+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Trace zinc determination in acid media by differential pulse anodic stripping voltammetry at a hanging drop mercury electrode



Trace zinc determination in acid media by differential pulse anodic stripping voltammetry at a hanging drop mercury electrode



Analytical Chemistry 48(4): 759-761




Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 027780338

Download citation: RISBibTeXText

DOI: 10.1021/ac60368a034


Related references

Determination of Zn, Cd, Pb, Cu, Sb and Bi in milk by differential pulse anodic stripping voltammetry with a hanging mercury drop electrode following two independent mineralisation methods. Analusis 13(10): 471-473, 1985

Studies of pretreatments in the determination of Zn, Cd, Pb, Cu, Sb and Bi in suspended particulate matter and plankton by differential-pulse anodic-stripping voltammetry with a hanging mercury drop electrode. Talanta 29(8): 651-654, 1982

Direct determination of trace and sub trace metals in natural waters by differential pulse anodic stripping voltammetry use of long lasting sessile drop mercury electrodes compared to commercial hanging drop mercury electrodes kemula type. Analytical Letters 15(19): 1565-1584, 1982

Determination of trace amounts of bacitracin by differential pulse adsorptive stripping voltammetry at a hanging mercury drop electrode. Analytical Proceedings 28(1): 16-20, 1991

A rapid determination of trace amounts of bismuth in urine and blood using differential pulse anodic stripping voltammetry at the hanging mercury electrode. Analytical Letters 14(B15): 1209-1220, 1981

Direct and simultaneous determinations of Zn, Cd, Pb, Cu, Sb and Bi dissolved in sea water by differential pulse anodic stripping voltammetry with a hanging mercury drop electrode. Analytica Chimica Acta 106(1): 23-37, 1979

Implementation of a differential pulse anodic stripping voltammetry (DPASV) at a hanging mercury drop electrode (HMDE) procedure for the analysis of airborne heavy metals. Analytical Letters 34(13): 2349-2360, 2001

Simultaneous determination of Cd, Pb, Cu, Sb, Bi, Se, Zn, Mn, Ni, Co and Fe in water samples by differential pulse stripping voltammetry at a hanging mercury drop electrode. Fresenius' Journal of Analytical Chemistry 367(4): 378-383, 2000

Determination of naringin in grapefruit juice by cathodic stripping differential pulse voltammetry at the hanging mercury drop electrode. Analytica Chimica Acta. 360(1-3): 179-187, Ch 10, 1998

Determination of trace amounts of thallium in urine, using the mercury-film electrode and differential pulse anodic stripping voltammetry. Journal - Association of Official Analytical Chemists 57(6): 1366-1372, 1974

Low-level determination of silicon in steels by anodic stripping voltammetry on a hanging mercury drop electrode. Talanta 82(5): 1839-1844, 2010

Disturbance of a Film of Triton X-100 on the Hanging Mercury Drop Electrode during the Determination of Metal Ions by Anodic Stripping Voltammetry. Collection of Czechoslovak Chemical Communications 58(2): 291-294, 1993

Determination of ionic zinc cadmium and lead in sea water by differential pulse anodic stripping voltammetry at a slowly dropping mercury electrode. Annali di Chimica 68(3-4): 227-234, 1978

Determination of trace metals by anodic-stripping voltammetry with a new kind of mercury electrode: The long-lasting sessile-drop electrode. Talanta 28(11): 839-842, 1981

Differential pulse cathodic stripping voltammetry of the copper complexes of glycyl-L-histidyl-glycine at a hanging mercury drop electrode. Talanta 40(10): 1481-1488, 1993