+ Site Statistics
References:
54,258,434
Abstracts:
29,560,870
PMIDs:
28,072,757
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

The effect of clothes on sphygmomanometric and oscillometric blood pressure measurement



The effect of clothes on sphygmomanometric and oscillometric blood pressure measurement



Blood Pressure 13(5): 279-282



We determined the effect of wearing clothes under the manometer's cuff on blood pressure in manual auscultatory sphygmomanometric and automatic oscillometric blood pressure measurement. Two hundred and one subjects were examined with the auscultatory sphygmomanometric and the automatic oscillometric method, each with and without sleeved arm in random order. The auscultatory readings were blinded for the subjects' state of clothing. Common shirts and sweaters (thinner than 2 mm) were used. Based on confidence intervals of the differences between sleeved and non-sleeved arm measurements and equivalence test, sleeves did not lead to statistically significant effects. Measurements with and without sleeve can be accepted equal within an a priori defined interval of equivalence of +/-4 mmHg. This study shows that measuring blood pressure with the manometer's cuff over the subject's sleeve does not differ significantly from non-sleeved arm measurements. This is true for a sample that includes normotensive as well as hypertensive persons with a wide age range. For clinical practice, the not significant mean differences of 0.5-1.1 mmHg are interpreted as not relevant. In this study with a statistical power to find a difference of 4 mmHg, blood pressure measurements were found to be equivalent with and without clothes thinner than 2 mm.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 012645441

Download citation: RISBibTeXText

PMID: 15545150

DOI: 10.1080/08037050410016465


Related references

Effect of clothing on sphygmomanometric and oscillometric blood pressure measurement in hypertensive subjects. Deutsche Medizinische Wochenschrift 133(24): 1288-1292, 2008

The effect of clothes on sphygmomanometric blood pressure measurement in hypertensive patients. Journal of Clinical Nursing 19(13-14): 1861-1864, 2011

Doppler ultrasonographic, oscillometric sphygmomanometric, and photoplethysmographic techniques for noninvasive blood pressure measurement in anesthetized cats. Journal of Veterinary Internal Medicine 9(6): 405-414, 1995

A comparison of sphygmomanometric and oscillometric methods of blood pressure measurements in adult in-patients. Nigerian Journal of Clinical Practice 8(2): 86-89, 2006

Automatic blood pressure measurement: the oscillometric waveform shape is a potential contributor to differences between oscillometric and auscultatory pressure measurements. Journal of Hypertension 26(1): 35-43, 2007

Rapid oscillometric blood pressure measurement compared to conventional oscillometric measurement. Blood Pressure Monitoring 6(3): 145-147, 2001

Effect of respiration on Korotkoff sounds and oscillometric cuff pressure pulses during blood pressure measurement. Medical and Biological Engineering and Computing 52(5): 467-473, 2015

The effect of sleeved arms on oscillometric blood pressure measurement. Journal of General Internal Medicine 8(6): 325-326, 1993

Effect of peripheral edema on oscillometric blood pressure measurement. Journal of Cardiovascular and Thoracic Research 6(4): 217-221, 2015

The effect of clothes on blood pressure measurement. Pakistan Journal of Medical Sciences 33(1): 205-209, 2017

Differences in blood pressure measurements obtained using an automatic oscillometric sphygmomanometer depending on clothes-wearing status. Korean Journal of Family Medicine 34(2): 145-151, 2013

Comparison of invasive blood pressure measurement in the aorta with indirect oscillometric blood pressure measurement at the wrist and forearm. Zeitschrift für Kardiologie 84(9): 675-685, 1995

A method for extracting respiratory frequency during blood pressure measurement, from oscillometric cuff pressure pulses and Korotkoff sounds recorded during the measurement. Conference Proceedings 2016: 4268-4271, 2017

Effect of the shapes of the oscillometric pulse amplitude envelopes and their characteristic ratios on the differences between auscultatory and oscillometric blood pressure measurements. Blood Pressure Monitoring 12(5): 297-305, 2007

Comparison of two species-specific oscillometric blood pressure monitors with direct blood pressure measurement in anesthetized cats. Journal of Veterinary Emergency and Critical Care 27(4): 409-418, 2017