Variability comparison of the composite auditory evoked potential index and the bispectral index during propofol-fentanyl anesthesia



Variability comparison of the composite auditory evoked potential index and the bispectral index during propofol-fentanyl anesthesia



Anesthesia and Analgesia 107(1): 117-124



Monitors of hypnotic depth help anesthesiologists to guide the anesthetic. The performance of different monitors depends on several factors, index variability at a steady state of hypnotic depth being one. We compared the recently introduced AAI1.6 with the established bispectral index (BIS), regarding index variability during stable values of propofol effect-site concentration. After ethics committee approval and written informed consent, anesthesia was performed in 40 patients with propofol as the target controlled infusion and fentanyl. Variability of BIS and AAI1.6 was calculated during periods of constant predicted propofol effect compartment concentration and constant levels of surgical stimulation as the median absolute deviation (MAD) from the median value. A variability index was calculated as 1.48*MAD/(threshold - median value), with threshold being the division line between awake and asleep. Threshold crossing time was used to evaluate the performance in predicting return of consciousness. Variability index, however, was significantly larger for the AAI1.6, despite similar absolute variability measured as MAD. Lightening of anesthesia before recovery could be noticed earlier using the BIS than the AAI1.6, although consciousness was detected with a significantly higher Pk-value by the AAI1.6. Variability in relation to the difference between the median index value during anesthesia and the threshold necessary to detect consciousness with high sensitivity is higher for the AAI1.6 than for the BIS. This, as well as the steeper concentration-response function found for AAI1.6, impairs the performance of the AAI1.6 in predicting imminent return of consciousness during decreasing propofol concentrations. However, it makes AAI1.6 well suited to detect consciousness when it has occurred.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 034181141

Download citation: RISBibTeXText

PMID: 18635476

DOI: 10.1213/ane.0b013e31816f1965


Related references

A Comparison in Adolescents of Composite Auditory-Evoked Potential Index and Bispectral Index During Propofol-Remifentanil Anesthesia for Scoliosis Surgery With Intraoperative Wake-Up Test. Survey of Anesthesiology 53(5): 235-236, 2009

A comparison in adolescents of composite auditory evoked potential index and bispectral index during propofol-remifentanil anesthesia for scoliosis surgery with intraoperative wake-up test. Anesthesia and Analgesia 107(5): 1683-1688, 2008

New composite index based on midlatency auditory evoked potential and electroencephalographic parameters to optimize correlation with propofol effect site concentration: comparison with bispectral index and solitary used fast extracting auditory evoked potential index. Anesthesiology 103(3): 500-507, 2005

Comparison of auditory evoked potentials and EEG-Bispectral Index for monitoring of midazolam-fentanyl-propofol anesthesia induction. Anesthesia & Analgesia 94(2S Suppl.): S 155, 2002

ARX-derived auditory evoked potential index and bispectral index during the induction of anesthesia with propofol and remifentanil. Anesthesia and Analgesia 97(1): 139-44, Table of Contents, 2003

Effect of dexmedetomidine on bispectral index and auditory evoked potential index during anesthesia with target controlled infusion of propofol and remifentanyl. Zhejiang Da Xue Xue Bao. Yi Xue Ban 39(1): 84-88, 2010

Comparison of a new composite index based on midlatency auditory evoked potentials and electroencephalographic parameters with bispectral index (BIS) during moderate propofol sedation. European Journal of Anaesthesiology 23(11): 931-936, 2006

Comparison of an auditory evoked potentials index and a bispectral index versus clinical signs for determining the depth of anesthesia produced by propofol or sevoflurane. Revista Espanola de Anestesiologia Y Reanimacion 47(10): 447-457, 2001

The effects of ketamine and rocuronium on the A-line (R) auditory evoked potential index, Bispectral Index, and spectral entropy monitor during steady state propofol and remifentanil anesthesia. Anesthesiology (Hagerstown) 105(6): 1122-1134, 2006

The Effects of Ketamine and Rocuronium on the A-Line?? Auditory Evoked Potential Index, Bispectral Index, and Spectral Entropy Monitor during Steady State Propofol and Remifentanil Anesthesia. Anesthesiology 105(6): 1122-1134, 2006

A comparison of bispectral index and ARX-derived auditory evoked potential index in measuring the clinical interaction between ketamine and propofol anaesthesia. Anaesthesia 58(10): 957-961, 2003

Comparison of bispectral index and composite auditory evoked potential index for monitoring depth of hypnosis in children. Anesthesiology 108(5): 851-857, 2008

Performance of the ARX-derived auditory evoked potential index as an indicator of anesthetic depth: a comparison with bispectral index and hemodynamic measures during propofol administration. Anesthesiology 96(4): 803-816, 2002

Auditory Evoked Potential Index and Bispectral IndexTM during Induction of Anesthesia with Propofol and Remifentanil. Anesthesiology Abstracts of Scientific Papers Annual Meeting ( ): Abstract No A-540, 2002

Performance of bispectral index and auditory evoked potential monitors in detecting loss of consciousness during anaesthetic induction with propofol with and without fentanyl. European Journal of Anaesthesiology 21(10): 807-811, 2005