Multi-wavelength reflectance pulse oximetry



Multi-wavelength reflectance pulse oximetry



Anesthesia and Analgesia 94(1 Suppl): S26-S30



The performance of current reflectance pulse oximeters is hindered by poor signal-to-noise ratio. To overcome this problem a new reflectance oximeter has been developed with a sensor which consists of three LEDs and two continuous photodetector rings placed equidistant from the center of the LEDs. In addition, ultra low noise electronics and adaptive algorithm assure improved performance. A validation study was performed on 10 healthy volunteers. Sensors were placed on several sites and measurements were compared to reference arterial blood samples. During the study progressive hypoxemia was induced by lowering the inspired oxygen concentration (FiO2) to 10%, followed by a recovery phase. Twelve blood samples were taken during each cycle, yielding a total of 120 measured data points. Data from randomly selected 5 subjects was used for calibration and subsequently tested on the other 5 subjects. Results proved to be well within clinically acceptable boundaries for all 3 sampling sites with high correlation (R2 > 0.9) and SD around 2%. In conclusion, a new 3 wavelength reflectance pulse oximeter with unique sensor geometry and improved algorithms provides enhanced performance and is less susceptible to poor signal to noise conditions when compared to existing reflectance oximetry systems.

(PDF emailed within 1 workday: $29.90)

Accession: 035349649

Download citation: RISBibTeXText

PMID: 11900033


Related references

Notes on the apparent discordance of pulse oximetry and multi-wavelength haemoglobin photometry. Acta Anaesthesiologica Scandinavica. 39(suppl. 107): 49-52, 1995

Pulse oximetry in the air rescue service. 2: Methods of increasing the stability of pulse oximetry measurements--ECG-synchronized pulse oximetry and adhesive sensors. Anasthesiologie, Intensivmedizin, Notfallmedizin, Schmerztherapie 28(3): 174-178, 1993

The pulse in reflectance pulse oximetry: modeling and experimental studies. Journal of Clinical Monitoring and Computing 18(4): 289-299, 2005

Multiple wavelength reflectance oximetry in peripheral tissues. Advances in Experimental Medicine and Biology 94: 69-75, 1977

Probe Wavelength for Pulse CO-Oximetry. Anesthesiology Abstracts of Scientific Papers Annual Meeting ( ): Abstract No A-557, 2002

Reflectance pulse oximetry in neonates. European Journal of Obstetrics & Gynecology & Reproductive Biology 61(2): 117-122, 1995

Wavelength selection for low-saturation pulse oximetry. IEEE Transactions on Bio-Medical Engineering 44(3): 148-158, 1997

Multi-wavelength synchronous pulse burst generation with a wavelength selective switch. Optics Express 16(14): 10152-7, 2008

Fetal reflectance pulse oximetry during labour. Zeitschrift fuer Geburtshilfe und Perinatologie 198(2): 67-71, 1994

Problems with forehead reflectance pulse oximetry. Respiratory Care 51(7): 715-716, 2006

Multilayer modeling of reflectance pulse oximetry. IEEE Transactions on Bio-Medical Engineering 52(2): 153-159, 2005

Reflectance pulse oximetry in fetal lambs. Pediatric Research 31(3): 266-269, 1992

Accuracy of two wavelength pulse oximetry in neonates and infants. Pediatric Pulmonology 6(3): 180-182, 1989

How tissue optics influences reflectance pulse oximetry. Advances in Experimental Medicine and Biology 388: 117-132, 1996

Esophageal pulse oximetry utilizing reflectance photoplethysmography. IEEE Transactions on Bio-Medical Engineering 49(11): 1360-1368, 2002