMIDs:
28,072,757
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

The choice of reference cell in the analysis of kinetic data using BIAcore



The choice of reference cell in the analysis of kinetic data using BIAcore



Analytical Biochemistry 271(1): 70-80



An important step in the analysis of sensorgram data for BIAcore experiments is the subtraction of reference cell data to remove the effects of the bulk shift on the sensorgram of interest. It is shown that this step can introduce errors in the measured kinetic constants. This phenomenon is investigated both theoretically and with experimental data.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 011482725

Download citation: RISBibTeXText

PMID: 10361006

DOI: 10.1006/abio.1999.4129


Related references

Kinetic determinations of molecular interactions using Biacore--minimum data requirements for efficient experimental design. Journal of Molecular Recognition 18(4): 307-317, 2005

Kinetic, equilibrium, and thermodynamic analysis of macromolecular interactions with BIACORE. Methods in Enzymology 323: 325-340, 2000

Engineering scFvs and kinetic analysis of binding affinity on the BIAcore. Immunotechnology (Amsterdam) 2(4): 277-278, 1996

An analysis of transport resistances in the operation of BIAcore; implications for kinetic studies of biospecific interactions. Molecular Immunology 33(15): 1203-1214, 1996

Kinetic analysis of a high-affinity antibody/antigen interaction performed by multiple Biacore users. Analytical Biochemistry 352(2): 208-221, 2006

Analysis of the binding of the Fab fragment of monoclonal antibody NC10 to influenza virus N9 neuraminidase from tern and whale using the BIAcore biosensor: effect of immobilization level and flow rate on kinetic analysis. Analytical Biochemistry 273(1): 133-141, 1999

Capture molecules preconditioned for kinetic analysis of high-affinity antigen-antibody complex in Biacore A100. Analytical Biochemistry 424(2): 168-177, 2012

The choice of reference gene affects statistical efficiency in quantitative PCR data analysis. Biotechniques 55(4): 207-209, 2014

A Biacore biosensor method for detailed kinetic binding analysis of small molecule inhibitors of p38alpha mitogen-activated protein kinase. Analytical Biochemistry 325(1): 126-136, 2004

Kinetic modelling of oligomeric enzyme on the basis of phosphofructokinase i. general analysis of the experimental data and the choice of the adequate model. Molekulyarnaya Biologiya (Moscow) 21(3): 820-830, 1987

Affinity analysis of non-steady-state data obtained under mass transport limited conditions using BIAcore technology. Journal of Molecular Recognition 12(5): 285-292, 1999

A multiple-task gait analysis approach: kinematic, kinetic and EMG reference data for healthy young and adult subjects. Gait & Posture 33(1): 6-13, 2011

Influence of mass transfer and surface ligand heterogeneity on quantitative BIAcore binding data. Analysis of the interaction of NC10 Fab with an anti-idiotype Fab'. Journal of Molecular Recognition 10(3): 148-158, 1997