EurekaMag.com logo
+ Site Statistics
References:
52,725,316
Abstracts:
28,411,598
+ Search Articles
+ Subscribe to Site Feeds
EurekaMag Most Shared ContentMost Shared
EurekaMag PDF Full Text ContentPDF Full Text
+ PDF Full Text
Request PDF Full TextRequest PDF Full Text
+ Follow Us
Follow on FacebookFollow on Facebook
Follow on TwitterFollow on Twitter
Follow on Google+Follow on Google+
Follow on LinkedInFollow on LinkedIn

+ Translate

Kinematic study for stability of total hip prosthesis






Korea University Medical Journal 14(3): 447-476

Kinematic study for stability of total hip prosthesis



Accession: 026874960



Related references

Malkani, A.L.; Rand, J.A.; Bryan, R.S.; Wallrichs, S.L., 1995: Total knee arthroplasty with the kinematic condylar prosthesis. A ten-year follow-up study. Of 168 consecutive knees (118 patients) that had been treated with an arthroplasty with use of a kinematic total condylar prosthesis that allowed retention of the posterior cruciate ligament, 119 knees (eighty-four patients) were available for rev...

Aglietti, P.; Mazzotti, G.N., 1981: Total knee prosthesis. Evolution of the principles and technique and initial results obtained with the total-condylar knee prosthesis "with posterior stability". The principles and details of the surgical technique for the insertion of total knee prostheses are presented, in particular the methods of dealing with the soft tissues, the correction of deformities, and the sequence and details of making the bo...

Kabo, J.M.; Yang, R.S.; Dorey, F.J.; Eckardt, J.J., 1997: In vivo rotational stability of the kinematic rotating hinge knee prosthesis. The in vivo rotary laxity and torsional stiffness of the knee joint were measured in 20 patients with wide intraarticular resection of the distal femoral tumor followed by reconstruction with a custom Kinematic rotating hinge endoprosthesis. The c...

Shaw, J.A.; Balcom, W.; Greer, R.B., 1989: Total knee arthroplasty using the kinematic rotating hinge prosthesis. Patients receiving a Kinematic Rotating Hinge total knee prosthesis with a 25-month minimum follow up were reviewed. A total of 46 patients and 54 knees were included in the study. A detailed clinical assessment was available on 38 knees. Twenty o...

Kraft, E., 1965: Experimental Study Of The Stability Of Total Lower Prosthesis Following Differentiated Impression Procedure. Deutsche Zahnarztliche Zeitschrift 20: 629-629

Sextro, G.S.; Berry, D.J.; Rand, J.A., 2001: Total knee arthroplasty using cruciate-retaining kinematic condylar prosthesis. The purpose of the current study was to evaluate the long-term results of the Kinematic I condylar prosthesis with retention of the posterior cruciate ligament. One hundred sixty-eight total knee arthroplasties in 118 patients (mean age, 65.2 year...

Stiehl, J.B.; Dennis, D.A.; Komistek, R.D.; Keblish, P.A., 1998: In vivo kinematic analysis of a mobile bearing total knee prosthesis. Ten normal subjects and 10 patients with a posterior cruciate retaining mobile bearing total knee replacement performed successive deep knee bends under fluoroscopy to determine tibiofemoral contact positions. At full extension the average initial...

Low, F.H.; Khoo, L.P.; Chua, C.K.; Lo, N.N., 2000: Kinematic analysis of total knee prosthesis designed for Asian population. In designing a total knee replacement (TKR) prosthesis catering for the Asian population, 62 sets of femur were harvested and analyzed. The morphometrical data obtained were found to be in good agreement with dimensions typical of the Asian knee a...

Wright, J.; Ewald, F.C.; Walker, P.S.; Thomas, W.H.; Poss, R.; Sledge, C.B., 1990: Total knee arthroplasty with the kinematic prosthesis. Results after five to nine years: a follow-up note. A review of the results of 192 kinematic total knee replacements five to nine years after the operation showed that the results were still satisfactory. At the time of the review, the ages of the patients ranged from twenty-two to eighty-seven yea...

Hanssen, A.D.; Rand, J.A., 1988: A comparison of primary and revision total knee arthroplasty using the kinematic stabilizer prosthesis. The first 121 arthroplasties (in 105 patients) in which the cemented kinematic-stabilizer total knee prosthesis was used for primary arthroplasty or surgical revision at the Mayo Clinic [USA] were reviewed. Sixty-six patients (seventy-nine arthrop...