Comparative efficiency of the multi-leaf collimator and variable-aperture collimator in intensity-modulated radiotherapy



Comparative efficiency of the multi-leaf collimator and variable-aperture collimator in intensity-modulated radiotherapy



Physics in Medicine and Biology 51(7): 1725-1736



The potential of the variable-aperture collimator (VAC) in intensity-modulated radiation therapy (IMRT) has been evaluated by comparing its performance with that of the multi-leaf collimator (MLC). This comparison used a decomposition algorithm to find the series of collimator segments that would treat a given intensity-modulated beam (IMB). Collimator performance was measured using both the number of segments required to complete the IMB and the monitor-unit efficiency of the treatment. The VAC was modelled with aperture sizes from 4 x 4 cm to 20 x 20 cm, and these apertures were allowed to be located anywhere within the IMB. To enable a direct comparison, a similar scanning MLC was modelled at the same range of aperture sizes. Using both collimators, decompositions were run on 10 x 10 and 20 x 20 random IMBs with integer bixel values ranging from 1 to 10. Clinical IMBs from lung, head and neck, and pelvic patients were taken from a Pinnacle treatment-planning system and tested in the same manner. It was found that for all treatment sites, a small, scanning MLC performs as well or better than an equivalent sized VAC in both number of segments and monitor-unit efficiency, and would be an efficient choice for centres looking for a simple collimator for IMRT.

(PDF emailed within 0-6 h: $19.90)

Accession: 011878816

Download citation: RISBibTeXText

PMID: 16552100

DOI: 10.1088/0031-9155/51/7/006



Related references

Direct aperture optimization for a variable aperture collimator for intensity-modulated radiation therapy. Physics in Medicine and Biology 49(5): N47-N55, 2004

Intensity-modulated radiation therapy using a variable-aperture collimator. Physics in Medicine and Biology 48(9): 1223-1238, 2003

SU-E-T-390: Monitorization of the Dynamic Multi-Leaf Collimator Performance Using Log Files - a Quality Assurance Tool for Intensity Modulated Radiotherapy. Medical Physics 39(6part16): 3794-3794, 2012

Development and verification of a time delivery model for prostate intensity modulated radiotherapy using a Siemens ® Artiste™ 160 Multi-leaf Collimator Linac. Australasian Physical & Engineering Sciences in Medicine 40(1): 51-56, 2017

A Variable Circular Collimator: A Time-efficient Alternative for a Multi-leaf Collimator in Robotic Radiosurgery?. International Journal of Radiation Oncology*biology*physics 75(3): S674-S675, 2009

The effect of gantry and collimator angles on leaf limited velocity and position in dynamic multileaf collimator intensity-modulated radiation therapy. Physics in Medicine and Biology 55(11): 3101-3113, 2010

Multi-leaf collimator constrained optimization of intensity modulated treatments. Official Gazette of the United States Patent & Trademark Office Patents 1246(5), May 29, 2001

Influence of multi-leaf collimator leaf transmission on head and neck intensity-modulated radiation therapy and volumetric-modulated arc therapy planning. Japanese Journal of Radiology, 2017

A technique for dynamic intensity-modulated radiation therapy of the breast using a multi-leaf collimator. International Journal of Radiation Oncology Biology Physics 36(1 SUPPL ): 221, 1996

Dosimetric effects of multileaf collimator leaf width on intensity-modulated radiotherapy for head and neck cancer. Medical Physics 41(2): 021712-021712, 2014

Technical and dosimetric considerations in multi-isocenter intensity modulated radiotherapy for nasopharyngeal carcinoma with small multileaf collimator. Medical Dosimetry 34(1): 9-15, 2009

Forward-planned dose compensation for intensity modulated radiotherapy of the breast and internal mammary nodes using multi leaves collimator sub-fields. European Journal of Cancer Supplements 4(2): 97-98, 2006

Dosimetric effect of multileaf collimator leaf width in intensity-modulated radiotherapy delivery techniques for small- and large-volume targets. Journal of Medical Physics 36(2): 72-77, 2011

Comparison of a micro-multileaf collimator with a 5-mm-leaf-width collimator for intracranial stereotactic radiotherapy. International Journal of Radiation Oncology, Biology, Physics 57(5): 1443-1449, 2003

Intensity-modulated radiation therapy for mesothelioma: impact of multileaf collimator leaf width and pencil beam size on planning quality and delivery efficiency. International Journal of Radiation Oncology, Biology, Physics 62(5): 1525-1534, 2005