+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

High inverse inspiratory expiratory ratio ventilation with low positive end expiratory pressure in respiratory distress syndrome



High inverse inspiratory expiratory ratio ventilation with low positive end expiratory pressure in respiratory distress syndrome



American Review Of Respiratory Disease Part 2: 275




Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 028427752

Download citation: RISBibTeXText


Related references

Effects of inverse ratio ventilation versus positive end-expiratory pressure on gas exchange and gastric intramucosal PCO(2) and pH under constant mean airway pressure in acute respiratory distress syndrome. Anesthesiology 95(5): 1182-1188, 2001

Effects of inverse inspiratory expiratory ratio and positive end expiratory pressure ventilation on pulmonary gas exchange mechanics and hemodynamics in dogs with hemorrhagic pulmonary edema. American Review of Respiratory Disease 117(4 Part 2): 373, 1978

Effects of combined inspiratory and expiratory positive pressure in assisted ventilation for critical respiratory distress syndrome. Pediatric Research 6(4): 410, 1972

Improved arterial oxygenation and CO2 elimination following changes from volume-generated PEEP ventilation with inspiratory/expiratory (I/E) ratio of 1:2 to pressure-generated ventilation with I/E ratio of 4:1 in patients with severe adult respiratory distress syndrome (ARDS). Advances in Experimental Medicine and Biology 248: 779-786, 1989

Expiratory flow limitation and intrinsic positive end-expiratory pressure at zero positive end-expiratory pressure in patients with adult respiratory distress syndrome. American Journal of Respiratory and Critical Care Medicine 161(5): 1590-1596, 2000

Inspiratory-to-expiratory ratio during ventilation for idiopathic respiratory distress syndrome. Pediatric Pulmonology 7(1): 2-7, 1989

Respiratory distress syndrome and its treatment with high positive end-expiratory pressure ventilation. International Surgery 67(3): 245-250, 1982

Long term treatment of 2 patients with respiratory insufficiency with intermittent positive pressure ventilation positive end expiratory pressure and high frequency positive pressure ventilation positive end expiratory pressure. Acta Anaesthesiologica Scandinavica Supplementum: 68, 1977

Reverse inspiratory time expiratory time ratio continuous positive airway pressure and conventional mechanical ventilation with positive end expiratory pressure is there a difference. Anesthesiology 51(3 Suppl.): S188, 1979

High-frequency pressure-control ventilation with high positive end-expiratory pressure in children with acute respiratory distress syndrome. Journal of Pediatrics 129(4): 566-573, 1996

Positive end-expiratory pressure titrated according to respiratory system mechanics or to ARDSNetwork table did not guarantee positive end-expiratory transpulmonary pressure in acute respiratory distress syndrome. Journal of Critical Care 48: 433-442, 2018

Pneumatic systems facilitating treatment of respiratory insufficiency with alternative use of intermittent positive pressure ventilation positive end expiratory pressure high frequency positive pressure ventilation positive end expiratory pressure continuous positive pressure breathing continuous positive pressure breathing in the adult. Acta Anaesthesiologica Scandinavica Supplementum: 3-147, 1977

Infant ventilator performance effects of altering rate peak inspiratory pressure positive end expiratory pressure and inspiratory expiratory ratio. Clinical Research 31(1): 140A, 1983

Comparison of assisted ventilation and positive end expiratory pressure with intermittent mandatory ventilation and continuous positive airway pressure in adult respiratory distress syndrome patients. American Review of Respiratory Disease 117(4 Part 2): 129, 1978

Best compliance during a decremental, but not incremental, positive end-expiratory pressure trial is related to open-lung positive end-expiratory pressure: a mathematical model of acute respiratory distress syndrome lungs. American Journal of Respiratory and Critical Care Medicine 163(1): 69-78, 2001