+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Atrial fibrillation in patients with a dual defibrillator: characteristics of spontaneous and induced episodes and effect of ventricular tachyarrhythmia induction



Atrial fibrillation in patients with a dual defibrillator: characteristics of spontaneous and induced episodes and effect of ventricular tachyarrhythmia induction



Journal of Cardiovascular Electrophysiology 16(9): 974-980



The pattern of FF intervals during atrial fibrillation (AF) has been analyzed in induced and spontaneous AF episodes, after the induction of ventricular fibrillation (VF) and after atrial shock, in order to suggest practical considerations for AF management in patients implanted with antitachycardia devices. In 13 patients implanted with a dual-chamber defibrillator, FF intervals were analyzed during two separate induced AF episodes, before and after VF induction over AF, as well as during spontaneous AF episodes and after unsuccessful atrial shocks. The following parameters were considered: mean atrial cycle length (CL), atrial CL stability, and standard deviation of the atrial cycle. The AF pattern had comparable characteristics considering two separate inductions of AF, as well as spontaneous AF episodes. Ventricular tachyarrhythmia induction resulted in a shortening of atrial CL (P < 0.02) and in a less organized AF pattern (P < 0.005). Changes in the FF interval after ineffective shock therapy showed a shortening of AF cycles after shocks with energies far below the defibrillation threshold. (a) The AF pattern is reproducible in separate inductions of sustained AF and in spontaneous episodes, (b) dynamic changes involving a shortening of the AF cycle and an evolution to a less homogeneous pattern occur after VF induction, revealing a complex interplay between AF and VF, and (c) FF interval analysis after ineffective shock delivery may allow the relationship between delivered shock energy and effective defibrillation energy to be estimated, thereby providing practical suggestions for step-up protocols in atrial cardioversion.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 011789954

Download citation: RISBibTeXText

PMID: 16174019

DOI: 10.1111/j.1540-8167.2005.50009.x


Related references

The impact of atrial prevention and termination therapies on atrial tachyarrhythmia burden in patients receiving a dual-chamber defibrillator for ventricular arrhythmias. Journal of Interventional Cardiac Electrophysiology 10(2): 103-110, 2004

Rate characteristics and circadian variation of atrial tachyarrhythmia recurrences First lessons from patients with a dual-chamber defibrillator with atrial tiered therapies. European Heart Journal. 20(abstr. Suppl.): 451,., 1999

Atrial tachyarrhythmia induction in patients with wolff parkinson white with and without spontaneous atrial fibrillation. Giornale Italiano di Cardiologia 20(2): 109-113, 1990

Induction of atrial tachyarrhythmia in patients with Wolff-Parkinson-White syndrome with and without spontaneous atrial fibrillation. Giornale Italiano di Cardiologia 20(2): 109-113, 1990

Induction of ventricular fibrillation rather than ventricular tachycardia predicts tachyarrhythmia recurrences in patients with idiopathic dilated cardiomyopathy and implantable cardioverter defibrillator for secondary prophylaxis. Europace 11(3): 289-296, 2009

Reduction of ventricular tachyarrhythmia by treatment of atrial fibrillation in ICD patients with dual-chamber implantable cardioverter/defibrillators capable of atrial therapy delivery: the REVERT-AF Study. Europace 9(7): 534-539, 2007

Differences in the characteristics of induced and spontaneous episodes of ventricular fibrillation. Europace 9(11): 1054-1058, 2007

The incidence of atrial tachyarrhythmia recurrences during long-term follow-up of patients with a dual-chamber defibrillator supports the use of atrial antitachycardia pacing therapies. European Heart Journal 21(Abstract Supplement): 469, August-September, 2000

Dual site right atrial pacing can improve the impact of standard dual chamber pacing on atrial and ventricular mechanical function in patients with symptomatic atrial fibrillation: further observations from the dual site atrial pacing for prevention of atrial fibrillation trial. Journal of Interventional Cardiac Electrophysiology 12(3): 177-187, 2005

Clinical efficacy of dual defibrillator in preventing and treating drug refractory atrial fibrillation in patients without ventricular tachyarrhythmias. European Heart Journal 22(Abstract Supplement): 562, September, 2001

Erroneous discharge from an implanted automatic defibrillator during supraventricular tachyarrhythmia induced ventricular fibrillation. American Journal of Cardiology 57(4): 343-344, 1986

Efficacy of a dual chamber defibrillator with atrial antitachycardia functions in treating spontaneous atrial tachyarrhythmias in patients with life-threatening ventricular tachyarrhythmias. European Heart Journal 23(18): 1471-1479, 2002

Incidence of spontaneous ventricular arrhythmias in defibrillator patients with atrial fibrillation but no history of ventricular arrhythmias. Circulation 102(18 Supplement): II 395, October 31, 2000

Mode of spontaneous onset of ventricular fibrillation in patients with idiopathic ventricular fibrillation detected by implantable cardioverter defibrillator therapy. Circulation 98(17 SUPPL ): I289, Oct 27, 1998

Atrial defibrillation with implanted atrial defibrillator in patients with spontaneous atrial fibrillation. Circulation 96(8 SUPPL ): I75, 10/21/97, 1997