+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Interruption of cardiopulmonary resuscitation with the use of the automated external defibrillator in out-of-hospital cardiac arrest



Interruption of cardiopulmonary resuscitation with the use of the automated external defibrillator in out-of-hospital cardiac arrest



Annals of Emergency Medicine 42(4): 449-457



The protocol for the use of the automated external defibrillator calls for a period of "hands-off" time, during which no cardiopulmonary resuscitation (CPR) can be performed. We assessed the actual interruption time of CPR during the use of the automated external defibrillator in patients in out-of-hospital cardiac arrest. This study included 184 patients experiencing out-of-hospital cardiac arrest in which an automated external defibrillator was applied by first responders. ECG and voice recordings from the automated external defibrillator were downloaded and analyzed. Start and end times of CPR were recorded, as were intervals measured from the recordings concerning the programmed interruption time and the interruption time related to performance. The automated external defibrillators were connected for a median time of 4 minutes 47 seconds (range 31 to 1,404 seconds). CPR was performed during 45%+/-15% (mean+/-SD) of the connected time or until return of spontaneous circulation. During the automated external defibrillator connection time in the 96 patients with a shockable rhythm, CPR was performed 36%+/-20% of the time. Programmed interruption of CPR took 40%+/-15% of the automated external defibrillator connection time, and no CPR was performed related to performance during 23%+/-15% of the time. A palpable pulse was never present immediately after a shock, and return of spontaneous circulation was observed in 3 of 184 patients before arrival of the ambulance. Ultimately, return of spontaneous circulation occurred in 87 of 184 patients. First responders using automated external defibrillator voice prompts provide CPR less than half the time that the automated external defibrillator is connected to the patient. Technical improvements in automated external defibrillator rhythm analysis, more efficient resuscitation algorithms, and first-responder education could increase CPR delivery and, perhaps, improve outcome.

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 035164499

Download citation: RISBibTeXText

PMID: 14520315


Related references

Cardiopulmonary resuscitation alone vs. cardiopulmonary resuscitation plus automated external defibrillator use by non-healthcare professionals: a meta-analysis on 1583 cases of out-of-hospital cardiac arrest. Resuscitation 76(2): 226-232, 2008

DEFI 2005: a randomized controlled trial of the effect of automated external defibrillator cardiopulmonary resuscitation protocol on outcome from out-of-hospital cardiac arrest. Circulation 121(14): 1614-1622, 2010

Minimal interruption of cardiopulmonary resuscitation for a single shock as mandated by automated external defibrillations does not compromise outcomes in a porcine model of cardiac arrest and resuscitation. Critical Care Medicine 36(11): 3048-3053, 2008

Community-based automated external defibrillator only resuscitation for out-of-hospital cardiac arrest patients. American Heart Journal 172: 192-200, 2016

Out-of-hospital cardiac arrests occurring in southern Ontario health care clinics: bystander cardiopulmonary resuscitation and automated external defibrillator use. Canadian Family Physician Medecin de Famille Canadien 56(6): E213, 2010

Early cardiopulmonary resuscitation and use of Automated External Defibrillators by laypersons in out-of-hospital cardiac arrest using an SMS alert service. Resuscitation 82(10): 1273-1278, 2011

Automated cardiopulmonary resuscitation using a load-distributing band external cardiac support device for in-hospital cardiac arrest: a single centre experience of AutoPulse-CPR. International Journal of Cardiology 180: 7-14, 2015

Community-Wide Dissemination of Bystander Cardiopulmonary Resuscitation and Automated External Defibrillator Use Using a 45-Minute Chest Compression-Only Cardiopulmonary Resuscitation Training. Journal of the American Heart Association 8(1): E009436, 2019

How to use an automated external defibrillator following out-of-hospital cardiac arrest. Nursing Standard 1987) 31(32): 38-43, 2017

Evaluating the quality of prehospital cardiopulmonary resuscitation by reviewing automated external defibrillator records and survival for out-of-hospital witnessed arrests. Resuscitation 64(2): 163-169, 2005

Impact of Automated External Defibrillator as a Recent Innovation for the Resuscitation of Cardiac Arrest Patients in an Urban City of Japan. Journal of Emergencies Trauma and Shock 11(3): 217-220, 2018

Automated external defibrillator use for in-hospital cardiac arrest is not associated with improved survival. Evidence-Based Medicine 16(3): 95-96, 2011

Pre-hospital cardiac arrest treated successfully with automated external defibrillator. Kardiologia Polska 75(6): 618, 2017

Automated external defibrillator and operator performance in out-of-hospital cardiac arrest. Resuscitation 118: 140-146, 2017

Out-of-hospital cardiac arrest. Mechanisms and treatment with automated external defibrillator. Ugeskrift for Laeger 165(10): 1009-1012, 2003