+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Comparison of a guaiac based and an immunochemical faecal occult blood test in screening for colorectal cancer in a general average risk population



Comparison of a guaiac based and an immunochemical faecal occult blood test in screening for colorectal cancer in a general average risk population



Gut 56(2): 210-214



The guaiac faecal occult blood test (G-FOBT) is recommended as a screening test for colorectal cancer but its low sensitivity has prevented its use throughout the world. We compared the performances of the reference G-FOBT (non-rehydrated Hemoccult II test) and the immunochemical faecal occult blood test (I-FOBT) using different positivity cut-off values in an average risk population sample of 10,673 patients who completed the two tests. Patients with at least one test positive were asked to undergo colonoscopy. Using the usual cut-off point of 20 ng/ml haemoglobin, the gain in sensitivity associated with the use of I-FOBT (50% increase for cancer and 256% increase for high risk adenoma) was balanced by a decrease in specificity. The number of extra false positive results associated with the detection of one extra advanced neoplasia (cancer or high risk adenoma) was 2.17 (95% confidence interval 1.65-2.85). With a threshold of 50 ng/ml, I-FOBT detected more than twice as many advanced neoplasias as the G-FOBT (ratio of sensitivity = 2.33) without any loss in specificity (ratio of false positive rate = 0.99). With a threshold of 75 ng/ml, associated with a similar positivity rate to G-FOBT (2.4%), the use of I-FOBT allowed a gain in sensitivity of 90% and a decrease in the false positive rate of 33% for advanced neoplasia. Evidence in favour of the substitution of G-FOBT by I-FOBT is increasing, the gain being more important for high risk adenomas than for cancers. The automated reading technology allows choice of the positivity rate associated with an ideal balance between sensitivity and specificity.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 012955442

Download citation: RISBibTeXText

PMID: 16891354

DOI: 10.1136/gut.2006.101428


Related references

Screening for colorectal cancer: comparison of perceived test burden of guaiac-based faecal occult blood test, faecal immunochemical test and flexible sigmoidoscopy. European Journal of Cancer 46(11): 2059-2066, 2010

Prospective comparative evaluation of an office-based rapid immunological test with a Guaiac-based fecal occult blood test for colorectal cancer screening in general population with average-risk. Clinical Laboratory 54(9-10): 385-387, 2008

Cost analysis in a population based screening programme for colorectal cancer: comparison of immunochemical and guaiac faecal occult blood testing. Journal of Medical Screening 4(3): 142-146, 1997

A sensitive guaiac faecal occult blood test is less useful than an immunochemical test for colorectal cancer screening in a Chinese population. Alimentary Pharmacology & Therapeutics 18(9): 941-946, 2003

Immunochemical vs guaiac faecal occult blood tests in a population-based screening programme for colorectal cancer. British Journal of Cancer 74(1): 141-144, 1996

Performance of immunochemical faecal occult blood test in colorectal cancer screening in average-risk population according to positivity threshold and number of samples. International Journal of Cancer 125(5): 1127-1133, 2009

Evaluation and comparison of an immunochemical and a guaiac faecal occult blood screening test for colorectal neoplasia. European Journal of Cancer Prevention 4(6): 475-481, 1995

Population-based screening for colorectal cancer using an immunochemical faecal occult blood test: a comparison of two invitation strategies. Cancer Epidemiology 36(5): E317-E324, 2012

Evaluation of an immunochemical fecal occult blood test with automated reading in screening for colorectal cancer in a general average-risk population. International Journal of Cancer 115(3): 493-496, 2005

Comparison between a guaiac and three immunochemical faecal occult blood tests in screening for colorectal cancer. European Journal of Cancer 48(16): 2969-2976, 2012

Guaiac versus immunochemical tests: faecal occult blood test screening for colorectal cancer in a rural community. Australian and new Zealand Journal of Public Health 29(4): 358-364, 2005

Indirect comparison of two quantitative immunochemical faecal occult blood tests in a population with average colorectal cancer risk. Journal of Medical Screening 18(2): 76-81, 2011

Immunochemical testing of individuals positive for guaiac faecal occult blood test in a screening programme for colorectal cancer: an observational study. Lancet. Oncology 7(2): 127-131, 2006

Participation in four rounds of a French colorectal cancer screening programme with guaiac faecal occult blood test: a population-based open cohort study. Journal of Medical Screening 22(2): 76-82, 2015

Screening for colorectal cancer: randomised trial comparing guaiac-based and immunochemical faecal occult blood testing and flexible sigmoidoscopy. Gut 59(1): 62-68, 2010