A discontinuous buffer system for paper electrophoresis of human hemoglobins



A discontinuous buffer system for paper electrophoresis of human hemoglobins



Clinical Chemistry 5: 446-451



A method for paper electrophoresis of hemoglobins in a discontinuous buffer system is presented. Tris-ethylenediaminetetroacetate (EDTA) buffer 0.12 [image], pH 9.1, is applied to the paper. Barbital buffer 0.06 [image], pH 8.6, is used in the buffer vessels. The discontinuous buffer system enables the detection of hemoglobin A2 in small samples of hemolysate. Resolution of abnormal hemoglobins is superior to that in barbital or Tris-EDTA-borate buffer alone. If offers special advantage for examination of aged samples of hemoglobin. Reasons for the behavior of the hemoglobins in this buffer system are discussed.

(PDF emailed within 1 workday: $29.90)

Accession: 029643861

Download citation: RISBibTeXText

PMID: 13850578


Related references

Electrophoresis on polyacrylamide gel. Application of the "discontinuous electrophoresis" technic to the separation of certain abnormal human hemoglobins. Annali Dell'istituto Superiore di Sanita 3(3): 395-402, 1967

Use of a non-continuous buffer system for starch gel electrophoresis of hemoglobins. Revue Francaise D'etudes Cliniques et Biologiques 3(8): 877-880, 1958

Discontinuous buffer system for polyacrylamide and agarose gel electrophoresis of DNA fragments. Electrophoresis 12(4): 233-240, 1991

A new discontinuous buffer system for the electrophoresis of cationic proteins at near-neutral pH. Analytical Biochemistry 118(1): 194-196, 1981

Utilization of a discontinuous buffer system in the starch-gel electrophoresis of hemoglobin. Rev Francaise Etud Clin Et Biol 3(8): 877-880, 1958

A high pH discontinuous buffer system for resolution of isozymes in starch gel electrophoresis. Stain Technology 64(2): 61-64, 1989

Horizontal gel electrophoresis with sample volumes up to 1.5 mL, using a discontinuous buffer system and automated apparatus. Electrophoresis 16(6): 952-957, 1995

An apparatus for thin layer vertical polyacrylamide gel electrophoresis with discontinuous buffer and gel system. Analytical Biochemistry 63(1): 241-248, 1975

Molecular weight determination of protein dodecyl sulfate complexes by gel electrophoresis in a discontinuous buffer system. Journal of Biological Chemistry 246(20): 6328-6334, 1971

Band width measurement in automated gel electrophoresis apparatus: DNA dispersion in a discontinuous system and in a single buffer. Electrophoresis 16(3): 345-349, 1995

Agarose electrophoresis of DNA in discontinuous buffers, using a horizontal slab apparatus and a buffer system with improved properties. Electrophoresis. 14(3): 179-184, 1993

Agarose electrophoresis of DNA discontinuous buffers, using a horizontal slab apparatus and a buffer system with improved properties. Animal Genetics 25(SUPPL 2): 43, 1994

Information on DNA conformation derived from the Ferguson plot of DNA fragments of up to 9 kb in size, using polyacrylamide gel electrophoresis in a discontinuous buffer system. Electrophoresis 12(4): 241-246, 1991