+ Site Statistics
References:
52,654,530
Abstracts:
29,560,856
PMIDs:
28,072,755
+ Search Articles
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ PDF Full Text
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Translate
+ Recently Requested

Distribution of trichloroethene in soil gas above contaminated ground water at Picatinny Arsenal, New Jersey



Distribution of trichloroethene in soil gas above contaminated ground water at Picatinny Arsenal, New Jersey



Water-Resources Investigations - U S




(PDF emailed within 1 workday: $29.90)

Accession: 018765170

Download citation: RISBibTeXText


Related references

Vapor distribution of trichloroethene and related compounds in soil gas above contaminated ground water at picatinny arsenal new jersey usa. Abstracts of Papers American Chemical Society 196: ENVR 154, 1988

Sampling unsaturated zone water for trichloroethene at picatinny arsenal new jersey. Journal of Environmental Quality 21(2): 264-271, 1992

Effect of soil moisture on the sorption of trichloroethene vapor to vadose-zone soil at Picatinny Arsenal, New Jersey. Environmental Science and Technology 24(5): 676-683, 1990

Comparison of four methods for sampling and analyzing unsaturated-zone water for trichloroethene at Picatinny Arsenal, New Jersey. Water-Resources Investigations - U S, 1991

Trichloroethene disequilibrium in the unsaturated zone at picatinny arsenal new jersey. Abstracts of Papers American Chemical Society 203(1-3): ENVR60, 1992

Simulation of ground-water flow at Picatinny Arsenal, New Jersey. Open-File Report - U S, 1991

Effect of air drying on solvent extraction of trichloroethylene-contaminated soil, Picatinny Arsenal, New Jersey. Water-Resources Investigations - U S, 1996

Surfactant-enhanced remediation of ground water at Picatinny Arsenal, New Jersey. Water-Resources Investigations - U S, 1996

Quantification of natural vapor fluxes of trichloroethene in the unsaturated zone at Picatinny Arsenal, New Jersey. Environmental Science & Technology 30(7): 2243-2250, 1996

Reconnaissance tools used to characterize ground-water contamination at Picatinny Arsenal, New Jersey. Abstracts with Programs - Geological Society of America 21(2): 64, 1989

Analysis of ground-water flowpaths near water-supply wells, Picatinny Arsenal, New Jersey. 1997

Assessment of contamination of ground water and surface water in the area of building 24, Picatinny Arsenal, New Jersey, 1986-87. 1990

Preliminary results of a study to simulate trichloroethylene movement in ground water at Picatinny Arsenal, New Jersey. Water-Resources Investigations - U S, 1989