The'Milko-Tester Automatic' for routine determination of fat in milk



The'Milko-Tester Automatic' for routine determination of fat in milk



Lait. 50: 495/496, 233-56



The 'Milko-tester Automatic' (MTA), in which improvements include homogenizing the milk after instead of before addition of the Versene/Triton X100 solution, was tested from Sept. 1968 to April 1969. For 70 samples of fresh milk from individual cows the SD of the difference between the fat % determined by MTA and by the Rose-Gottlieb method was +or-0.075, r being +0.996, and comparison with the Gerber method gave the same SD and r values.

(PDF emailed within 1 workday: $29.90)

Accession: 014780154

Download citation: RISBibTeXText


Related references

Large-scale application of the Milko-Tester-Automatic and Milko-Tester III for photometric determination of milk fat content. Anales del Instituto Nacional de Investigaciones Agrarias, Produccion Animal (3): 15-25, 1972

Studies on the fat determination of milk by means of Milko Tester Automatic and Milko Tester III. Milchwissenschaft 25 (5) 265-274, 1970

Studies on the fat determination of milk by means of automatic milko tester and milko tester iii. Milchwissenschaft: 265-274, 1970

Studies on the fat determination of milk by Milko-tester Automatic and Milko-tester III. Milchwissenschaft. 25: 5, 265-75, 1970

Automatic determination of fat in milk using the Milko-tester. Pishchevaya Promyshlennost' , Res ickanskii Mezhvedomstvennyi Nauchno tekhnicheskii Sbornik (18): 22-23, 1974

Testing of Milko-Tester Automatic F 3120 apparatus for determination of fat content of milk. Valt. Maitotalous. Kone Tarvikek, 73/74: 43-68, 1972

Trials on the automatic Milko-Tester machine for mass quantity determination of fats in milk. Lait 50 (495 496) 233-256, 1970

Trials of the automatic milko tester apparatus used for the serial determination of fatty matter in milk. Lait5-496: 254, 1970

Massive application of Milko-tester-automatic and Milkotester III equipment in photometric determination of fat content in milk. 1972

Experience of analytical testing with the Milko-Tester Automatic, Pro-Milk Automatic and IRMA. Mejeritidskrift for Finlands Svenskbygd 37(2): 4-10, 1975

Trials with the automatic Milko-Tester in serial estimation of milk fat. Lait. 50: 233-256, 1970

Investigations on the use of the Milko-tester for routine estimation of fat content in milk. J Dairy Res 34(1): 65-72, 1967

Biological factors responsible for variations in the precision of routine methods used for determining fat in milk (Milko-Tester, infra-red milk analyser and Gerber). Lait, 52: 515/516, 324-346, 1972

The suitability of the Milko-Tester (FPM Combi Automatic) for determining the fat and protein content of milk. S. Afr. J. Dairy Technol, 4: 2, 107-112, 1972