Coupling of a reagentless electrochemical DNA biosensor with conducting polymer film and nanocomposite as matrices for the detection of the HIV DNA sequences



Coupling of a reagentless electrochemical DNA biosensor with conducting polymer film and nanocomposite as matrices for the detection of the HIV DNA sequences



Analytical Letters 39(3): 467-482



This paper describes a reagentless electrochemical DNA biosensor applied to the detection of human immunodeficiency virus (HIV) sequences based on electrochemical impedance spectroscopy (EIS). The novel DNA biosensor has been elaborated by means of an opposite-charged adsorption Au-Ag nanocomposite to a conductive polymer polypyrrole (PPy) modified platinum electrode (Pt) and self-assembly the mercapto oligonucleotide probes onto the surface of modified electrode via the nanocomposite.

(PDF emailed within 0-6 h: $19.90)

Accession: 011908072

Download citation: RISBibTeXText

DOI: 10.1080/00032710500536012



Related references

Electrochemical detection of malathion pesticide using acetylcholinesterase biosensor based on glassy carbon electrode modified with conducting polymer film. Environmental Science and Pollution Research International 23(12): 12343-12351, 2016

Electrochemical immunosensor for ultrasensitive detection of microcystin-LR based on graphene-gold nanocomposite/functional conducting polymer/gold nanoparticle/ionic liquid composite film with electrodeposition. Biosensors & Bioelectronics 44: 235-240, 2013

Direct, reagentless electrochemical detection of the BIR3 domain of X-linked inhibitor of apoptosis protein using a peptide-based conducting polymer sensor. Biosensors & Bioelectronics 61: 57-62, 2015

Label-free and reagentless electrochemical detection of microRNAs using a conducting polymer nanostructured by carbon nanotubes: application to prostate cancer biomarker miR-141. Biosensors & Bioelectronics 49: 164-169, 2014

The development of reagentless lactate biosensor based on a novel conducting polymer. Bioelectrochemistry 68(2): 218-226, 2006

The development of a reagentless lactate biosensor based on a novel conducting polymer. Bioelectrochemistry 68(2): 218-226, 2005

Electrochemical and optical properties of a conducting polymer and its use in a novel biosensor for the detection of cholesterol. Sensors and Actuators B: Chemical 212: 425-433, 2015

Electrochemical detection of peroxynitrite using a biosensor based on a conducting polymer-manganese ion complex. Analytical Chemistry 82(24): 10075-10082, 2011

Reagentless electrochemical biosensor based on the multi-wall carbon nanotubes and nanogold particles composite film. Frontiers in Bioscience 10: 521-529, 2005

Reagentless electrochemical biosensor based on the multi-wall carbon nanotubes and nanogold particles composite film. Frontiers in Bioscience 10: 521-529, 2004

Coupling of an indicator-free electrochemical DNA biosensor with polymerase chain reaction for the detection of DNA sequences related to the apolipoprotein E. Analytica Chimica Acta 469(1): 93-99, 26 September, 2002

A new interference-free lysine biosensor using a non-conducting polymer film. Biosensors & Bioelectronics 13(12): 1245-1250, 1999

A new interference-free lysine biosensor using a non-conducting polymer film. Biosensors & Bioelectronics 13(12): 1245-1250, Dec 1, 1998

An electrochemical biosensor for determination of hydrogen peroxide using nanocomposite of poly(methylene blue) and FAD hybrid film. Sensors and Actuators B: Chemical 157(1): 202-210, 2011

Graphene oxide doped conducting polymer nanocomposite film for electrode-tissue interface. Biomaterials 35(7): 2120-2129, 2014