+ Site Statistics
References:
54,258,434
Abstracts:
29,560,870
PMIDs:
28,072,757
+ Search Articles
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ PDF Full Text
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Translate
+ Recently Requested

3D magnetization prepared elliptical centric fast gradient echo imaging



3D magnetization prepared elliptical centric fast gradient echo imaging



Magnetic Resonance in Medicine 59(2): 434-439



3D magnetization-prepared fast gradient echo MR sequences, such as MP-RAGE and IR-SPGR, provide good spatial resolution and gray-white contrast. The efficiency and image quality of these techniques can be further improved with an interleaved, recessed elliptical centric view order. It is shown that this novel acquisition strategy, along with skipping the acquisition of views in k-space corners can provide images with higher signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), while reducing artifact level and scan time compared to standard MP-RAGE.

(PDF emailed within 0-6 h: $19.90)

Accession: 020635879

Download citation: RISBibTeXText

PMID: 18183604

DOI: 10.1002/mrm.21448


Related references

Magnetization prepared rapid gradient-echo (MP-RAGE) MR imaging of the liver: comparison with spin-echo imaging. Magnetic Resonance Imaging 9(4): 469-476, 1991

Gadolinium-enhanced three-dimensional magnetization-prepared rapid gradient-echo (3D MP-RAGE) imaging is superior to spin-echo imaging in delineating brain metastases. Acta Radiologica 49(10): 1167-1173, 2008

Performance of an elliptical centric view order for signal enhancement and motion artifact suppression in breath-hold three-dimensional gradient echo imaging. Magnetic Resonance in Medicine 38(5): 793-802, 1997

Magnetization-prepared cardiac imaging using gradient echo acquisition. Magnetic Resonance In Medicine. 30(2): 271-275, 1993

Magnetization transfer prepared gradient echo MRI for CEST imaging. Plos One 9(11): E112219-E112219, 2015

Improved efficiency in 2DFT magnetization-prepared rapid gradient echo imaging: application to abdominal imaging. Magnetic Resonance in Medicine 25(1): 195-203, 1992

Three-dimensional magnetization-prepared rapid gradient-echo imaging (3D MP RAGE). Magnetic Resonance in Medicine 15(1): 152-157, 1990

Rapid T1 estimation using tagged magnetization-prepared gradient-echo MR imaging. Magnetic Resonance in Medicine 26(2): 377-385, 1992

Tracking motion with tagged rapid gradient-echo magnetization-prepared MR imaging. Journal of Magnetic Resonance Imaging 2(2): 155-163, 1992

A comparison of magnetization prepared 3D gradient-echo (MP-RAGE) sequences for imaging of intracranial lesions. Magnetic Resonance Imaging 14(3): 329-335, 1996

Magnetization-prepared rapid gradient echo (MP-RAGE) magnetic resonance imaging of Morgagni's hernia. European Journal of Radiology 11(3): 196-199, 1990

Optimization of white-matter-nulled magnetization prepared rapid gradient echo (MP-RAGE) imaging. Magnetic Resonance in Medicine 73(5): 1786-1794, 2016

Parallel-transmission-enabled magnetization-prepared rapid gradient-echo T1-weighted imaging of the human brain at 7 T. Neuroimage 62(3): 2140-2150, 2012

Quantitative contrast ratio comparison between T1 (TSE at 1.5T, FLAIR at 3T), magnetization prepared rapid gradient echo and subtraction imaging at 1.5T and 3T. Quantitative Imaging in Medicine and Surgery 3(3): 141-146, 2013