A chemometric study of active parameters and their interaction effects in a nebulized sheath-liquid electrospray interface for capillary electrophoresis-mass spectrometry



A chemometric study of active parameters and their interaction effects in a nebulized sheath-liquid electrospray interface for capillary electrophoresis-mass spectrometry



Electrophoresis 25(13): 2100-2107



A chemometrics approach has been used for evaluating the effect of four experimental parameters when coupling capillary electrophoresis (CE) to electrospray ionization-mass spectrometry (ESI-MS). Electrospray voltage, sheath-liquid flow rate, nebulizing gas flow rate, and spray needle position in respect to the MS orifice were varied according to a full factorial design. In addition to main effects, two interaction effects could be identified as significant when measuring the peak intensity of the analytes, from a sample mixture containing peptides and pharmaceuticals. The first interaction effects, between the nebulizing gas flow rate and the sheath-liquid flow rate, and the second interaction effect, between the nebulizing gas flow rate and the spray position, could further explain the impact that these variables have on the spray performance. The number of theoretical plates and the baseline noise were also measured. The sheath-liquid flow was found to significantly affect the separation efficiency, while the noise level mainly was controlled by the nebulizing gas flow. The same factorial design was also used for a CE capillary with lower internal diameter (ID) and the effects of the same variables were compared on those capillaries using equal injection volume for both capillaries. Similar trends were obtained in both capillaries but capillary ID was shown to be a significant variable when evaluating both capillaries in a single model. It was found that a capillary with 25 microm ID provided improved CE-MS performance over than corresponding 50 microm ID capillary. Enhanced sensitivity was obtained using the narrow-bore capillary, and at lower sheath-liquid flow rate the 25 microm ID capillary also gave rise to more efficient peaks.

(PDF emailed within 0-6 h: $19.90)

Accession: 011678314

Download citation: RISBibTeXText

PMID: 15237411

DOI: 10.1002/elps.200305937



Related references

A beveled tip sheath liquid interface for capillary electrophoresis-electrospray ionization-mass spectrometry. Electrophoresis 25(13): 2084-2089, 2004

In-spray supercharging of intact proteins by capillary electrophoresis-electrospray ionization-mass spectrometry using sheath liquid interface. Analytica Chimica Acta 813: 97-105, 2014

Liquid sheath effects on the separation of proteins in capillary electrophoresis/electrospray mass spectrometry. Analytical Chemistry 66(24): 4450-4458, 1994

Coupling of a large-size capillary column with an electrospray mass spectrometer. A reliable and sensitive sheath flow capillary electrophoresis-mass spectrometry interface. Journal of Chromatography. A 1013(1-2): 9-18, 2003

Design, optimisation, and evaluation of a sheath flow interface for automated capillary electrophoresis-electrospray-mass spectrometry. Electrophoresis 26(7-8): 1366-1375, 2005

Analysis of triazines by capillary electrochromatography/electrospray ionization-mass spectrometry using a low-flow sheath liquid interface. Electrophoresis 27(21): 4303-4311, 2006

Bottom-up proteome analysis of E. coli using capillary zone electrophoresis-tandem mass spectrometry with an electrokinetic sheath-flow electrospray interface. Proteomics 13(17): 2546-2551, 2014

Evaluation of volatile eluents and electrolytes for high-performance liquid chromatography-electrospray ionization mass spectrometry and capillary electrophoresis-electrospray ionization mass spectrometry of proteins. II. Capillary electrophoresis. Journal of Chromatography A 849(1): 175-189, July 16, 1999

Design and applications of a self-aligning liquid junction-electrospray interface for capillary electrophoresis-mass spectrometry. Journal Of Chromatography B Biomedical Applications. 685(2): 335-342, 1996

Analyte transport in liquid junction nano-electrospray interface between capillary electrophoresis and mass spectrometry. Electrophoresis 31(5): 879-885, 2010

Development of a poly(dimethylsiloxane) interface for on-line capillary column liquid chromatography-capillary electrophoresis coupled to sheathless electrospray ionization time-of-flight mass spectrometry. Analytical Chemistry 75(20): 5461-5467, 2004

Sheath liquid effects in capillary high-performance liquid chromatography-electrospray mass spectrometry of oligonucleotides. Journal of Chromatography A 870(1-2): 413-424, Feb 18, 2000

The development of a sheathless capillary electrophoresis electrospray ionization-mass spectrometry interface based on thin conducting liquid film. Journal of Chromatography. A 1267: 131-137, 2013

Capillary electrophoresis coupled to electrospray mass spectrometry through a coaxial sheath flow interface and semi-permanent phospholipid coating for the determination of oligosaccharides labeled with 1-aminopyrene-3,6,8-trisulfonic acid. Electrophoresis 33(4): 607-613, 2012

Simultaneous analysis of cocaine and its metabolites in urine by capillary electrophoresis-electrospray mass spectrometry using a pressurized liquid junction nanoflow interface. Electrophoresis 33(4): 653-660, 2012