+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

A comparison between coupler gain and insertion gain of hearing aids as used in partially hearing units in five schools in Belfast



A comparison between coupler gain and insertion gain of hearing aids as used in partially hearing units in five schools in Belfast



British Journal of Audiology 23(3): 255-260



A group of 30 school-children attending partially hearing units at ordinary schools had their hearing aids assessed with reference to coupler gain and insertion gain. The results showed no statistically significant difference between the coupler and insertion gain at 250, 500 and 1000 Hz, but a small statistically significant difference with insertion gain greater at 2000, 4000 and 5000 Hz. A large individual variation in results is noted, which would suggest that a standard 2 cm3 coupler is of little use in predicting the output of an aid in a specific child's ear. The presence of wax in the ear canals seems to affect the insertion gain in a positive fashion but this is not statistically significant and further investigation is warranted.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 039047970

Download citation: RISBibTeXText

PMID: 2790312

DOI: 10.3109/03005368909076508


Related references

Insertion gain versus median ear corrected coupler gain: a comparison of two fitting methods in new NHS hearing aid users. British Journal of Audiology 32(3): 153-165, 1998

A Survey of Hearing Aids in Schools for the Deaf and Partially Hearing Units. British Journal of Audiology 3(1): 2-11, 1969

Hearing aid benefit related to the POGO amplification formula, evaluated from insertion gain measurements of two BTE hearing aids. Scandinavian Audiology 19(4): 251-256, 1990

Allowing for real ear venting effects when selecting the coupler gain of hearing aids. Ear and Hearing 12(6): 406-416, 1991

Coupler and real-ear measurement of hearing aid gain and output in the NIDCD/VA Hearing Aid Clinical Trial. Ear and Hearing 23(4): 308-315, 2002

Comparison of hearing-aid gain using functional, coupler, and probe-tube measurements. Journal of Speech and Hearing Research 29(2): 218-226, 1986

Insertion gain measurements using two low-powered analogue hearing aids. British Journal of Audiology 34(6): 375-377, 2000

Insertion Gain Measurements using Two Low-Powered Analogue Hearing Aids. British Journal of Audiology 34(6): 375-377, 2000

Hearing aid evaluation: predicting speech gain from insertion gain. Journal of Speech and Hearing Research 36(3): 621-633, 1993

The variability of functional gain and insertion gain in hearing aid fitting. Acta Otorhinolaryngologica Italica 12(2): 143-151, 1992

Preferred insertion gain of hearing aids in listening and reading-aloud situations. Journal of Speech and Hearing Research 33(3): 520-529, 1990

Reliability of real ear insertion gain in behind-the-ear hearing aids with different coupling systems to the ear canal. International Journal of Audiology 52(3): 169-176, 2013

Predicted gain and functional gain with transcranial routing of signal completely-in-the-canal hearing aids. American Journal of Audiology 12(2): 84-90, 2003

Communication methods used at schools for deaf and partially hearing children and at units for partially hearing children in the United Kingdom. American Annals of the Deaf 127(7): 811-815, 1982

Selecting the gain of hearing aids for persons with sensori neural hearing impairments. Scandinavian Audiology 5(2): 51-59, 1976