EurekaMag.com logo
+ Site Statistics
References:
53,869,633
Abstracts:
29,686,251
+ Search Articles
+ Subscribe to Site Feeds
EurekaMag Most Shared ContentMost Shared
EurekaMag PDF Full Text ContentPDF Full Text
+ PDF Full Text
Request PDF Full TextRequest PDF Full Text
+ Follow Us
Follow on FacebookFollow on Facebook
Follow on TwitterFollow on Twitter
Follow on LinkedInFollow on LinkedIn

+ Translate

Long-term safety and efficacy of circumferential ablation with pulmonary vein isolation



Long-term safety and efficacy of circumferential ablation with pulmonary vein isolation



Journal of Cardiovascular Electrophysiology 17(10): 1080-1085



Background: Each of the two main approaches to catheter ablation of atrial fibrillation (AF, segmental and circumferential) is associated with moderate long-term efficacy.Objective: To report the long-term outcomes of a modified technique that combines circumferential ablation with pulmonary vein (PV) isolation, determined by a circular mapping catheter and to determine the relationship between complete PV isolation and long-term efficacy.Methods: The patient population was composed of 64 consecutive patients (47 men [73%]; age 59 +/- 11 years) with AF who underwent catheter ablation. AF was paroxysmal in 29 (45%) and nonparoxysmal in 35 (55%). Each patient was followed for a minimum of 12 months.Results: After a mean follow-up of 13 +/- 1 months, the long-term single-procedure success rate was 45% (n = 29) with an additional 4% (n = 3) of patients demonstrating improvement. With repeat procedures in 19 patients, the overall long-term success rate was 62% (n = 40) with 9% (n = 6) demonstrating improvement. All the patients who underwent repeat ablations had recovered PV conduction. Incomplete PV isolation was the only independent predictor of failure. A major complication occurred in four (6%) patients, including three patients with vascular complications and one with cardiac tamponade.Conclusion: Our results suggest that the long-term single-procedure efficacy of circumferential ablation with PV isolation in a cohort of patients with predominantly nonparoxysmal AF approaches 50%. Repeat procedures involving re-isolation of the PVs result in a significant improvement in outcomes. Complete electrical isolation of the PVs has a significant impact on the long-term efficacy of the procedure.

(PDF emailed within 0-6 h: $19.90)

Accession: 012273601

Download citation: RISBibTeXText

PMID: 16989649

DOI: 10.1111/j.1540-8167.2006.00569.x



Related references

Efficacy and safety of circumferential pulmonary vein isolation with the anterior pulmonary vein vestibule intensive ablation and upstream therapy for atrial fibrillation. Zhonghua Yi Xue Za Zhi 94(47): 3761-3762, 2015

A randomized controlled trial of the efficacy and safety of electroanatomic circumferential pulmonary vein ablation supplemented by ablation of complex fractionated atrial electrograms versus potential-guided pulmonary vein antrum isolation guided by intracardiac ultrasound. Circulation. Arrhythmia and Electrophysiology 2(5): 481-487, 2009

Efficacy and safety of circumferential pulmonary vein isolation using a novel cryothermal balloon ablation system. Journal of the American College of Cardiology 46(10): 1902-1912, 2005

High-power and short-duration ablation for pulmonary vein isolation: Safety, efficacy, and long-term durability. Journal of Cardiovascular Electrophysiology, 2018

Pulmonary Vein Isolation with the Multipolar nMARQ Ablation Catheter: Efficacy And Safety In Acute And Long-Term Follow Up. Journal of Atrial Fibrillation 9(6): 1600-1600, 2017

Long-term efficacy of delayed cure after circumferential pulmonary vein ablation of atrial fibrillation. Journal of Interventional Cardiac Electrophysiology 23(3): 183-188, 2008

Long-term follow-up of pure linear ablation for persistent atrial fibrillation without circumferential pulmonary vein isolation. Journal of Cardiovascular Electrophysiology 25(5): 471-476, 2015

Efficacy and safety of segmental pulmonary vein isolation and circumferential pulmonary vein isolation in patients with atrial fibrillation: a comparative study. Nan Fang Yi Ke Da Xue Xue Bao 29(1): 128-132, 2010

Efficacy and safety of novel epicardial circumferential left atrial ablation with pulmonary vein isolation in sustained atrial fibrillation. Heart and Vessels 30(5): 675-681, 2016

Safety and efficacy of circumferential pulmonary vein catheter ablation of atrial fibrillation. Heart Rhythm 2(1): 42-48, 2005

Acute efficacy, safety, and long-term clinical outcomes using the second-generation cryoballoon for pulmonary vein isolation in patients with a left common pulmonary vein: A multicenter study. Heart Rhythm 14(8): 1111-1118, 2017

Cooled-tip vs. 8 mm-tip catheter for circumferential pulmonary vein ablation: comparison of efficacy, safety, and lesion extension. Europace 10(8): 955-960, 2008

The efficacy of inducibility and circumferential ablation with pulmonary vein isolation in patients with paroxysmal atrial fibrillation. Journal of Cardiovascular Electrophysiology 18(6): 607-611, 2007

Circumferential pulmonary vein ablation with additional linear ablation results in an increased incidence of left atrial flutter compared with segmental pulmonary vein isolation as an initial approach to ablation of paroxysmal atrial fibrillation. Circulation. Arrhythmia and Electrophysiology 3(3): 243-248, 2010

Catheter ablation of persistent atrial fibrillation: anatomically based circumferential pulmonary vein ablation in combination with a potential-guided segmental approach to achieve complete pulmonary vein isolation. Journal of Interventional Cardiac Electrophysiology 30(1): 63-72, 2011