Multicenter USA Amplatzer patent ductus arteriosus occlusion device trial: initial and one-year results



Multicenter USA Amplatzer patent ductus arteriosus occlusion device trial: initial and one-year results



Journal of the American College of Cardiology 44(3): 513-519



OBJECTIVES We sought to review and report initial and one-year efficacy and safety results of the multicenter USA Amplatzer ductal occluder (ADO) device trial. BACKGROUND Transcatheter closure of a moderate to large patent ductus arteriosus (PDA) using conventional techniques is challenging. The ADO can close a PDA up to 12 mm in diameter. METHODS From September 1999 to June 2002, 484 patients were enrolled in 25 U.S. centers. Forty-five (9%) of 484 patients did not have ADO implantation, because the PDA was too small or because of elevated pulmonary resistance. The median age of the patients at catheterization was 1.8 years (range 0.2 to 70.7 years), and weight was 11 kg (range 4.5 to 164.5 kg). RESULTS The median PDA minimal diameter was 2.6 mm (range 0.9 to 11.2 mm); 76 (17%) of 439 were larger than 4.0 mm. Median pulmonary artery mean pressure was 20 mm Hg (range 7 to 80 mm Hg). The ADO was implanted successfully in 435 (99%) of 439 patients, with a median fluoroscopy time of 7.1 min (range 2.9 to 138.4 min). Angiographic demonstration of occlusion was seen in 329 (76%) of 435. This increased to 384 (89%) of 433 on post-catheterization day 1, with occlusion documented in 359 (99.7%) of 360 at one year. At the last evaluation in all patients at any time, PDA closure was documented in 428 (98%) of 435 patients. There have been two cases of partial left pulmonary artery occlusion after ADO implantation and no cases of significant aortic obstruction. CONCLUSIONS Moderate to large PDAs can be effectively and safely closed using the ADO device, with excellent initial and one-year results. This device should obviate the need for multiple coils or surgical intervention for these defects. Copyright 2004 by the American College of Cardiology Foundation.

(PDF emailed within 0-6 h: $19.90)

Accession: 012331167

Download citation: RISBibTeXText

PMID: 15358013

DOI: 10.1016/j.jacc.2004.03.074



Related references

Multicenter nit-occlud® PDA-R patent. Ductus arteriosus occlusion device trial: initial and six-month results. Catheterization and Cardiovascular Interventions 86(2): 258-263, 2016

Closure of the patent ductus arteriosus with the amplatzer PDA device: immediate results of the international clinical trial. Catheterization and Cardiovascular Interventions 51(1): 50-54, 2000

Transcatheter closure of patent ductus arteriosus using the Amplatzer Duct Occluder Results of phase I US multicenter clinical trial. Circulation 100(18 SUPPL ): I 804, Nov 2, 1999

Transcatheter closure of patent ductus arteriosus using the Amplatzer duct occluder in children: initial and one-year results. Archivos de Cardiologia de Mexico 79(2): 114-120, 2009

International/US multicenter trial of transcatheter closure of patent ductus arteriosus using the Amplatzer duct occluder Acute and mid-term results. Journal of the American College of Cardiology 33(2 SUPPL A): 527A, 1999

Multicenter USA Amplatzer PDA occlusion device trial Initial and mid-term results. Circulation 106(19 Supplement): II 485, November 5, 2002

Application of echocardiography in transcatheter closure of patent ductus arteriosus using Amplatzer occlusion device. Zhongguo Chaosheng Yixue Zazhi 17(5): 351-353, 2001

Percutaneous occlusion of the patent ductus arteriosus with the amplatzer device for atrial septal defects. Journal of Invasive Cardiology 15(7): 413-417, 2003

Transcatheter occlusion of the patent ductus arteriosus in infants: experimental testing of a new Amplatzer device. Catheterization and Cardiovascular Interventions 83(2): 250-255, 2014

Comparative study on closure of patent ductus arteriosus by surgery and by transcatheter Amplatzer device occlusion. Zhonghua Xinxueguanbing Zazhi 30(7): 387-389, July, 2002

Late embolization of Amplatzer patent ductus arteriosus occlusion device with thoracic aorta embedment. Annals of Thoracic Surgery 83(3): 1177-1179, 2007

Amplatzer Device closure of Atrial Septal Defects and Patent Ductus Arteriosus: Initial Experience. Medical Journal, Armed Forces India 59(3): 218-222, 2003

Transcatheter occlusion of patent ductus arteriosus using a new angled Amplatzer duct occluder: initial clinical experience. Catheterization and Cardiovascular Interventions 58(2): 261-267, 2003

Results of transvenous buttoned device occlusion of patent ductus arteriosus in adults. International Buttoned Device Trial Group. American Journal of Cardiology 82(6): 827-9, A10, 1998

Results of the phase I food and drug administration clinical trial of duct-occlud device occlusion of patent ductus arteriosus. Catheterization and Cardiovascular Interventions 52(1): 74-78, 2001