Evaluation of intraorbital prosthetic pigmentation using 0.3 and 1.5 Tesla magnetic resonance imaging and computed tomography



Evaluation of intraorbital prosthetic pigmentation using 0.3 and 1.5 Tesla magnetic resonance imaging and computed tomography



Veterinary Ophthalmology 17(3): 184-189



To investigate the magnetic susceptibility artifact associated with pigmented intraorbital prosthetics when performing magnetic resonance imaging (MRI) and computed tomography (CT). Potential artifact reduction techniques were also investigated. Prospective study. Five different-colored 20-millimeter small animal silicone intraorbital prosthetics and two equine prosthetics were evaluated using 0.3 and 1.5 Tesla (T) MRI and CT. MRI sequences included T1- (T1WI) and T2-weighted spin echo (T2WI), T2 gradient echo (T2*), short tau inversion recovery (STIR), and fluid-attenuated inversion recovery (FLAIR). When present, artifact size was measured using computerized software by three separate observers. Artifact reduction techniques included alterations in receiver bandwidth, field of view, slice thickness, and matrix size. The ferrous brown-pigmented prosthetic resulted in a magnetic susceptibility artifact with MRI. No artifact was observed on CT images. Interobserver variability was not statistically significant. For both the 0.3T and 1.5T MRI, the T2* sequence exhibited the largest artifact surface area followed by T2WI, T1WI, STIR, and FLAIR. Decreasing slice thickness showed a decrease in artifact size; however, this difference was not statistically significant. The ferrous substances in the brown intraorbital prosthetic resulted in a significant magnetic susceptibility artifact when performing MRI. Artifact reduction techniques did not significantly decrease artifact surface area. The use of ferrous brown-pigmented prosthetics and their potential to affect future MR imaging studies should be adequately discussed with pet owners.

(PDF emailed within 0-6 h: $19.90)

Accession: 036923888

Download citation: RISBibTeXText

PMID: 23738745

DOI: 10.1111/vop.12064


Related references

Visibility of Different Intraorbital Foreign Bodies Using Plain Radiography, Computed Tomography, Magnetic Resonance Imaging, and Cone-Beam Computed Tomography: An In Vitro Study. Canadian Association of Radiologists Journal 68(2): 194-201, 2016

Interobserver variability of 3.0-tesla and 1.5-tesla magnetic resonance imaging/computed tomography fusion image-based post-implant dosimetry of prostate brachytherapy. Journal of Radiation Research 2019, 2019

Image Distortions on a Plastic Interstitial Computed Tomography/Magnetic Resonance Brachytherapy Applicator at 3 Tesla Magnetic Resonance Imaging and Their Dosimetric Impact. International Journal of Radiation Oncology, Biology, Physics 99(3): 710-718, 2018

Intraorbital wooden foreign body detected by computed tomography and magnetic resonance imaging. Neuroradiology Journal 30(1): 88-91, 2016

Usefulness of combining sequentially acquired gadobenate dimeglumine-enhanced magnetic resonance imaging and resovist-enhanced magnetic resonance imaging for the detection of hepatocellular carcinoma: comparison with computed tomography hepatic arteriography and computed tomography arterioportography using 16-slice multidetector computed tomography. Journal of Computer Assisted Tomography 31(5): 702-711, 2007

Is Computed Tomography an Adequate Imaging Modality for the Evaluation of Juvenile Ossifying Fibroma? A Comparison of 2 Imaging Modalities (Computed Tomography and Magnetic Resonance Imaging). Journal of Oral and Maxillofacial Surgery 73(7): 1304-1313, 2015

Imaging techniques for measuring adipose-tissue distribution in the abdomen: a comparison between computed tomography and 1.5-tesla magnetic resonance spin-echo imaging. Radiation Medicine 16(2): 99-107, 1998

Assessment of primary gynecologic malignancies comparison of 0.15 tesla resistive magnetic resonance imaging with computed tomography. AJR (American Journal of Roentgenology) 143(6): 1249-1257, 1984

Radiography, computed tomography and magnetic resonance imaging at 0.5 Tesla of mechanically induced osteoarthritis in rabbit knees. Brazilian Journal of Medical and Biological Research 37(4): 493-501, 2004

Comparison of Computed Tomography, Magnetic Resonance Imaging, and Positron Emission Tomography and Computed Tomography for the Evaluation Bone Invasion in Upper and Lower Gingival Cancers. Journal of Oral and Maxillofacial Surgery 2019, 2019

Simultaneous 68 Ga DOTATATE Positron Emission Tomography/Magnetic Resonance Imaging in Meningioma Target Contouring: Feasibility and Impact Upon Interobserver Variability Versus Positron Emission Tomography/Computed Tomography and Computed Tomography/Magnetic Resonance Imaging. Clinical Oncology ) 29(7): 448-458, 2017

Magnetic resonance imaging of esophageal carcinoma with ecg gating at 15 tesla experience with 25 patients correlated to computed tomography and endosonography. Journal of Cancer Research & Clinical Oncology 116(SUPPL PART 1): 559, 1990

Superior orbital fissure syndrome caused by intraorbital spread of a cutaneous squamous cell carcinoma and not detected on computed tomography and magnetic resonance imaging. Japanese Journal of Ophthalmology 41(2): 104-110, 1997

Evaluation of efficacy of transcatheter arterial chemoembolization combined with computed tomography-guided radiofrequency ablation for hepatocellular carcinoma using magnetic resonance diffusion weighted imaging and computed tomography perfusion imaging: A prospective study. Medicine 96(3): E5518, 2017

Assessment of safety and interference issues of radio frequency identification devices in 0.3 Tesla magnetic resonance imaging and computed tomography. Thescientificworldjournal 2014: 735762, 2015