+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Fast T1 mapping determined using incomplete inversion recovery look-locker 3D balanced SSFP acquisition and a simple two-parameter model fit



Fast T1 mapping determined using incomplete inversion recovery look-locker 3D balanced SSFP acquisition and a simple two-parameter model fit



Journal of Magnetic Resonance Imaging 35(6): 1437-1444



To evaluate a fast T1 mapping technique using incomplete inversion recovery 3D balanced steady-state free precession acquisition along with a two-parameter model fit. Using Bloch simulations, we explored the two-parameter model fit for data acquired using such an acquisition scheme. The parameter space over which the fit holds good was determined through simulations. A linear correction was derived for the R1* (1/T1*) values so determined. Two phantoms and six volunteers were scanned using the described technique. Comparison scans using full recovery as well as gold standard inversion recovery spin echo were also performed. The two-parameter fit works exceedingly well over a large parameter space. T1 values in the phantoms showed an error of 4.9% and 39% before correction and 0.9% and 1.6% after correction. For the six volunteers, error in T1 value was 5.3% for white matter (WM) and 2.4% for gray matter (GM) after correction, while it was 11.2% and 18.2% before correction. The work presented here allows for T1 map determination with higher resolution and shorter acquisition time than previously possible. The technique is especially well suited for GM/WM T1 mapping.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 036326156

Download citation: RISBibTeXText

PMID: 22282318

DOI: 10.1002/jmri.23576


Related references

Three-dimensional T(1), T(2) and proton density mapping with inversion recovery balanced SSFP. Magnetic Resonance Imaging 28(9): 1374-1382, 2010

Simultaneous T1 and T2 quantification of the myocardium using cardiac balanced-SSFP inversion recovery with interleaved sampling acquisition (CABIRIA). Magnetic Resonance in Medicine 74(2): 365-371, 2015

Consideration of slice profiles in inversion recovery Look-Locker relaxation parameter mapping. Magnetic Resonance Imaging 32(8): 1021-1030, 2014

Automated brain tissue segmentation based on fractional signal mapping from inversion recovery Look-Locker acquisition. Neuroimage 52(4): 1347-1354, 2010

Fast high-resolution T1 mapping using inversion-recovery Look-Locker echo-planar imaging at steady state: optimization for accuracy and reliability. Magnetic Resonance in Medicine 61(4): 899-906, 2009

An analytical model which determines the apparent T 1 for Modified Look-Locker Inversion Recovery - Analysis of the longitudinal relaxation under the influence of discontinuous balanced (classical MOLLI) and spoiled gradient echo readouts. Zeitschrift für Medizinische Physik 28(2): 150-157, 2018

Fast chemical shift mapping with multiecho balanced SSFP. Magma 19(5): 267-273, 2006

Inversion group (IG) fitting: A new T1 mapping method for modified look-locker inversion recovery (MOLLI) that allows arbitrary inversion groupings and rest periods (including no rest period). Magnetic Resonance in Medicine 75(6): 2332-2340, 2016

Fast multiecho balanced SSFP metabolite mapping of (1)H and hyperpolarized (13)C compounds. Magma 22(4): 251-256, 2009

Balanced SSFP-like steady-state imaging using small-tip fast recovery with a spectral prewinding pulse. Magnetic Resonance in Medicine 75(2): 839-844, 2016

Fast high-resolution brain imaging with balanced SSFP: Interpretation of quantitative magnetization transfer towards simple MTR. Neuroimage 59(1): 202-211, 2012

Flexible cardiac T1 mapping using a modified Look-Locker acquisition with saturation recovery. Magnetic Resonance in Medicine 67(3): 622-627, 2012

Modified Look-Locker inversion recovery (MOLLI) for high-resolution T1 mapping of the heart. Magnetic Resonance in Medicine 52(1): 141-146, 2004

Improved segmented modified Look-Locker inversion recovery T1 mapping sequence in mice. Plos one 12(11): E0187621, 2017

Shortened Modified Look-Locker Inversion recovery (ShMOLLI) for clinical myocardial T1-mapping at 1.5 and 3 T within a 9 heartbeat breathhold. Journal of Cardiovascular Magnetic Resonance 12: 69, 2010