Assessment of the unilateral pulmonary function by means of electrical impedance tomography using a reduced electrode set



Assessment of the unilateral pulmonary function by means of electrical impedance tomography using a reduced electrode set



Physiological Measurement 25(4): 803-813



The usefulness of electrical impedance tomography (EIT) to assess ventilation-related phenomena in the thorax has already been demonstrated, especially in controlled environments. We focus on our developments in the assessment of the unilateral pulmonary function (UPF) in real clinical environments. The impact of the reduction of the number of electrodes used is analysed theoretically and experimentally with different approaches. Sixteen-electrode EIT measurements were performed on a group of lung cancer patients (19 M, 2 F, ages 25-77 years). Results are compared with those obtained from ventilation scintigraphy. Eight-electrode measurements were synthesized from the 16-electrode ones. The Bland and Altman analysis indicates an agreement of about +/- 1 percent points in the estimation of UPF. On five of these patients real 8-electrode measurements were performed, obtaining differences from 0.2 percent to 6 percent points. It is concluded that reducing the number of electrodes does not adversely affect the assessment of UPF, but there is a reproducibility issue affecting all the techniques which needs further study.

(PDF emailed within 0-6 h: $19.90)

Accession: 011784512

Download citation: RISBibTeXText

PMID: 15382822

DOI: 10.1088/0967-3334/25/4/002



Related references

Use of electrical impedance tomography (EIT) for the assessment of unilateral pulmonary function. Physiological Measurement 23(1): 211-220, 2002

Assessment of the pulmonary volume pulse in idiopathic pulmonary arterial hypertension by means of electrical impedance tomography. Respiration; International Review of Thoracic Diseases 73(5): 597-602, 2005

Assessment of pulmonary edema in acute respiratory failure by means of electrical impedance tomography. European Respiratory Journal Supplement 10(25): 141S, Sept, 1997

Data recovery from reduced electrode connection in electrical impedance tomography. Medical Engineering & Physics. 18(6): 519-522, 1996

Improvement of cardiac imaging in electrical impedance tomography by means of a new electrode configuration. Physiological Measurement 17(3): 179-188, 1996

The grouped node technique as a means of handling large electrode surfaces in electrical impedance tomography. Physiological Measurement 16(3 Suppl A): A219-A226, 1995

Cardiac-related impedance changes obtained by electrical impedance tomography: an acceptable parameter for assessment of pulmonary perfusion?. Critical Care 15(3): 430-430, 2012

Pulmonary perfusion measured by means of electrical impedance tomography. Physiological Measurement 19(2): 263-273, 1998

Unilateral empyema impacts the assessment of regional lung ventilation by electrical impedance tomography. Physiological Measurement 35(6): 975-983, 2015

Pulmonary vascular damage in emphysema measured by means of electrical impedance tomography. European Respiratory Journal Supplement 9(23): 395S, 1996

An electrode addressing protocol for imaging brain function with electrical impedance tomography using a 16-channel semi-parallel system. Physiological Measurement 30(6): S85-101, 2009

Assessment of regional lung ventilation by electrical impedance tomography in a patient with unilateral bronchial stenosis and a history of tuberculosis. Jornal Brasileiro de Pneumologia 39(6): 742-746, 2014

Factors affecting electrode-gel-skin interface impedance in electrical impedance tomography. Medical & Biological Engineering & Computing 34(6): 397-408, 1996

Active electrode IC for EEG and electrical impedance tomography with continuous monitoring of contact impedance. IEEE Transactions on Biomedical Circuits and Systems 9(1): 21-33, 2015