Performance of VITEK-2 Compact and overnight MicroScan panels for direct identification and susceptibility testing of Gram-negative bacilli from positive FAN BacT/ALERT blood culture bottles



Performance of VITEK-2 Compact and overnight MicroScan panels for direct identification and susceptibility testing of Gram-negative bacilli from positive FAN BacT/ALERT blood culture bottles



Clinical Microbiology and Infection 16(2): 137-140



We describe the reliability of the VITEK-2 Compact and overnight MicroScan panels for direct identification and susceptibility testing from the BacT/ALERT blood culture system when using FAN (FA and FN) bottles. A simple procedure, in two centrifugation steps, was designed to remove the charcoal particles present in FA and FN bottles. A total of 113 positive blood cultures showing Gram-negative rods were investigated. Enterobacteriaceae were isolated in 104 cases, and Pseudomonas aeruginosa in nine. The MicroScan system correctly identified 106 (93.8%) of the 113 isolates. The seven identification errors included P. aeruginosa (three), Enterobacter cloacae (one), Escherichia coli (one), Klebsiella oxytoca (one), and Klebsiella pneumoniae (one). The VITEK-2 system correctly identified 109 (96.5%) of the 113 samples obtained directly from the blood culture bottles. The four unidentified isolates were Enterobacter cloacae (two), Escherichia coli (one), and P. aeruginosa (one). MicroScan yielded 4/779 (0.5%) very major errors and 28/2825 (0.9%) minor errors. VITEK-2 yielded 2/550 (0.36%) very major errors, 1/1718 (0.05%) major error, and 32/2373 (1.3%) minor errors. Both systems provided excellent identification (correlation of >90%) and susceptibility (correlation of >98%) results. The average times required to obtain identification and susceptibility results using the direct test applied to the VITEK-2 Compact system were 4.57+or-1.37 h and 6.52+or-1.64 h, respectively. The VITEK-2 compact system provided results on the same day that the blood culture was found to be positive.

(PDF emailed within 0-6 h: $19.90)

Accession: 035477088

Download citation: RISBibTeXText

PMID: 19778301

DOI: 10.1111/j.1469-0691.2009.02907.x



Related references

Direct susceptibility testing from positive BacT/Alert blood culture specimens using MicroScan overnight and rapid panels. Abstracts of the General Meeting of the American Society for Microbiology 96(0): 56, 1996

Comparative evaluation of Vitek 2 identification and susceptibility testing of Gram-negative rods directly and isolated from BacT/ALERT-positive blood culture bottles. European Journal of Clinical Microbiology & Infectious Diseases 31(5): 663-669, 2012

Direct susceptibility testing with positive BacT/Alert blood cultures by using MicroScan overnight and rapid panels. Journal of Clinical Microbiology 36(7): 2052-2056, 1998

Evaluation of the Vitek System for direct susceptibility testing of positive BacT/alert FAN blood culture bottles. Abstracts of the Interscience Conference on Antimicrobial Agents & Chemotherapy 37: 91, 1997

Direct bacterial identification from positive BacT/Alert blood cultures using MicroScan overnight and rapid panels. Diagnostic Microbiology & Infectious Disease. 32(1): 21-26,., 1998

Direct susceptibility testing of positive BacT/Alert blood culture bottles with AutoSCAN-W/A rapid combo panels. Abstracts of the General Meeting of the American Society for Microbiology 93(0): 457, 1993

Rapid identification and susceptibility testing of Gram-positive cocci in BacT/ALERT blood cultures by direct inoculation into the Vitek 2 system. Revista Espanola de Quimioterapia 24(3): 131-135, 2012

Direct bacterial identification from positive BacT/Alert blood culture specimens using MicroScan overnight and rapid. Abstracts of the General Meeting of the American Society for Microbiology 97(0): 195, 1997

Evaluation of wider system for direct identification and antimicrobial susceptibility testing of gram-negative bacilli from positive blood culture bottles. European Journal of Clinical Microbiology & Infectious Diseases 21(9): 693-695, 2002

Identification and susceptibility testing of gram-negative bacilli by direct inoculation from positive BACTEC blood culture bottles into the BD PHOENIX automated microbiology system. 2005

Comparison of auto scan w a baxter microscan division and vitek ams vitek systems inc for antimicrobial susceptibility testing of gram negative bacilli and gram positive cocci. Abstracts of the General Meeting of the American Society for Microbiology 91: 364, 1991

Direct susceptibility testing from positive blood culture specimens into MicroScan rapid and dried overnight susceptibility panels. Abstracts of the General Meeting of the American Society for Microbiology 95(0): 60, 1995

Identification and susceptibility testing of microorganism by direct inoculation from positive blood culture bottles by combining MALDI-TOF and Vitek-2 Compact is rapid and effective. Journal of Infection 65(6): 513-520, 2013

Evaluation of the VITEK 2 system for rapid direct identification and susceptibility testing of gram-negative bacilli from positive blood cultures. Journal of Clinical Microbiology 41(10): 4705-4707, 2003

Direct inoculation method using BacT/ALERT 3D and BD Phoenix System allows rapid and accurate identification and susceptibility testing for both Gram-positive cocci and Gram-negative rods in aerobic blood cultures. Diagnostic Microbiology and Infectious Disease 73(2): 129-134, 2012