The effect of an oral cast on the lower stage deposition of dry powder inhaler formulations in a twin impinger
Srichana, T.; Martin, G.P.; Marriott, C.
Pharmaceutical Research (New York) 14(11 Suppl): S141-S142
1997
ISSN/ISBN: 0724-8741 Accession: 033767145
PDF emailed within 1 workday: $29.90
Related References
Mcconville, J.T.; Ditchburn, N.R.; Baichwal, A.R.; Staniforth, J.N. 1997: An in vitro method for evaluation of dry powder inhaler formulations using a novel modified twin stage impinger Pharmaceutical Research (New York) 14(11 Suppl): S133Srichana, T.; Martin, G.P.; Marriott, C. 2000: A human oral-throat cast integrated with a twin-stage impinger for evaluation of dry powder inhalers Journal of Pharmacy and Pharmacology 52(7): 771-778
Geuns, E.R.M.; Toren, J.S.; Barends, D.M.; Bult, A. 1997: Decrease of the stage-2 deposition in the twin impinger during storage of beclomethasone dipropionate dry powder inhalers in controlled and uncontrolled humidities European Journal of Pharmaceutics and Biopharmaceutics 44(2): 187-194
Taki, M.; Ahmed, S.; Marriott, C.; Zeng, X.-M.; Martin, G.P. 2011: The 'stage-by-stage' deposition of drugs from commercial single-active and combination dry powder inhaler formulations European Journal of Pharmaceutical Sciences: Official Journal of the European Federation for Pharmaceutical Sciences 43(4): 225-235
Keller, M.; Trachslin, E.; Gaibrois, U.; Francis, A. 1994: In-vitro assessment of JAGOs dry powder inhaler compared to Diskhaler and Turbuhaler using the twin impinger BP 93 as test device Pharmaceutical Research (New York) 11(10 Suppl): S210
Pitcairn, G.; Reader, S.; Pavia, D.; Newman, S. 2005: Deposition of corticosteroid aerosol in the human lung by Respimat Soft Mist inhaler compared to deposition by metered dose inhaler or by Turbuhaler dry powder inhaler Journal of aerosol medicine: the official journal of the International Society for Aerosols in Medicine 18(3): 264-272
Taki, M.; Marriott, C.; Zeng, X.-M.; Martin, G.P. 2010: Aerodynamic deposition of combination dry powder inhaler formulations in vitro: a comparison of three impactors International Journal of Pharmaceutics 388(1-2): 40-51
Broadhead, J.; Rouan, S.K.E.mond; Rhodes, C.T. 1993: The in vitro deposition of spray dried beta-galactosidase formulations from dry powder inhaler devices Pharmaceutical Research (New York) 10(10 Suppl): S89
Larhrib, H.; Martin, G.P.; Marriott, C.; Prime, D. 2000: Dry powder inhaler formulations The influence of engineered lactose crystals upon the deposition of salbutamol sulphate Journal of Pharmacy and Pharmacology 52(Suppl): 14
Maruyama, S.; Ando, S.; Yonemochi, E. 2020: Application of void forming index (VFI): Detection of the effect of physical properties of dry powder inhaler formulations on powder cohesion International Journal of Pharmaceutics 588: 119766
Miller, N.C.; Marple, V.A.; Schultz, R.K.; Poon, W.S. 1992: Assessment of the twin impinger for size measurement of metered-dose inhaler sprays Pharmaceutical Research 9(9): 1123-1127
Ojima, F.; Shoji, T.; Nakagawa, Y. 1998: Investigation of the effects of puff times and spacer devices on the distribution pattern of a Becotide 100 inhaler in the twin impinger Arerugi 47(1): 19-25
Wong, J.; Kwok, P.C.L.; Noakes, T.; Fathi, A.; Dehghani, F.; Chan, H.-K. 2014: Effect of crystallinity on electrostatic charging in dry powder inhaler formulations Pharmaceutical Research 31(7): 1656-1664
Wei, X.; Hindle, M.; Kaviratna, A.; Huynh, B.K.; Delvadia, R.R.; Sandell, D.; Byron, P.R. 2018: In Vitro Tests for Aerosol Deposition. VI: Realistic Testing with Different Mouth-Throat Models and in Vitro-in Vivo Correlations for a Dry Powder Inhaler, Metered Dose Inhaler, and Soft Mist Inhaler Journal of Aerosol Medicine and Pulmonary Drug Delivery 31(6): 358-371
Lin, Y-Wei.; Wong, J.; Qu, L.; Chan, H-Kim.; Zhou, Q.Tony. 2015: Powder Production and Particle Engineering for Dry Powder Inhaler Formulations Current Pharmaceutical Design 21(27): 3902-3916