Diagnostic conclusions from the EASI-derived 12-lead electrocardiogram as compared with the standard 12-lead electrocardiogram in children



Diagnostic conclusions from the EASI-derived 12-lead electrocardiogram as compared with the standard 12-lead electrocardiogram in children



American Heart Journal 151(5): 1059-1064



Fewer electrodes on more easily located places would facilitate electrocardiogram (ECG) recording. To investigate the possibility of simplifying ECG recording in children, we compared the diagnostic conclusions when interpreting standard versus EASI-derived 12-lead ECGs. Our hypothesis was that the variation of the interpretation of standard versus EASI-derived 12-lead ECGs was not greater than the intrareader variation of the interpretation of standard ECGs. The study included 221 children. The 2 lead systems were recorded simultaneously. Two experienced pediatric cardiologists interpreted the ECGs. First, the reader interpreted a set of 221 ECGs with randomly allocated standard and EASI-derived 12-lead ECGs. Next, the reader interpreted the complementary ECG set without having access to the first set. Finally, the reader reinterpreted the standard ECGs from 98 children. The variation of the interpretation of standard versus EASI-derived 12-lead ECGs was only slightly larger than the intrareader variation of the interpretation of standard ECGs. For most of the electrocardiographic diagnoses, the conclusions from EASI-derived 12-lead ECGs were similar to those from standard ECGs. These findings support the suggestion that the EASI lead system is a potential alternative to the standard ECG in children.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 011950234

Download citation: RISBibTeXText

PMID: 16644336

DOI: 10.1016/j.ahj.2005.05.027


Related references

Accuracy of the EASI 12-lead electrocardiogram compared to the standard 12-lead electrocardiogram for diagnosing multiple cardiac abnormalities. Journal of Electrocardiology 32 Suppl: 38-47, 1999

Is the EASI 12-lead electrocardiogram comparable to the standard 12-lead electrocardiogram for diagnosing cardiac rhythm and myocardial ischemia?. Circulation 100(18 Suppl. ): I 736, 1999

Detection of acute ischemia from the EASI-derived 12-lead electrocardiogram and from the 12-lead electrocardiogram acquired in clinical practice. Journal of Electrocardiology 40(2): 120-126, 2007

EASI-Derived vs standard 12-lead electrocardiogram for Selvester QRS score estimations of chronic myocardial infarct size, using cardiac magnetic resonance imaging as gold standard. Journal of Electrocardiology 42(2): 145-151, 2009

Assessment of QT-measurement accuracy using the 12-lead electrocardiogram derived from EASI leads. Journal of Electrocardiology 40(2): 172-179, 2007

Effects of electrode placement errors in the EASI-derived 12-lead electrocardiogram. Journal of Electrocardiology 43(6): 606-611, 2011

Diagnostic value of Q waves outside standard precordial lead points in left anterior myocardial infarction undetectable by standard 12-lead electrocardiogram. Journal of Electrocardiology 21(4): 313-319, 1988

Deriving the 12-lead electrocardiogram from four (EASI) electrodes. Journal of Electrocardiology 21 Suppl: S182-S187, 1988

Detection of ST-T abnormalities by portable electrocardiogram monitoring devicescomparison with standard 12-lead electrocardiogram. Journal of Electrocardiology 42(6): 612-613, 2009

Method of deriving standard 12-lead electrocardiogram and electrocardiogram monitoring apparatus. Official Gazette of the United States Patent & Trademark Office Patents 1281(2), 2004

Comparison of a Smartphone-Based Electrocardiogram Device with a Standard Six-Lead Electrocardiogram in the Atlantic Bottlenose Dolphin ( Tursiops Truncatus). Journal of Zoo and Wildlife Medicine 49(3): 689-695, 2018

Comparison of the five-electrode-derived EASI electrocardiogram to the Mason Likar electrocardiogram in the prehospital setting. American Journal of Cardiology 96(3): 453-456, 2005

Comparison of head-chest lead electrocardiogram and routine lead electrocardiogram in diagnosis of acute posterior wall myocardial infarction. Nan Fang Yi Ke Da Xue Xue Bao 28(6): 956-958, 2008

Studies on applications of electrocardiogram in horses. I. The lead method and electrocardiogram with special reference to configurations and measurements of waves in the limb lead. Japanese Jour Vet Res 3(1): 24-32, 1955

Comparison of P waves recorded on the standard electrocardiogram, the "Lewis lead," and "saline-filled central venous catheter"-based intracardiac electrocardiogram. American Journal of Cardiology 94(4): 474-478, 2004