Oximetrically derived mixed venous oxygen saturation does not consistently predict tissue oxygen delivery in patients with ards
Wainz, R.J.; Folk, L.M.; Weg, J.G.
American Review of Respiratory Disease 139(4 Part 2): A313
1989
ISSN/ISBN: 0003-0805 Accession: 032688673
Full Text Article emailed within 1 workday: $29.90
Related References
Suehiro, K.; Tanaka, K.; Matsuura, T.; Funao, T.; Yamada, T.; Mori, T.; Nishikawa, K. 2014: Discrepancy between superior vena cava oxygen saturation and mixed venous oxygen saturation can predict postoperative complications in cardiac surgery patients Journal of Cardiothoracic and Vascular Anesthesia 28(3): 528-533Linge, C.; Kuckelt, W.; Brase, R.; Boehmert, F. 1989: Continuous measurement of the mixed venous oxygen saturation in critically ill patients monitoring of oxygen delivery oxygen consumption Intensivbehandlung 14(4): 162-167
Gawlinski, A.; Henneman, E.A. 1990: Evaluating oxygen delivery and oxygen utilization with mixed venous oxygen saturation monitoring: a case study approach Heart and Lung: the Journal of Critical Care 19(5 Pt 2): 566-570
Zwischenberger, J.B.; Cilley, R.E.; Kirsh, M.M.; Dechert, R.E.; Bartlett, R.H. 1986: Does continuous monitoring of mixed venous oxygen saturation accurately reflect oxygen delivery and oxygen consumption following coronary artery bypass grafting? Surgical Forum 37: 66-68
Svedmyr, A.; Konrad, M.; Wallin, M.; Hallbäck, M.; Lönnqvist, P.-A.; Karlsson, J. 2022: Non-invasive capnodynamic mixed venous oxygen saturation during major changes in oxygen delivery Journal of Clinical Monitoring and Computing 36(5): 1315-1324
Fahey, P.J.; Ahmad, Z.; Vanderwaarf, C.; Harris, K. 1984: Relationship of oxygen delivery and mixed venous oxygen saturation in hypoxemic respiratory failure American Review of Respiratory Disease 129(4 Suppl): A121
Delima, L.G.R.; Wynands, J.E.; Nathan, H.J.; Hynes, M.S.; Dupuis, J.Y.; Bourke, M.E.; Russell, G.N. 1992: Accuracy of mixed venous blood oxygen saturation svo 2 monitoring to detect critical oxygen delivery in patients following hypothermic cardiopulmonary bypass Canadian Journal of Anaesthesia 39(5 Part 2): A28
Lanning, K.M.; Erkinaro, T.M.; Ohtonen, P.P.; Vakkala, M.A.; Liisanantti, J.H.; Ylikauma, L.A.; Kaakinen, T.I. 2022: Accuracy, Precision, and Trending Ability of Perioperative Central Venous Oxygen Saturation Compared to Mixed Venous Oxygen Saturation in Unselected Cardiac Surgical Patients Journal of Cardiothoracic and Vascular Anesthesia 36(7): 1995-2001
Dueck, M.H.; Klimek, M.; Appenrodt, S.; Weigand, C.; Boerner, U. 2005: Trends but not individual values of central venous oxygen saturation agree with mixed venous oxygen saturation during varying hemodynamic conditions Anesthesiology 103(2): 249-257
Mathru, M. 2006: Trends but Not Individual Values of Central Venous Oxygen Saturation Agree With Mixed Venous Oxygen Saturation During Varying Hemodynamic Conditions Yearbook of Anesthesiology and Pain Management 2006: 144-145
Li, D.; Hu, S.; Liang, J.; Han, J.; Wei, W.; Wu, D.; Zhang, L.; Lin, Y.; Han, Z. 2018: Gw29-e0859 Investigation of Central Venous Oxygen Saturation Substitutes Mixed Venous Oxygen Saturation in Postoperative Care of Congenital Heart Disease with Pulmonary Arterial Hypertension Journal of the American College of Cardiology 72(16): C184-C185
Tyree, K.; Tyree, M.; DiGeronimo, R. 2009: Correlation of brain tissue oxygen tension with cerebral near-infrared spectroscopy and mixed venous oxygen saturation during extracorporeal membrane oxygenation Perfusion 24(5): 325-331
Mozina, H.; Podbregar, M. 2010: Near-infrared spectroscopy during stagnant ischemia estimates central venous oxygen saturation and mixed venous oxygen saturation discrepancy in patients with severe left heart failure and additional sepsis/septic shock Critical Care 14(2): R42
Martin, C.; Auffray, J.P.; Badetti, C.; Perrin, G.; Papazian, L.; Gouin, F. 1992: Monitoring of central venous oxygen saturation versus mixed venous oxygen saturation in critically ill patients Intensive Care Medicine 18(2): 101-104
Pasculli, M.; Casadei, E.; Giuntini, L.; Mascolo, A.; Brogi, A. 1991: Optimization of PEEP levels in the treatment of ARDS by means of monitoring the atrial mixed venous oxygen saturation Minerva Anestesiologica 57(12 Suppl): 89-91
Monnet, X.; Julien, F.; Ait-Hamou, N.; Lequoy, M.; Gosset, C.ém.; Jozwiak, M.; Persichini, R.; Anguel, N.; Richard, C.; Teboul, J.-L. 2013: Lactate and venoarterial carbon dioxide difference/arterial-venous oxygen difference ratio, but not central venous oxygen saturation, predict increase in oxygen consumption in fluid responders Critical Care Medicine 41(6): 1412-1420
Turnaoğlu, S.; Tuğrul, M.; Camci, E.; Cakar, N.; Akinci, O.; Ergin, P. 2001: Clinical applicability of the substitution of mixed venous oxygen saturation with central venous oxygen saturation Journal of Cardiothoracic and Vascular Anesthesia 15(5): 574-579
Lampert, R.; Rudolf, B. 1997: Mixed venous oxygen saturation does not correlate with hepatic venous oxygen saturation in patients with MODS Wiener Klinische Wochenschrift 109(Suppl 1): 55
El-Masry, A.; Mukhtar, A.M.; el-Sherbeny, A.M.; Fathy, M.; el-Meteini, M. 2009: Comparison of central venous oxygen saturation and mixed venous oxygen saturation during liver transplantation Anaesthesia 64(4): 378-382
Varpula, M.; Karlsson, S.; Ruokonen, E.; Pettilä, V. 2006: Mixed venous oxygen saturation cannot be estimated by central venous oxygen saturation in septic shock Intensive Care Medicine 32(9): 1336-1343