A sheath-flow nanospray interface for capillary electrophoresis/mass spectrometry



A sheath-flow nanospray interface for capillary electrophoresis/mass spectrometry



Rapid Communications in Mass Spectrometry 19(2): 187-192



We have developed a novel sheath-flow interface for low-flow electrospray ionization mass spectrometry (ESI-MS) and capillary electrophoresis/electrospray mass spectrometry (CE/ESI-MS). The interface is composed of two capillaries. One is a tapered fused-silica ESI emitter suitable for microliter and nanoliter flow rate electrospray and the other is a tail-end gold-coated CE separation column that is inserted into the emitter. A sheath liquid is supplied between the column and the emitter capillaries. The gold coating and the sheath liquid are used as the conducting media for ESI and the CE circuit. This novel design was initially evaluated by an infusion ESI-MS analysis of the most common antiretroviral dideoxynucleosides, followed by CE/MS coupling analysis of several antidepressant drugs. With infusion studies, the effects of the sheath liquid and the sample flow rates on detection sensitivity and signal stability were investigated. For an emitter with an internal diameter of 30 mum, the optimum flow rates for the sheath and the sample were 200 and 300 nL/min, respectively. The main improvement of this approach in comparison with conventional sheath liquid approaches using an ionspray interface is the gain in sensitivity. Sensitivities were three times better for dideoxynucleosides analyzed by infusion and 12 times higher for antidepressant drugs analyzed by CEMS with this interface compared with ionspray. The emitter is durable, disposable, and simple to fabricate. Copyright Copyright 2004 John Wiley & Sons, Ltd.

(PDF emailed within 0-6 h: $19.90)

Accession: 011708650

Download citation: RISBibTeXText

PMID: 15593250

DOI: 10.1002/rcm.1769



Related references

Stable, reproducible, and automated capillary zone electrophoresis-tandem mass spectrometry system with an electrokinetically pumped sheath-flow nanospray interface. Analytica Chimica Acta 810: 94-98, 2014

Third-generation electrokinetically pumped sheath-flow nanospray interface with improved stability and sensitivity for automated capillary zone electrophoresis-mass spectrometry analysis of complex proteome digests. Journal of Proteome Research 14(5): 2312-2321, 2016

Coupling of a large-size capillary column with an electrospray mass spectrometer. A reliable and sensitive sheath flow capillary electrophoresis-mass spectrometry interface. Journal of Chromatography. A 1013(1-2): 9-18, 2003

A novel nanospray capillary zone electrophoresis/mass spectrometry interface. Rapid Communications in Mass Spectrometry 13(1): 67-72, 1999

Capillary zone electrophoresis for analysis of complex proteomes using an electrokinetically pumped sheath flow nanospray interface. Proteomics 14(4-5): 622-628, 2014

Simplified capillary electrophoresis nanospray sheath-flow interface for high efficiency and sensitive peptide analysis. Rapid Communications in Mass Spectrometry 24(17): 2554-2560, 2010

Hydrogen/deuterium exchange using a coaxial sheath-flow interface for capillary electrophoresis/mass spectrometry. Rapid Communications in Mass Spectrometry 14(9): 808-817, 2000

Capillary electrophoresis/mass spectrometry determination of inorganic ions using an ion spray-sheath flow interface. Electrophoresis. 14(5-6): 531-539, 1993

Design, optimisation, and evaluation of a sheath flow interface for automated capillary electrophoresis-electrospray-mass spectrometry. Electrophoresis 26(7-8): 1366-1375, 2005

Microelectrospray interface with coaxial sheath flow for high-resolution capillary electrophoresis/mass spectrometry separation. Rapid Communications in Mass Spectrometry 21(22): 3579-3584, 2007

Differential detection of Rhizoma coptidis by capillary electrophoresis electrospray ionization mass spectrometry with a nanospray interface. Electrophoresis 35(21-22): 3258-3263, 2015

Interface-free capillary electrophoresis-mass spectrometry system with nanospray ionization-Analysis of dexrazoxane in blood plasma. Journal of Chromatography. A 1466: 173-179, 2016

Bottom-up proteome analysis of E. coli using capillary zone electrophoresis-tandem mass spectrometry with an electrokinetic sheath-flow electrospray interface. Proteomics 13(17): 2546-2551, 2014

High speed capillary zone electrophoresis-mass spectrometry via an electrokinetically pumped sheath flow interface for rapid analysis of amino acids and a protein digest. Journal of Chromatography. B, Analytical Technologies in the Biomedical and Life Sciences 991: 53-58, 2016

Capillary electrophoresis coupled to electrospray mass spectrometry through a coaxial sheath flow interface and semi-permanent phospholipid coating for the determination of oligosaccharides labeled with 1-aminopyrene-3,6,8-trisulfonic acid. Electrophoresis 33(4): 607-613, 2012