+ Site Statistics
References:
52,654,530
Abstracts:
29,560,856
PMIDs:
28,072,755
+ Search Articles
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ PDF Full Text
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn

+ Translate
+ Recently Requested

Application of an in-line imprinted polymer column in a potentiometric flow-injection chemical sensor to the determination of the carbamate pesticide carbaryl in complex biological matrices



Application of an in-line imprinted polymer column in a potentiometric flow-injection chemical sensor to the determination of the carbamate pesticide carbaryl in complex biological matrices



Analytical and Bioanalytical Chemistry 387(1): 351-357



A flow-injection biosensor-like system based on a nonenzymatic approach has been developed to determine the carbamate pesticide carbaryl in complex biological samples without lengthy and expensive extraction steps. Molecularly imprinted polymeric beads were used to immobilize carbaryl from biological samples. pH variation permitted the elution of carbaryl from the binding cavity to the flow cell. A pH electrode was used to detect changes in the charge of carbaryl in the sample solution resulting from the protonation and deprotonation of the molecule over different pH ranges. At pH 2.0, the secondary amine group is protonated, giving a (+1) charge to the carbaryl molecule. At pH 8.0, the ionized carbaryl loses a proton to become neutral, changing the local pH of the flow cell. The pH change at the flow cell generated by the deprotonation of carbaryl ion in alkaline medium was used to determine the carbaryl concentration. Parameters influencing the performance of the system were optimized for use in the detection procedure. The validated biosensor-like system had a carbaryl detection limit of 10.0 microg/mL and a response that was linear (r2>0.98) over the concentration range of 10.0-00 microg/mL.

(PDF emailed within 0-6 h: $19.90)

Accession: 012945681

Download citation: RISBibTeXText

PMID: 17103148

DOI: 10.1007/s00216-006-0898-z


Related references

Use of an on-line imprinted polymer pre-column, for the liquid chromatographic-UV absorbance determination of carbaryl and its metabolite in complex matrices. Journal of Chromatography. A 1125(1): 104-111, 2006

Molecularly imprinted polymer based potentiometric sensor for the determination of hydroxyzine in tablets and biological fluids. Analytica Chimica Acta 612(1): 65-74, 2008

Design and fabrication of molecularly imprinted polymer-based potentiometric sensor from the surface modified multiwalled carbon nanotube for the determination of lindane (γ-hexachlorocyclohexane), an organochlorine pesticide. Biosensors & Bioelectronics 64: 586-593, 2015

Application of a metal ion-imprinted polymer based on salen-Cu complex to flow injection preconcentration and FAAS determination of copper. Talanta 76(1): 96-101, 2008

Determination of hydralazine with flow injection chemiluminescence sensor using molecularly imprinted polymer as recognition element. Journal of Pharmaceutical and Biomedical Analysis 41(3): 694-700, 2006

Flow-injection chemiluminescence sensor for determination of isoniazid in urine sample based on molecularly imprinted polymer. Spectrochimica Acta. Part A, Molecular and Biomolecular Spectroscopy 66(2): 341-346, 2006

Potentiometric sensor for determination of neutral bisphenol A using a molecularly imprinted polymer as a receptor. Analytical and Bioanalytical Chemistry 405(14): 4931-4936, 2013

Designing of molecularly imprinted polymer-based potentiometric sensor for the determination of heparin. Analytical Biochemistry 434(2): 242-246, 2013

Flow-injection chemiluminescence determination of trace copper on-line separation and enrichment by ion imprinted polymer. Guang Pu Xue Yu Guang Pu Fen Xi 31(6): 1472-1475, 2011

A biomimetic potentiometric sensor based on molecularly imprinted polymer for the determination of memantine in tablets. Drug Testing and Analysis 5(6): 461-467, 2013

The application of molecularly imprinted polymer sensor in pesticide detection. Nongyaoxue Xuebao 8(1): 8-13, 2006

On-line molecular imprinted solid-phase extraction flow-injection fluorescence sensor for determination of florfenicol in animal tissues. Journal of Pharmaceutical and Biomedical Analysis 52(4): 615-619, 2010

Preparation of nano-sized Pb2+ imprinted polymer and its application as the chemical interface of an electrochemical sensor for toxic lead determination in different real samples. Journal of Hazardous Materials 190(1-3): 451-459, 2011

Molecularly imprinted polymer-based potentiometric sensor for degradation product of chemical warfare agents. Part I. Methylphosphonic acid. Talanta 71(5): 1976-1980, 2007

Preparation of a new Cd(II)-imprinted polymer and its application to determination of cadmium(II) via flow-injection-flame atomic absorption spectrometry. Talanta 80(3): 1305-1310, 2010