Isolation and recovery of selected polybrominated diphenyl ethers from human serum and sheep serum coupling reversed-phase solid-phase disk extraction and liquid-liquid extraction techniques with a capillary gas chromatographic electron capture negative ion mass spectrometric determinative technique
Loconto,P.R.; Isenga,D.; O'Keefe,M.; Knottnerus,M.
Journal Of Chromatographic Science: 1, 53-60
2008
ISSN/ISBN: 0021-9665
Accession: 032065943
Polybrominated diphenyl ethers (PBDEs) are isolated and recovered with acceptable percent recoveries from human serum via liquid-liquid extraction and column chromatographic cleanup and fractionation with quantitation using capillary gas chromatography-mass spectrometry with electron capture negative ion and selected ion monitoring. PBDEs are found in unspiked serum.
PDF emailed within 1 workday: $29.90
Related References
Loconto, P.R.; Isenga, D.; O'Keefe, M.; Knottnerus, M. 2008: Isolation and recovery of selected polybrominated diphenyl ethers from human serum and sheep serum: coupling reversed-phase solid-phase disk extraction and liquid-liquid extraction techniques with a capillary gas chromatographic electron capture negative ion mass spectrometric determinative technique Journal of Chromatographic Science 46(1): 53-60Loconto,P.R.; Isenga,D.; O'Keefe,M.; Knottnerus,M. 2008: Isolation and recovery of selected polybrominated diphenyl ethers from human serum and sheep serum coupling reversed-phase solid-phase disk extraction and liquid-liquid extraction techniques with a capillary gas chromatographic electron capture negative ion mass spectrometric determinative technique Journal Of Chromatographic Science: 1, 53-60
Covaci, A.; Voorspoels, S. 2005: Optimization of the determination of polybrominated diphenyl ethers in human serum using solid-phase extraction and gas chromatography-electron capture negative ionization mass spectrometry Journal of Chromatography. B Analytical Technologies in the Biomedical and Life Sciences 827(2): 216-223
Petropoulou, S.-S.E.; Duong, W.; Petreas, M.; Park, J.-S. 2014: Fast liquid chromatographic-tandem mass spectrometric method using mixed-mode phase chromatography and solid phase extraction for the determination of 12 mono-hydroxylated brominated diphenyl ethers in human serum Journal of Chromatography. a 1356: 138-147
Huang, F.; Zhao, Y.; Li, J.; Wu, Y. 2011: Determination of polybrominated diphenyl ethers in human serum using solid-phase extraction and gas chromatography coupled with negative chemical ionization mass spectrometry Se Pu 29(8): 743-749
Zhang, Z.; Rhind, S.M. 2011: Optimized determination of polybrominated diphenyl ethers and polychlorinated biphenyls in sheep serum by solid-phase extraction-gas chromatography-mass spectrometry Talanta 84(2): 487-493
Covaci, A; Pauwels, A; Schepens, P 2000: Determination of Selected Persistent Organochlorine Pollutants in Human Serum by Solid-phase Disk Extraction and Dual-Column Capillary Gas Chromatography with Electron Capture Detection International Journal of Environmental and Analytical Chemistry 76(3): 167-178
Li, J.; Chen, T.; Wang, Y.; Shi, Z.; Zhou, X.; Sun, Z.; Wang, D.; Wu, Y. 2017: Simple and fast analysis of tetrabromobisphenol A, hexabromocyclododecane isomers, and polybrominated diphenyl ethers in serum using solid-phase extraction or QuEChERS extraction followed by tandem mass spectrometry coupled to HPLC and GC Journal of Separation Science 40(3): 709-716
Fontana, A.R.; Lana, N.B.; Martinez, L.D.; Altamirano, J.C. 2010: Ultrasound-assisted leaching-dispersive solid-phase extraction followed by liquid―liquid microextraction for the determination of polybrominated diphenyl ethers in sediment samples by gas chromatography―tandem mass spectrometry Talanta (Oxford) 82(1): 359-366
Fontana, A.R.; Lana, N.B.; Martinez, L.D.; Altamirano, J.C. 2010: Ultrasound-assisted leaching-dispersive solid-phase extraction followed by liquid-liquid microextraction for the determination of polybrominated diphenyl ethers in sediment samples by gas chromatography-tandem mass spectrometry Talanta 82(1): 359-366
Liu, J.; Stewart, J.T. 1997: High-performance liquid chromatographic analysis of ondansetron enantiomers in human serum using a reversed-phase cellulose-based chiral stationary phase and solid-phase extraction Journal of Chromatography. B Biomedical Sciences and Applications 694(1): 179-184
Liu, X.; Li, J.; Zhao, Z.; Zhang, W.; Lin, K.; Huang, C.; Wang, X. 2009: Solid-phase extraction combined with dispersive liquid-liquid microextraction for the determination for polybrominated diphenyl ethers in different environmental matrices Journal of Chromatography. a 1216(12): 2220-2226
Dufresne, C.; Favetta, P.; Paradis, C.; Boulieu, R. 2001: Comparative study of liquid-liquid extraction and solid-phase extraction methods for the separation of sufentanil from plasma before gas chromatographic-mass spectrometric analysis Clinical Chemistry 47(3): 600-602
Papagiannopoulos, M.M.llenthin, A. 2002: Automated sample preparation by pressurized liquid extraction-solid-phase extraction for liquid chromatographic-mass spectrometric investigation of polyphenols in the brewing process Journal of Chromatography A 976(1-2): 345-348
Papagiannopoulos, M.; Mellenthin, A. 2002: Automated sample preparation by pressurized liquid extraction-solid-phase extraction for the liquid chromatographic-mass spectrometric investigation of polyphenols in the brewing process Journal of Chromatography A 976(1-2): 345-348
Salari, H. 1986: Solid-phase extraction and reversed-phase high-performance liquid chromatographic technique for isolation and estimation of platelet activating factor in plasma Journal of Chromatography 382: 89-98
Han, Y.; Jia, X.; Liu, X.; Duan, T.; Chen, H. 2011: Dispersive solid-phase extraction combined with dispersive liquid-liquid microextraction for the determination of polybrominated diphenyl ethers in plastic bottled beverage by GC-MS Journal of Separation Science 34(9): 1047-1054
Vermeij, T.A.; Edelbroek, P.M. 1994: High-performance liquid chromatographic and megabore gas-liquid chromatographic determination of levetiracetam (ucb L059) in human serum after solid-phase extraction Journal of Chromatography. B Biomedical Applications 662(1): 134-139
Mullett, W.M.; Levsen, K.; Lubda, D.; Pawliszy, J. 2002: Bio-compatible in-tube solid-phase microextraction capillary for the direct extraction and high-performance liquid chromatographic determination of drugs in human serum Journal of Chromatography A 963(1-2): 325-334
Mullett, W.M.; Levsen, K.; Lubda, D.; Pawliszyn, J. 2002: Bio-compatible in-tube solid-phase microextraction capillary for the direct extraction and high-performance liquid chromatographic determination of drugs in human serum J. Chromatogr 963(1-2): 325-334