+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Peak and phasic changes of power utilization of a total artificial heart in response to after-load



Peak and phasic changes of power utilization of a total artificial heart in response to after-load



Transactions - American Society for Artificial Internal Organs 23: 512-518




Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 027121479

Download citation: RISBibTeXText

PMID: 910374

DOI: 10.1097/00002480-197700230-00136


Related references

Total artificial heart utilization in man. Transactions American Society for Artificial Internal Organs 28: 534-538, 1982

Total artificial heart (TAH) utilization in man. Transactions - American Society for Artificial Internal Organs 28: 534-538, 1982

Fifteen years single center experience with the total artificial heart Jarvik-7 A bridge to the new era of electrical total artificial heart. Journal of Heart & Lung Transplantation 21(1): 106, 2002

Normalization for peak VO2 increases the prognostic power to the ventilatory response to exercise in chronic heart failure. Circulation 106(19 Suppl.): II-646, 2002

Current state of total artificial heart therapy and introduction of the most important total artificial heart systems. Biomedizinische Technik. Biomedical Engineering 64(3): 247-250, 2019

The 50/50 cc Total Artificial Heart Trial: Extending the Benefits of the Total Artificial Heart to Underserved Populations. Seminars in Thoracic and Cardiovascular Surgery. Pediatric Cardiac Surgery Annual 20: 16-19, 2017

Age differences in high frequency phasic heart rate variability and performance response to increased executive function load in three executive function tasks. Frontiers in Psychology 5: 1470, 2014

Normalization for peak oxygen uptake increases the prognostic power of the ventilatory response to exercise in patients with chronic heart failure. American Heart Journal 146(3): 542-548, 2003

First North American 50 cc Total Artificial Heart Experience: Conversion from a 70 cc Total Artificial Heart. Asaio Journal 62(5): E43-E45, 2016

Expanding Applicability of Total Artificial Heart Therapy: The 50-cc SynCardia Total Artificial Heart. Annals of Thoracic Surgery 100(3): E55-E57, 2015

Total Artificial Heart Implantation Blood Pressure Management as Resolving Treatment for Massive Hemolysis following Total Artificial Heart Implantation. Heart Surgery Forum 19(5): E229, 2016

Auxiliary total artificial heart: A compact electromechanical artificial heart working simultaneously with the natural heart. Artificial Organs 23(9): 876-880, 1999

Dependence of peak dp dt and mean ejection rate on load and effect of inotropic agents on the relationship between peak dp dt and left ventricular development pressure assessed in the isolated working rat heart and cardiac muscles. International Journal of Cardiology 35(3): 333-341, 1992

Targeting of high peak respiratory exchange ratio is safe and enhances the prognostic power of peak oxygen uptake for heart failure patients. Circulation Journal 78(9): 2268-2275, 2014

Use of a total right heart bypass model for analyses of abnormal hemodynamics in total artificial heart animals, and the function and regulatory mechanisms of a natural heart. Asaio Transactions 35(3): 705-708, 1989