+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Magnetic resonance lymphography at 3T: a promising noninvasive approach to characterise inguinal lymphatic vessel leakage



Magnetic resonance lymphography at 3T: a promising noninvasive approach to characterise inguinal lymphatic vessel leakage



European Journal of Vascular and Endovascular Surgery 43(1): 106-111



To explore the feasibility of using 3T high-resolution MR lymphangiography to characterize inguinal lymphatic vessel leakage (LVL). Sixteen patients with known inguinal LVL underwent 3T MR lymphangiography and T(2)-weighted imaging. The presence or absence of inguinal LVL and the responsible lymphatic vessels were determined using the above imaging modalities and confirmed by surgical procedure. Afterwards, fifteen patients with recurring LVL following conservative treatment were referred to surgical intervention. Specific inguinal LVL enhancement patterns and leaking lymphatic vessels were detected in 15 of 16 patients. Compared to the SNR of enhanced lymph nodes, that of the enhanced LVL was significantly greater (t = 7.149, p < 0.01), thereby making it possible to differentiate between LVL sites and enhancing inguinal lymph nodes. Furthermore, the steepest contrast enhancement curve slope of enhanced LVL was lower than that of enhanced lymph nodes (t = -2.860, p = 0.02). After MR diagnosis, 15 patients successfully underwent open exploration and ligation of the leaking lymphatic vessel. Clinical follow-up did not demonstrate recurrence of lymphatic fluid in the groin. High-resolution MR lymphangiography combined with T(2)-weighted imaging is a promising approach to identifying specific features of lymphatic vessel leakage in the groin.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 036232248

Download citation: RISBibTeXText

PMID: 22000340

DOI: 10.1016/j.ejvs.2011.09.007


Related references

Treatment of recurrent inguinal lymphocele by lymphatic leakage mapping and subsequent ligation of lymphatic vessel endings: a case report. Gynecologic Oncology 84(1): 155-156, 2002

Magnetic resonance lymphography demonstrates spontaneous lymphatic disruption and regeneration in obstructive lymphedema. Lymphology 46(2): 56-63, 2013

Assessment of The Lymphatic System of the Genitalia Using Magnetic Resonance Lymphography Before and After Treatment of Male Genital Lymphedema. Medicine 95(21): E3755, 2016

Functional investigations of exercising muscle: a noninvasive magnetic resonance spectroscopy-magnetic resonance imaging approach. Cellular and Molecular Life Sciences 61(9): 1001-1015, 2004

An experimental study of the cervical lymphatic imaging in interstitial magnetic resonance lymphography of tongue using Dextran-DTPA-Gd. Shanghai Kou Qiang Yi Xue 21(3): 283-286, 2012

Visualization of lymphatic basin from the tumor using magnetic resonance lymphography with superparamagnetic iron oxide in patients with thoracic esophageal cancer. Journal of Computer Assisted Tomography 30(2): 270-275, 2006

Potential of magnetic resonance lymphography with intrapulmonary injection of gadopentetate dimeglumine for visualization of the pulmonary lymphatic basin in dogs: preliminary results. Investigative Radiology 38(11): 679-689, 2003

Effectiveness of therapeutic lymphography on lymphatic leakage. Acta Radiologica 52(3): 305-311, 2011

The lymphatic vessel system and lymphography in birds (1). Tierarztliche Praxis 11(4): 469-476, 1983

16-Slice multidetector-row computed tomography and magnetic resonance imaging for the in vivo and noninvasive assessment of vessel areas and diameters. Journal of the American College of Cardiology 43(5 Suppl. A): 314A, 2004

Technical facilitation of lymphatic vessel puncture in lymphography. Rontgenpraxis; Zeitschrift für Radiologische Technik 38(2): 65-67, 1985

Nuclear magnetic resonance: a noninvasive approach to cancer. Hospital Practice 12: 63-70, 1977

Noninvasive coronary vessel wall and plaque imaging with magnetic resonance imaging. Circulation 102(21): 2582-2587, 2000

In vitro/in vivo comparison of drug release and polymer erosion from biodegradable P(FAD-SA) polyanhydrides--a noninvasive approach by the combined use of electron paramagnetic resonance spectroscopy and nuclear magnetic resonance imaging. Pharmaceutical Research 14(6): 820-826, 1997