+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Mucosal petechiometry: a reliable method for the measurement of capillary resistance



Mucosal petechiometry: a reliable method for the measurement of capillary resistance



British Journal of Oral Surgery 14(3): 230-239



The method of mucosal petechiometry, as described by Kozam (1968), was investigated and found to be a valid technique for investigating capillary resistance. Recommendations are made on the use of this technique as a research method.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 026999021

Download citation: RISBibTeXText

PMID: 265172

DOI: 10.1016/0007-117x(77)90030-0


Related references

ACTH and resistance of small blood vessels to trauma: use of mucosal petechiometry. British Journal of Oral Surgery 18(2): 95-99, 1980

Tu1102 A New Method for Constant Mucosal Contact and Reliable Measurement of Esophageal Mucosal Impedance. Gastroenterology 146(5): S-753, 2014

On the Control of Capillary Resistance by Anticoagulant Therapy; Measurement of Capillary Resistance by a Sensitive Method. Acta Medica Academiae Scientiarum Hungaricae 20: 295-300, 1964

Control of Capillary Resistance During Anticoagulant Therapy. (A Sensitive Method for the Measurement of Capillary Resistance). Orvosi Hetilap 105: 2172-2174, 1964

A more reliable measurement method for metal/graphene contact resistance. Nanotechnology 26(40): 405706, 2015

A new method for measurement of capillary resistance. Klinische Wochenschrift 31(31-32): 751-754, 1953

A comparison of template bleeding time with mucosal petechiometry as a measure of the platelet function defect induced by aspirin. British Journal of Oral & Maxillofacial Surgery 29(3): 173-175, 1991

Ultrasonographic measurement of the ligamentum flavum depth; is it a reliable method to distinguish true and false loss of resistance?. Korean Journal of Pain 25(2): 99, 2012

Contact angle measurement - a reliable supportive method for screening water-resistance of ultraviolet-protecting products in vivo. International Journal of Cosmetic Science 29(4): 283-291, 2007

Critical evaluation of data on the measurement of capillary resistance by the suction method. Bibliotheca Anatomica 9: 121-124, 1967

Resistance of capillary walls. A simple clinical method for its exact measurement. Munchener Med Wochenschr 76(41): 1717-1718, 1929

Capillary-Protective Action of 4-Methyl-6,7-(Bis-Beta-Diethylaminoethoxy)-Coumarin Hyrochloride in Parenteral and Oral Administration. Study of Bleeding time and Intensity and Petechiometry. Haematologica 48: 937-955, 1963

On the pathogenesis of icterus neonatorum; bilirubin determination and measurement of capillary resistance in the new born; experiments on treatment of jaundice and disordered capillary resistance with vitamin C, vitamin B complex and adrenal cortex hormone. Zeitschrift für Geburtshilfe und Gynakologie 138(3): 287-303, 1953

Simultaneous measurement of alpha-amylase and glucoamylase activities in sake rice koji by capillary electrophoresis of sodium dodecyl sulfate-protein complexes and activity measurement of glucoamylase by in-capillary enzyme reaction method. Electrophoresis 19(13): 2331-2337, 1998

Measurement of capillary refill time in term neonates is not a reliable indicator of cardiovascular status. Pediatric Research 53(4 Part 2): 419A, 2003