+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Rapid detection of oleander poisoning by Digoxin III, a new Digoxin assay: impact on serum Digoxin measurement



Rapid detection of oleander poisoning by Digoxin III, a new Digoxin assay: impact on serum Digoxin measurement



American Journal of Clinical Pathology 129(4): 548-553



We studied the potential for detecting oleander with a new immunoassay (Digoxin III, Abbott Laboratories, Abbott Park, IL) by comparing results with those from the fluorescence polarization immunoassay (FPIA) and Digoxin II assay (Abbott). In aliquots of drug-free serum pools supplemented with pure oleandrin or oleander extract, we observed apparent digoxin values using all 3 immunoassays, but values obtained by the Digoxin III were higher than obtained by the other assays. We also observed significant apparent digoxin values in vivo in serum samples of mice 1 and 2 hours after feeding oleander extract. The average half-life of digoxin-like factors was 1.1 hours. In a serum pool (prepared from patients taking digoxin) supplemented with oleander extract, the observed digoxin values were falsely lowered when measured by the Digoxin II but falsely elevated when measured by the Digoxin III and FPIA. Monitoring free digoxin using the Digoxin III cannot eliminate this interference. Digibind neutralized digoxin-like factors of oleander extract; the effect can be monitored by observing a significant reduction in apparent free digoxin levels in the presence of Digibind as measured in protein-free ultrafiltrate using the Digoxin III. The Digoxin III is highly sensitive for measuring oleander.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 021636424

Download citation: RISBibTeXText

PMID: 18343781

DOI: 10.1309/cc6791dff20qpcx3


Related references

Bidirectional (positive/negative) interference of spironolactone, canrenone, and potassium canrenoate on serum digoxin measurement: elimination of interference by measuring free digoxin or using a chemiluminescent assay for digoxin. Journal of Clinical Laboratory Analysis 16(4): 172-177, 2002

Positive and negative interference of the Chinese medicine Chan Su in serum digoxin measurement. Elimination of interference by using a monoclonal chemiluminescent digoxin assay or monitoring free digoxin concentration. American Journal of Clinical Pathology 114(2): 174-179, 2000

Rapid detection of oleander poisoning by Dimension Vista digoxin assay (Flex Reagent Cartridge). Journal of Clinical Laboratory Analysis 25(2): 105-109, 2011

Cross reactivity of the EMIT digoxin assay with digoxin metabolites, and validation of the method for measurement of urinary digoxin. Clinical Chemistry 29(1): 175-177, 1983

Effect of endogenous digoxin-like immunoreactive factors on serum digoxin measurement by a new turbidimetric digoxin immunoassay. Clinical Chemistry 49(S6): A78, 2003

Effect of Chinese medicines Chan Su and Lu-Shen-Wan on serum digoxin measurement by Digoxin III, a new digoxin immunoassay. Therapeutic Drug Monitoring 30(1): 95-99, 2008

Effect of spironolactone, potassium canrenoate and their common metabolite canrenone on serum digoxin measurement by digoxin III, a new digoxin immunoassay. Therapeutic Drug Monitoring 30(6): 744-747, 2008

Effect of Asian and Siberian ginseng on serum digoxin measurement by five digoxin immunoassays. Significant variation in digoxin-like immunoreactivity among commercial ginsengs. American Journal of Clinical Pathology 119(2): 298-303, 2003

Interference of endogenous digoxin-like immunoreactive factors in serum digoxin measurement is minimized in a new turbidimetric digoxin immunoassay on ADVIA 1650 analyzer. Therapeutic Drug Monitoring 26(1): 85-89, 2004

Suppression of total digoxin concentrations by digoxin-like immunoreactive substances in the MEIA digoxin assay. Elimination of negative interference by monitoring free digoxin concentrations. American Journal of Clinical Pathology 111(3): 406-410, 1999

Rapid Detection of Oleander Poisoning Using Digoxin Immunoassays. Therapeutic Drug Monitoring 26(6): 658-663, 2004

Technicon digoxin assay a fully automated enzyme immunoassay for the detection of digoxin in human serum. Clinical Chemistry 36(6): 1103, 1990

Comparison of 3 digoxin assay methods in the detection of endogenous digoxin like substance in serum of low birth weight infants. Clinical Research 33(1): 114A, 1985

Effect of Asian ginseng, Siberian ginseng, and Indian ayurvedic medicine Ashwagandha on serum digoxin measurement by Digoxin III, a new digoxin immunoassay. Journal of Clinical Laboratory Analysis 22(4): 295-301, 2008

Rapid detection of oleander poisoning using digoxin immunoassays: comparison of five assays. Therapeutic Drug Monitoring 26(6): 658-663, 2004