Accurate and reproducible target navigation with the Stereotaxis Niobe (R) Magnetic Navigation System



Accurate and reproducible target navigation with the Stereotaxis Niobe (R) Magnetic Navigation System



Journal of Cardiovascular Electrophysiology 18(Suppl. 1): S26-S31



Accurate and Reproducible Target Navigation. Introduction: The Stereotaxis Niobe (R) Magnetic Navigation System (MNS, Stereotaxis, Inc., St. Louis, MO, USA) allows for remote-control navigation of magnetically enabled catheters and guidewires for clinical ablation and electrophysiology (EP) device placement using two permanent magnets located on opposite sides of the patient table. Our objective was to provide a clinical framework for expected navigational accuracy during a case by calibrating the system's reproducibility using a realistic heart phantom under various conditions.Methods and Results: We performed two sets of experiments to demonstrate the accuracy of magnetic catheters using the MNS. The first experiment calibrated deviations in the deflection of an EP catheter by the magnetic system from the expected angles using proprietary algorithms based on predicted geometry. We found that the magnetic fields produced catheter angulation movements within a mean of 4 degrees of biophysical predictions. The second experiment used the MNS to navigate these catheters to previously labeled target positions within a phantom heart model and estimated the actual displacement from desired target positions. We found that the accuracy for reaching the desired targets was 100%.Conclusions: Remote navigation of magnetically enabled EP catheters using the MNS accurately and reproducibly navigates to target sites in a heart phantom. This may enable more complex, successful, and time-efficient procedures in the cardiac catheterization laboratory.

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 012941016

Download citation: RISBibTeXText


Related references

Use of the Stereotaxis Niobe magnetic navigation system for percutaneous coronary intervention: results from 350 consecutive patients. Catheterization and Cardiovascular Interventions 71(4): 510-516, 2008

Stereotaxis Niobe magnetic navigation system for endocardial catheter ablation and gastrointestinal capsule endoscopy. Expert Review of Medical Devices 6(5): 487-498, 2009

Successful ablation of focal left atrial tachycardia using Stereotaxis Niobe remote magnetic navigation system. Europace 10(3): 280-283, 2008

Remote catheter ablation using the new magnetic navigation system niobe. Journal of the American College of Cardiology 43(5 Supplement A): 149A, March 3, 2004

The new Niobe magnetic navigation system Early experiences in invasive cardiac interventions. Circulation 108(17 Supplement): IV-587, October 28, 2003

Use of the novel magnetic navigation system Niobe in percutaneous coronary interventions; the Hamburg experience. Eurointervention 1(3): 336-339, 2005

Modulation of the slow pathway in the presence of a persistent left superior caval vein using the novel magnetic navigation system Niobe. Europace 6(1): 10-14, 2003

An iterative method for the accurate determination of airborne gravity horizontal components using strapdown inertial navigation system/global navigation satellite system. Geophysics 80(6): G119-G129, 2015

Guidewire navigation in coronary artery stenoses using a novel magnetic navigation system: first clinical experience. Catheterization and Cardiovascular Interventions 67(3): 356-363, 2006

Feasibility and safety of guidewire navigation using a magnetic navigation system in coronary artery stenoses. Eurointervention 1(3): 329-335, 2005

Comparison of magnetic navigation system and conventional method in catheter ablation of atrial fibrillation: is magnetic navigation system is more effective and safer than conventional method?. Korean Circulation Journal 41(5): 248-252, 2011

Imageless navigation for insertion of the acetabular component in total hip arthroplasty: is it as accurate as CT-based navigation?. Journal of Bone and Joint Surgery. British Volume 88(2): 163-167, 2006

Combined use of TandemHeart percutaneous ventricular assist device and Stereotaxis magnetic navigation during cardiac ablation procedure. Heartrhythm Case Reports 2(1): 14-16, 2015

Magnetic navigation and catheter ablation of right atrial ectopic tachycardia in the presence of a hemi-azygos continuation: a magnetic navigation case using 3D electroanatomical mapping. Journal of Cardiovascular Electrophysiology 20(1): 99-102, 2008