EurekaMag.com logo
+ Site Statistics
References:
53,623,987
Abstracts:
29,492,080
+ Search Articles
+ Subscribe to Site Feeds
EurekaMag Most Shared ContentMost Shared
EurekaMag PDF Full Text ContentPDF Full Text
+ PDF Full Text
Request PDF Full TextRequest PDF Full Text
+ Follow Us
Follow on FacebookFollow on Facebook
Follow on TwitterFollow on Twitter
Follow on LinkedInFollow on LinkedIn

+ Translate

Multi-slice biopsy with single slice computed tomography



Multi-slice biopsy with single slice computed tomography



Official Gazette of the United States Patent & Trademark Office Patents 1238(1), Sep 5



A method for controlling operation of a pre-patient collimator to sweep x-rays across a patient are described. Particularly, and rather than shuttling the patient back and forth to obtain scans of different locations, the x-ray beams are swept across the patient by adjusting the positions of the pre-patient collimator. The x-ray beam deviates from the nominal position in z (z is the axis perpendicular to the scan plane). Since the pre-patient collimator is very light, and since the amount of motion in collimator is very small due to the large magnification, the x-ray beam deflection can occur instantaneously without any ramp-up or ramp down periods. Therefore, a 100% duty cycle can be achieved and the image update rate may be reduced. Also, no modification to the reconstruction process is necessary. The nominal slice location for each reconstructed image can be easily estimated by the centroid of the beam location during the date acquisition.

(PDF 0-2 workdays service: $29.90)

Accession: 035349545

Download citation: RISBibTeXText



Related references

Investigation of the slice sensitivity profile for step-and-shoot mode multi-slice computed tomography. Medical Physics 28(4): 491-500, 2001

Assessment of left ventricular volumes and ejection fraction with 16-slice multi-slice computed tomography; comparison with 2D-echocardiography. International Journal of Cardiology 116(2): 201-205, 2006

Modulation transfer functions of single-slice and dual-slice computed tomography scanners. Medical Physics 23(11): 1863-1864, 1996

Prognostic value of multi-slice computed tomography and gated single photon emission computed tomography in a cohort of 426 patients with known or suspected coronary artery disease. 2007

Single-slice and multi-slice computerized tomography: dosimetric comparison with diagnostic reference dose levels. La Radiologia Medica 102(4): 262-265, 2001

Cochlear Implant Electrode Localization Using an Ultra-High Resolution Scan Mode on Conventional 64-Slice and New Generation 192-Slice Multi-Detector Computed Tomography. Otology & Neurotology 38(7): 978-984, 2017

Added value of combined simultaneous lung ventilation-perfusion single-photon emission computed tomography/multi-slice-computed tomography angiography in two patients suspected of having acute pulmonary embolism. Clinical Respiratory Journal 1(1): 52-55, 2010

Multi-slice computed tomography in dilated cardiomyopathy: comparison with myocardial biopsy, diagnostic and prognostic value. European Heart Journal 34(Suppl 1): P4210-P4210, 2013

Single- and multi-slice spiral computed tomography of the paediatric kidney. European Journal of Radiology 43(2): 139-145, 2002

Computed tomography slice-by-slice target-volume delineation for stereotactic proton irradiation of large intracranial arteriovenous malformations: An iterative approach using, angiography, computed tomography, and magnetic resonance imaging. International Journal of Radiation Oncology Biology Physics 35(3): 555-564, 1996

Dual-slice spiral versus single-slice spiral scanning: comparison of the physical performance of two computed tomography scanners. Medical Physics 23(2): 205-220, 1996

High-resolution computed tomography with single-slice computed tomography and 16-channel multidetector computed tomography: a comparison regarding visibility and motion artifacts. Acta Radiologica 48(9): 956-961, 2007

Slice sensitivity profile and image pixel noise of multi-slice spiral CT in comparison with single slice spiral CT. Rofo 171(3): 219-225, 1999

Quality of coronary arterial 320-slice computed tomography images compared with 16-slice computed tomography images in subjects with chronic atrial fibrillation. International Journal of Cardiology 149(2): E90-E93, 2012

High correlation between single slice area and multi-slice volume imaging of the abdominal region despite high intra-subject between-slice variability in visceral adipose tissue. FASEB Journal 17(4-5): Abstract No 452 5, March, 2003