+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Comparison of three-dimensional pseudo-continuous arterial spin labeling perfusion imaging with gradient-echo and spin-echo dynamic susceptibility contrast MRI



Comparison of three-dimensional pseudo-continuous arterial spin labeling perfusion imaging with gradient-echo and spin-echo dynamic susceptibility contrast MRI



Journal of Magnetic Resonance Imaging 39(2): 427-433



To compare the relative cerebral blood flow (CBF) obtained by pseudo-continuous arterial spin labeling sequence incorporated with volumetric fast spin-echo readout (3D-PCASL) with those by gradient-echo (GE) and spin-echo (SE) dynamic susceptibility contrast (DSC) MRI. Thirty patients with various neurological diseases participated in this study. In addition to 3D-PCASL, 15 patients received GE-DSC and the others received SE-DSC imaging on a 3 Tesla scanner. A cortical gray matter (GM) to white matter (WM) and a thalamus (TM) to WM CBF ratio were determined from each perfusion scan. In addition, histograms of relative CBF distributions were obtained from each method for comparison. Significant correlations of CBF ratios were found between 3D-PCASL and the two DSC methods (P < 0.05). The 3D-PCASL resulted in GM/WM CBF ratios similar to SE-DSC but significantly smaller than GE-DSC (P = 2.3 × 10(-7) ). TM/WM CBF ratio obtained by 3D-PCASL was significantly smaller than those by GE- and SE-DSC (P = 4.1 × 10(-7) and 1.2 × 10(-6) , respectively). The histogram of relative CBF maps obtained from SE-DSC, after applied spatial smoothing, agreed well with that from 3D-PCASL. This study suggested that perfusion images obtained from 3D-PCASL exhibited significant correlations with DSC-MRI, with greater microvascular weighting like SE-DSC.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 036894045

Download citation: RISBibTeXText

PMID: 23677620

DOI: 10.1002/jmri.24178


Related references

Test-retest reliability of 3D spiral fast-spin-echo pseudo-continuous arterial spin labeling for cerebral perfusion imaging of subcortical gray matter in healthy adults. Nan Fang Yi Ke Da Xue Xue Bao 37(9): 1242-1247, 2017

Three-dimensional Pseudo-continuous Arterial Spin-labeling Using Turbo-spin Echo with Pseudo-steady State Readout: A Comparison with Other Major Readout Methods. Magnetic Resonance in Medical Sciences 2018, 2018

Perfusion MRI of the human brain with dynamic susceptibility contrast: gradient-echo versus spin-echo techniques. Journal of Magnetic Resonance Imaging 12(3): 381-387, 2000

Dynamic hysteresis between gradient echo and spin echo attenuations in dynamic susceptibility contrast imaging. Magnetic Resonance in Medicine 69(4): 981-991, 2013

Comparison of fast turbo-spin-echo and gradient- and spin-echo sequences as well as echo planar imaging with conventional spin-echo sequences in MRI of focal liver lesions at 1.0 tesla. Rofo 165(2): 137-143, 1996

Tumor recurrence versus treatment effects in glioma: A comparative study of three dimensional pseudo-continuous arterial spin labeling and dynamic susceptibility contrast imaging. Medicine 96(50): E9332, 2018

Perfusion imaging of meningioma by using continuous arterial spin-labeling: comparison with dynamic susceptibility-weighted contrast-enhanced MR images and histopathologic features. Ajnr. American Journal of Neuroradiology 27(1): 85-93, 2006

MR contrast of ferritin and hemosiderin in the brain: comparison among gradient-echo, conventional spin-echo and fast spin-echo sequences. European Journal of Radiology 48(3): 230-236, 2003

Perfusion-sensitive MR imaging of gliomas: comparison between gradient-echo and spin-echo echo-planar imaging techniques. Ajnr. American Journal of Neuroradiology 22(7): 1306-1315, 2001

Slice accelerated gradient-echo spin-echo dynamic susceptibility contrast imaging with blipped CAIPI for increased slice coverage. Magnetic Resonance in Medicine 72(3): 770-778, 2015

MR imaging of hemorrhagic brain lesions: a comparison of dual-echo gradient- and spin-echo and fast spin-echo techniques. Ajr. American Journal of Roentgenology 171(3): 797-802, 1998

Functional localization in the human brain: Gradient-Echo, Spin-Echo, and arterial spin-labeling fMRI compared with neuronavigated TMS. Human Brain Mapping 32(3): 341-357, 2011

Perfusion MRI of brain tumours: a comparative study of pseudo-continuous arterial spin labelling and dynamic susceptibility contrast imaging. Neuroradiology 52(4): 307-317, 2010

A linear mixed perfusion model for tissue partial volume correction of perfusion estimates in dynamic susceptibility contrast MRI: Impact on absolute quantification, repeatability, and agreement with pseudo-continuous arterial spin labeling. Magnetic Resonance in Medicine 77(6): 2203-2214, 2016

Three-dimensional arterial spin labeling imaging and dynamic susceptibility contrast perfusion-weighted imaging value in diagnosing glioma grade prior to surgery. Experimental and Therapeutic Medicine 13(6): 2691-2698, 2017